Huawei SUN2000: fix curtailed false-positive at 100% feed-in limit (#31695)

This commit is contained in:
andig 2026-07-11 23:52:48 +02:00 • committed by GitHub
parent 62ed1c4710
commit 1074db922d
No known key found for this signature in database
GPG key ID: B5690EEEBB952194

View file

@ -262,12 +262,29 @@ render: |
type: writesingle
encoding: uint16
curtailed:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 47415 # Active power control mode (0=no curtailment)
type: holding
decode: uint16
source: go
in:
- name: mode
type: int
config:
source: modbus
{{- include "modbus" . | indent 6 }}
register:
address: 47415 # Active power control mode (0=no curtailment)
type: holding
decode: uint16
- name: percent
type: int
config:
source: modbus
{{- include "modbus" . | indent 6 }}
register:
address: 47418 # Maximum Feed Grid Power (0-100 %)
type: holding
decode: uint16
scale: 0.1
# mode 7 (percentage limit) at 100% means limited-grid-connection is enabled but not actually curtailing
script: mode != 0 && !(mode == 7 && percent == 100)
{{- end }}