vw/eudataact: only use bcam threshold as target soc when care mode active (#32521)
This commit is contained in:
parent
46ff84ee3c
commit
124edaa32c
3 changed files with 33 additions and 3 deletions
|
|
@ -239,15 +239,34 @@ func TestSocBatteryStateReportOnlyFallbackField(t *testing.T) {
|
|||
|
||||
// TestGetLimitSocBcamThreshold reproduces issue #32241: the Audi Q4 e-tron
|
||||
// reports its battery care mode SoC limit only under the battery care mode
|
||||
// field, not under the generic target soc field.
|
||||
// field, not under the generic target soc field, while battery care mode is
|
||||
// active.
|
||||
func TestGetLimitSocBcamThreshold(t *testing.T) {
|
||||
data := []point{{Name: FieldChargeBcamThreshold, Value: "80"}}
|
||||
data := []point{
|
||||
{Name: FieldChargeBcamThreshold, Value: "80"},
|
||||
{Name: FieldBcamActivation, Value: BcamActivationActivated},
|
||||
}
|
||||
|
||||
limit, err := testProvider(data).GetLimitSoc()
|
||||
require.NoError(t, err)
|
||||
assert.Equal(t, int64(80), limit)
|
||||
}
|
||||
|
||||
// TestGetLimitSocBcamThresholdInactive reproduces issue #32520: with battery
|
||||
// care mode inactive, the care mode threshold is unrelated to the actual
|
||||
// target soc and must not shadow it.
|
||||
func TestGetLimitSocBcamThresholdInactive(t *testing.T) {
|
||||
data := []point{
|
||||
{Name: FieldTargetSoc, Value: "100"},
|
||||
{Name: FieldChargeBcamThreshold, Value: "80"},
|
||||
{Name: FieldBcamActivation, Value: "BCAM_ACTIVATION_DEACTIVATED"},
|
||||
}
|
||||
|
||||
limit, err := testProvider(data).GetLimitSoc()
|
||||
require.NoError(t, err)
|
||||
assert.Equal(t, int64(100), limit)
|
||||
}
|
||||
|
||||
// TestPoints guards that a data point with a generic field name ("value") is
|
||||
// stored once yet found by both its unique key and its name.
|
||||
func TestPoints(t *testing.T) {
|
||||
|
|
|
|||
|
|
@ -188,7 +188,14 @@ func (v *Provider) GetLimitSoc() (int64, error) {
|
|||
return 0, err
|
||||
}
|
||||
|
||||
if p := lookup(data, FieldTargetSoc, FieldChargeBcamThreshold); p != nil {
|
||||
// the battery care mode threshold only reflects the target soc while care
|
||||
// mode is active; otherwise it is unrelated and must not be used (see #32520)
|
||||
fields := []string{FieldTargetSoc}
|
||||
if p := find(data, FieldBcamActivation); p != nil && p.Value == BcamActivationActivated {
|
||||
fields = append(fields, FieldChargeBcamThreshold)
|
||||
}
|
||||
|
||||
if p := lookup(data, fields...); p != nil {
|
||||
f, err := strconv.ParseFloat(p.Value, 64)
|
||||
return int64(f), err
|
||||
}
|
||||
|
|
|
|||
|
|
@ -132,6 +132,10 @@ const (
|
|||
// target soc
|
||||
FieldTargetSoc = "settings.target_soc"
|
||||
FieldChargeBcamThreshold = "battery_care_mode.charge_bcam_threshold" // Audi Q4 e-tron battery care mode target soc
|
||||
FieldBcamActivation = "setting.bcam_activation" // only equals target soc while battery care mode is active
|
||||
|
||||
// battery care mode activation values (see FieldBcamActivation)
|
||||
BcamActivationActivated = "BCAM_ACTIVATION_ACTIVATED"
|
||||
|
||||
// range
|
||||
FieldRangeCombined = "cruising_range_combined"
|
||||
|
|
|
|||
Loading…