Ignore negative PV power for homePower (#2117)
Positive power means it is an energy source, negative power means it is a consumer. When calculating homePower only energy sources may be considered, hence negative PV power needs to be ignored
This commit is contained in:
parent
3c9b6a263d
commit
184065152e
1 changed files with 2 additions and 1 deletions
|
|
@ -404,7 +404,8 @@ func (site *Site) update(lp Updater) {
|
|||
if sitePower, err := site.sitePower(); err == nil {
|
||||
lp.Update(sitePower, cheap, site.batteryBuffered)
|
||||
|
||||
homePower := site.gridPower + site.pvPower + site.batteryPower
|
||||
// ignore negative pvPower values as that means it is not an energy source but consumption
|
||||
homePower := site.gridPower + math.Max(0, site.pvPower) + site.batteryPower
|
||||
for _, lp := range site.loadpoints {
|
||||
homePower -= lp.GetChargePower()
|
||||
}
|
||||
|
|
|
|||