Mbmd: support non-Sunspec meters using ModbusTCP (#3354)
This commit is contained in:
parent
a7f9f8bfda
commit
1aaa80e69b
5 changed files with 82 additions and 5 deletions
|
|
@ -7,10 +7,11 @@ params:
|
|||
- name: usage
|
||||
choice: ["grid", "pv", "battery", "charge"]
|
||||
- name: modbus
|
||||
choice: ["tcpip"]
|
||||
choice: ["rs485", "tcpip"]
|
||||
render: |
|
||||
type: modbus
|
||||
model: cgem24
|
||||
{{- include "modbus" . }}
|
||||
{{- if eq .usage "charge" }}
|
||||
energy: Import # only required for charge meter usage
|
||||
{{- end }}
|
||||
|
|
@ -20,4 +21,3 @@ render: |
|
|||
- CurrentL2
|
||||
- CurrentL3
|
||||
{{- end }}
|
||||
{{- include "modbus" . }}
|
||||
|
|
|
|||
|
|
@ -7,12 +7,13 @@ params:
|
|||
- name: usage
|
||||
choice: ["grid", "pv", "battery", "charge"]
|
||||
- name: modbus
|
||||
choice: ["rs485"]
|
||||
choice: ["rs485", "tcpip"]
|
||||
render: |
|
||||
type: modbus
|
||||
model: pac2200
|
||||
{{- include "modbus" . }}
|
||||
{{- if eq .usage "charge" }}
|
||||
energy: Sum # only required for charge meter usage
|
||||
energy: Import # only required for charge meter usage
|
||||
{{- end }}
|
||||
{{- if or (eq .usage "charge") (eq .usage "grid") }}
|
||||
currents:
|
||||
|
|
@ -20,4 +21,3 @@ render: |
|
|||
- CurrentL2
|
||||
- CurrentL3
|
||||
{{- end }}
|
||||
{{- include "modbus" . }}
|
||||
|
|
|
|||
|
|
@ -8,6 +8,19 @@ render:
|
|||
template: cg-em24
|
||||
usage: grid
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
|
|
@ -19,6 +32,19 @@ render:
|
|||
template: cg-em24
|
||||
usage: pv
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
|
|
@ -30,6 +56,19 @@ render:
|
|||
template: cg-em24
|
||||
usage: battery
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
|
|
@ -41,6 +80,19 @@ render:
|
|||
template: cg-em24
|
||||
usage: charge
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
|
|
|
|||
|
|
@ -20,6 +20,12 @@ render:
|
|||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
- usage: pv
|
||||
default: |
|
||||
type: template
|
||||
|
|
@ -38,6 +44,12 @@ render:
|
|||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
- usage: battery
|
||||
default: |
|
||||
type: template
|
||||
|
|
@ -56,6 +68,12 @@ render:
|
|||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
- usage: charge
|
||||
default: |
|
||||
type: template
|
||||
|
|
@ -74,3 +92,9 @@ render:
|
|||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
|
|||
|
|
@ -14,5 +14,6 @@ rtu: true
|
|||
{{- if or (eq .modbus "tcpip") .tcpip }}
|
||||
# Modbus TCP
|
||||
uri: {{ .host }}:{{ .port }}
|
||||
rtu: false
|
||||
{{- end }}
|
||||
{{- end}}
|
||||
|
|
|
|||