Atmoce: add curtail and dimming, add holdcharge and rework normal/hold/charge (#31632)
This commit is contained in:
parent
8b243c2a25
commit
20a1c0886e
1 changed files with 305 additions and 42 deletions
|
|
@ -3,13 +3,17 @@ products:
|
|||
- brand: Atmoce
|
||||
description:
|
||||
generic: MG100 M-gateway
|
||||
capabilities: ["battery-control"]
|
||||
capabilities: ["battery-control", "curtail", "dim"]
|
||||
requirements:
|
||||
description:
|
||||
de: |
|
||||
Unterstützung für Atmoce MG100 (im Lieferumfang von MC100 und MC100-T enthalten). Erfordert, dass der Installateur Modbus TCP in der Konfiguration aktiviert; verfügbar ab Firmware-Version 01.01.00.18.10.
|
||||
Unterstützung für Atmoce MG100 (im Lieferumfang von MC100 und MC100-T enthalten).
|
||||
Der Installateur muss Modbus TCP in der Konfiguration oder über die Atmozen-App aktivieren; verfügbar ab Firmware-Version 01.01.00.18.10.
|
||||
Die Funktionen 'Netzaufladung' und 'Export von Leistung ins Netz' müssen in der Atmozen-App aktiviert sein, um das Laden/Entladen des Akkus aus dem Netz zu ermöglichen.
|
||||
en: |
|
||||
Support for Atmoce MG100 (included with MC100 and MC100-T). Requires installer to enable Modbus TCP in configuration; available in firmware 01.01.00.18.10 or later.
|
||||
Support for Atmoce MG100 (included with MC100 and MC100-T).
|
||||
Requires installer to enable Modbus TCP in configuration or through Atmozen app; available in firmware 01.01.00.18.10 or later.
|
||||
'Grid Recharging' and 'Export Power' must be enabled in the Atmozen app to allow battery (dis)charging to/from grid.
|
||||
params:
|
||||
- name: usage
|
||||
choice: ["grid", "pv", "battery"]
|
||||
|
|
@ -17,6 +21,7 @@ params:
|
|||
choice: ["tcpip"]
|
||||
id: 1
|
||||
- name: maxacpower
|
||||
service: modbus/read?address=60027&type=holding&encoding=uint32&scale=1&resulttype=int&{modbus}
|
||||
- preset: battery-params
|
||||
- name: capacity
|
||||
service: modbus/read?address=60031&type=holding&encoding=uint32&scale=0.001&resulttype=int&{modbus}
|
||||
|
|
@ -26,6 +31,23 @@ params:
|
|||
- name: maxsoc
|
||||
advanced: true
|
||||
default: 100
|
||||
- name: maxdischargepower
|
||||
service: modbus/read?address=60029&type=holding&encoding=uint32&scale=1&resulttype=int&{modbus}
|
||||
- name: firmware
|
||||
type: choice
|
||||
choice: ["<01.01.00.28.15", ">=01.01.00.28.15"]
|
||||
default: "<01.01.00.28.15"
|
||||
advanced: true
|
||||
description:
|
||||
de: Firmware-Version
|
||||
en: Firmware version
|
||||
help:
|
||||
de: |
|
||||
Firmware 01.01.00.28.15 und höher ermöglichen die korrekte Hold/Holdcharge-Funktionalität sowie das Dimmen und Abschalten.
|
||||
Ältere Versionen unterstützen lediglich die Hold-Funktion ohne (Ent-)Ladefunktion.
|
||||
en: |
|
||||
Firmware 01.01.00.28.15 and higher allows for correct hold/holdcharge functionality, dimming and curtailing.
|
||||
Older versions only support hold function without (dis)charge.
|
||||
render: |
|
||||
type: custom
|
||||
{{- if eq .usage "grid" }}
|
||||
|
|
@ -116,6 +138,56 @@ render: |
|
|||
decode: uint64
|
||||
scale: 0.01
|
||||
maxacpower: {{ .maxacpower }}
|
||||
{{- if not ( eq .firmware "<01.01.00.28.15" ) }}
|
||||
curtail:
|
||||
source: switch
|
||||
switch:
|
||||
- case: 100 # No curtailment
|
||||
set:
|
||||
source: const
|
||||
value: 0xFFFFFFFF # No limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 60322 # Photovoltaic Maximum Power (kW * 1000)
|
||||
type: writemultiple
|
||||
encoding: uint32
|
||||
default:
|
||||
source: go
|
||||
in:
|
||||
- name: maxacpower
|
||||
type: int
|
||||
config:
|
||||
source: const
|
||||
value: {{ .maxacpower }}
|
||||
script: |
|
||||
powerlimit := ( maxacpower * curtail ) / 100
|
||||
powerlimit
|
||||
out:
|
||||
- name: powerlimit
|
||||
type: int
|
||||
config:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 60322 # Photovoltaic Maximum Power (kW * 1000)
|
||||
type: writemultiple
|
||||
encoding: uint32
|
||||
curtailed:
|
||||
source: go
|
||||
in:
|
||||
- name: limit
|
||||
type: int
|
||||
config:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 8 }}
|
||||
register:
|
||||
address: 60322 # Photovoltaic Maximum Power (kW * 1000)
|
||||
type: holding
|
||||
decode: uint32
|
||||
script: limit != 0xFFFFFFFF
|
||||
{{- end }}
|
||||
{{- end }}
|
||||
{{- if eq .usage "battery" }}
|
||||
power:
|
||||
|
|
@ -153,58 +225,249 @@ render: |
|
|||
batterymode:
|
||||
source: switch
|
||||
switch:
|
||||
- case: 1 # normal
|
||||
- case: 1 # normal
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: 2
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
{{- if eq .firmware ">=01.01.00.28.15" }}
|
||||
- source: const
|
||||
value: 0xFFFFFFFF # No limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60318 # Energy Storage Maximum Charging Power (kW * 1000)
|
||||
type: writemultiple
|
||||
decode: uint32
|
||||
- source: const
|
||||
value: 0xFFFFFFFF # No limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60320 # Energy Storage Maximum Discharging Power (kW * 1000)
|
||||
type: writemultiple
|
||||
decode: uint32
|
||||
{{- end }}
|
||||
- case: 2 # hold -> No discharging
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: {{ if eq .firmware "<01.01.00.28.15" }}99{{ else }}2{{ end }}
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
{{- if eq .firmware ">=01.01.00.28.15" }}
|
||||
- source: const
|
||||
value: 0xFFFFFFFF # No limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60318 # Energy Storage Maximum Charging Power (kW * 1000)
|
||||
type: writemultiple
|
||||
decode: uint32
|
||||
- source: const
|
||||
value: 0 # Set discharge limit to 0W
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60320 # Energy Storage Maximum Discharging Power (kW * 1000)
|
||||
type: writemultiple
|
||||
decode: uint32
|
||||
{{- end }}
|
||||
- case: 3 # charge -> Enable grid charging with maximum target soc (will be stopped by evcc)
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: {{ .maxsoc }}
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60312 # Energy Storage Forced Charging/Discharging Target SOC (%)
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
- source: const
|
||||
value: 0
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60311 # Energy Storage Forced Charging/Discharging Mode (0 = Target SOC, 1 = Charging/discharging duration)
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
- source: const
|
||||
value: 0
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
{{- if eq .firmware ">=01.01.00.28.15" }}
|
||||
- source: const
|
||||
value: 0xFFFFFFFF # No limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60318 # Energy Storage Maximum Charging Power (kW * 1000)
|
||||
type: writemultiple
|
||||
decode: uint32
|
||||
- source: const
|
||||
value: 0xFFFFFFFF # No limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60320 # Energy Storage Maximum Discharging Power (kW * 1000)
|
||||
type: writemultiple
|
||||
decode: uint32
|
||||
{{- end }}
|
||||
- case: 4 # holdcharge -> No charging
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
{{- if eq .firmware ">=01.01.00.28.15" }}
|
||||
- source: const
|
||||
value: 2
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
- source: const
|
||||
value: 0 # Set charge limit to 0W
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60318 # Energy Storage Maximum Charging Power (kW * 1000)
|
||||
type: writemultiple
|
||||
decode: uint32
|
||||
- source: const
|
||||
value: 0xFFFFFFFF # No limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 60320 # Energy Storage Maximum Discharging Power (kW * 1000)
|
||||
type: writemultiple
|
||||
decode: uint32
|
||||
{{- else }}
|
||||
- source: sleep
|
||||
duration: 0s
|
||||
{{- end }}
|
||||
{{- if not ( eq .firmware "<01.01.00.28.15" ) }}
|
||||
curtail:
|
||||
source: switch
|
||||
switch:
|
||||
- case: 100 # No curtailment
|
||||
set:
|
||||
source: const
|
||||
value: 0xFFFFFFFF # No limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 60324 # Grid Maximum Export Power (kW * 1000)
|
||||
type: writemultiple
|
||||
encoding: uint32
|
||||
default:
|
||||
source: go
|
||||
in:
|
||||
- name: maxdischargepower
|
||||
type: int
|
||||
config:
|
||||
source: const
|
||||
value: {{ .maxdischargepower }}
|
||||
script: |
|
||||
powerlimit := ( maxdischargepower * curtail ) / 100
|
||||
powerlimit
|
||||
out:
|
||||
- name: powerlimit
|
||||
type: int
|
||||
config:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 60324 # Grid Maximum Export Power (kW * 1000)
|
||||
type: writemultiple
|
||||
encoding: uint32
|
||||
curtailed:
|
||||
source: go
|
||||
in:
|
||||
- name: limit
|
||||
type: int
|
||||
config:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 8 }}
|
||||
register:
|
||||
address: 60324 # Grid Maximum Export Power (kW * 1000)
|
||||
type: holding
|
||||
decode: uint32
|
||||
script: limit != 0xFFFFFFFF
|
||||
dim:
|
||||
source: ifelse
|
||||
if:
|
||||
source: convert
|
||||
convert: bool2int
|
||||
set:
|
||||
source: const
|
||||
value: 2
|
||||
value: 0 # Set grid import limit to 0W
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 8 }}
|
||||
register:
|
||||
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
||||
address: 60326 # Grid Maximum Import Power (kW * 1000)
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
- case: 2 # hold -> Pause charge/discharge
|
||||
encoding: uint32
|
||||
else:
|
||||
source: convert
|
||||
convert: bool2int
|
||||
set:
|
||||
source: const
|
||||
value: 99
|
||||
value: 0xFFFFFFFF # No limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 8 }}
|
||||
register:
|
||||
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
||||
address: 60326 # Grid Maximum Import Power (kW * 1000)
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
- case: 3 # charge -> Enable grid charging with maximum target soc (will be stopped by evcc)
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: {{ .maxsoc }}
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 60312 # Energy Storage Forced Charging/Discharging Target SOC
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
- source: const
|
||||
value: 0
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 60311 # Energy Storage Forced Charging/Discharging Mode (0 = Target SOC, 1 = Charging/discharging duration)
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
- source: const
|
||||
value: 0
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 60310 # Energy Storage Forced Charging/Discharging (0 = Forced charging, 1 = Forced discharging, 2 = Exit forced charging/discharging, 99 = Pause)
|
||||
type: writemultiple
|
||||
decode: uint16
|
||||
encoding: uint32
|
||||
dimmed:
|
||||
source: go
|
||||
in:
|
||||
- name: limit
|
||||
type: int
|
||||
config:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 8 }}
|
||||
register:
|
||||
address: 60326 # Grid Maximum Import Power (kW * 1000)
|
||||
type: holding
|
||||
decode: uint32
|
||||
script: limit == 0
|
||||
{{- end }}
|
||||
{{- include "battery-params" . }}
|
||||
{{- end }}
|
||||
|
|
|
|||