@ -1332,7 +1332,11 @@ func (lp *Loadpoint) boostPower(batteryBoostPower float64) float64 {
|
|||
delta := math.Max(100, math.Abs(lp.site.GetResidualPower()))
|
||||
|
||||
if lp.coarseCurrent() {
|
||||
delta = math.Max(delta, lp.EffectiveStepPower())
|
||||
// add effective step power to delta to make sure to step up to the next full amp
|
||||
// just using lp.EffectiveStepPower() as delta is not enough because this will result
|
||||
// in a too low current when there is a bit remaining grid consumption due to the accuracy
|
||||
// of the battery controller
|
||||
delta += lp.EffectiveStepPower()
|
||||
}
|
||||
|
||||
// start boosting by setting maximum power
|
||||
|
|
|
|||