EEBus: drop redundant Scenario middle word from constant names (#29704)
This commit is contained in:
parent
4b276a4d99
commit
2a496683ca
3 changed files with 49 additions and 49 deletions
|
|
@ -11,62 +11,62 @@ package eebus
|
|||
|
||||
// MGCP — Monitoring of Grid Connection Point (UC TS v1.0.0)
|
||||
const (
|
||||
MGCPScenarioPowerFactor uint = 1 // S1 power factor (cos phi)
|
||||
MGCPScenarioPower uint = 2 // S2 active power per phase + total
|
||||
MGCPScenarioEnergyFeedIn uint = 3 // S3 total feed-in energy
|
||||
MGCPScenarioEnergyConsumed uint = 4 // S4 total consumed energy
|
||||
MGCPScenarioCurrentPerPhase uint = 5 // S5 phase-specific currents
|
||||
MGCPScenarioVoltagePerPhase uint = 6 // S6 phase-specific voltages
|
||||
MGCPScenarioFrequency uint = 7 // S7 frequency
|
||||
MGCPPowerFactor uint = 1 // S1 power factor (cos phi)
|
||||
MGCPPower uint = 2 // S2 active power per phase + total
|
||||
MGCPEnergyFeedIn uint = 3 // S3 total feed-in energy
|
||||
MGCPEnergyConsumed uint = 4 // S4 total consumed energy
|
||||
MGCPCurrentPerPhase uint = 5 // S5 phase-specific currents
|
||||
MGCPVoltagePerPhase uint = 6 // S6 phase-specific voltages
|
||||
MGCPFrequency uint = 7 // S7 frequency
|
||||
)
|
||||
|
||||
// MPC — Monitoring of Power Consumption (UC TS v1.0.0)
|
||||
const (
|
||||
MPCScenarioPower uint = 1 // S1 active power per phase + total
|
||||
MPCScenarioEnergyConsumed uint = 2 // S2 total consumed energy
|
||||
MPCScenarioCurrentPerPhase uint = 3 // S3 phase-specific currents
|
||||
MPCScenarioVoltagePerPhase uint = 4 // S4 phase-specific voltages
|
||||
MPCScenarioFrequency uint = 5 // S5 frequency
|
||||
MPCPower uint = 1 // S1 active power per phase + total
|
||||
MPCEnergyConsumed uint = 2 // S2 total consumed energy
|
||||
MPCCurrentPerPhase uint = 3 // S3 phase-specific currents
|
||||
MPCVoltagePerPhase uint = 4 // S4 phase-specific voltages
|
||||
MPCFrequency uint = 5 // S5 frequency
|
||||
)
|
||||
|
||||
// LPC — Limitation of Power Consumption (UC TS v1.0.0). Same scenario layout for CS and EG roles.
|
||||
const (
|
||||
LPCScenarioLimit uint = 1 // S1 LoadControl: consumption limit
|
||||
LPCScenarioFailsafe uint = 2 // S2 DeviceConfiguration: failsafe values
|
||||
LPCScenarioHeartbeat uint = 3 // S3 DeviceDiagnosis: heartbeat
|
||||
LPCScenarioElectricalConnection uint = 4 // S4 ElectricalConnection (optional)
|
||||
LPCLimit uint = 1 // S1 LoadControl: consumption limit
|
||||
LPCFailsafe uint = 2 // S2 DeviceConfiguration: failsafe values
|
||||
LPCHeartbeat uint = 3 // S3 DeviceDiagnosis: heartbeat
|
||||
LPCElectricalConnection uint = 4 // S4 ElectricalConnection (optional)
|
||||
)
|
||||
|
||||
// LPP — Limitation of Power Production (UC TS v1.0.0). Same scenario layout for CS and EG roles.
|
||||
const (
|
||||
LPPScenarioLimit uint = 1 // S1 LoadControl: production limit
|
||||
LPPScenarioFailsafe uint = 2 // S2 DeviceConfiguration: failsafe values
|
||||
LPPScenarioHeartbeat uint = 3 // S3 DeviceDiagnosis: heartbeat
|
||||
LPPScenarioElectricalConnection uint = 4 // S4 ElectricalConnection (optional)
|
||||
LPPLimit uint = 1 // S1 LoadControl: production limit
|
||||
LPPFailsafe uint = 2 // S2 DeviceConfiguration: failsafe values
|
||||
LPPHeartbeat uint = 3 // S3 DeviceDiagnosis: heartbeat
|
||||
LPPElectricalConnection uint = 4 // S4 ElectricalConnection (optional)
|
||||
)
|
||||
|
||||
// OPEV — Overload Protection by EV Charging Current Curtailment (UC TS v1.0.1)
|
||||
const (
|
||||
OPEVScenarioObligationLimit uint = 1 // S1 LoadControl + ElectricalConnection
|
||||
OPEVScenarioChargingState uint = 2 // S2 charging state
|
||||
OPEVScenarioChargingPlan uint = 3 // S3 charging plan
|
||||
OPEVObligationLimit uint = 1 // S1 LoadControl + ElectricalConnection
|
||||
OPEVChargingState uint = 2 // S2 charging state
|
||||
OPEVChargingPlan uint = 3 // S3 charging plan
|
||||
)
|
||||
|
||||
// OSCEV — Optimization of Self-Consumption during EV Charging (UC TS v1.0.1)
|
||||
const (
|
||||
OSCEVScenarioRecommendationLimit uint = 1 // S1 LoadControl + ElectricalConnection
|
||||
OSCEVScenarioChargingState uint = 2 // S2 charging state
|
||||
OSCEVScenarioChargingPlan uint = 3 // S3 charging plan
|
||||
OSCEVRecommendationLimit uint = 1 // S1 LoadControl + ElectricalConnection
|
||||
OSCEVChargingState uint = 2 // S2 charging state
|
||||
OSCEVChargingPlan uint = 3 // S3 charging plan
|
||||
)
|
||||
|
||||
// EVCEM — Measurement of Electricity during EV Charging (UC TS v1.0.1)
|
||||
const (
|
||||
EVCEMScenarioPowerPerPhase uint = 1 // S1 phase-specific active power + ElectricalConnection (currents)
|
||||
EVCEMScenarioPowerTotal uint = 2 // S2 total active power only
|
||||
EVCEMScenarioEnergy uint = 3 // S3 charging energy summary
|
||||
EVCEMPowerPerPhase uint = 1 // S1 phase-specific active power + ElectricalConnection (currents)
|
||||
EVCEMPowerTotal uint = 2 // S2 total active power only
|
||||
EVCEMEnergy uint = 3 // S3 charging energy summary
|
||||
)
|
||||
|
||||
// EVSOC — EV State of Charge (UC TS v1.0.0 RC1)
|
||||
const (
|
||||
EVSOCScenarioStateOfCharge uint = 1 // S1 state of charge
|
||||
EVSOCStateOfCharge uint = 1 // S1 state of charge
|
||||
)
|
||||
|
|
|
|||
Loading…