Senergy-hybrid: fix template (#26065)
This commit is contained in:
parent
236cde95bf
commit
3087ce8d8b
1 changed files with 138 additions and 27 deletions
|
|
@ -15,21 +15,42 @@ params:
|
|||
id: 1
|
||||
- name: capacity
|
||||
advanced: true
|
||||
- name: maxchargepower
|
||||
default: 10000
|
||||
- name: maxdischargepower
|
||||
default: 10000
|
||||
- name: minsoc
|
||||
advanced: true
|
||||
default: 10
|
||||
- name: maxsoc
|
||||
advanced: true
|
||||
default: 100
|
||||
- name: maxacpower
|
||||
render: |
|
||||
type: custom
|
||||
{{- if eq .usage "grid" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 0x1066 # Grid Total Power
|
||||
type: holding
|
||||
decode: int32
|
||||
source: calc
|
||||
add:
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 4 }}
|
||||
register:
|
||||
address: 0x1300 # L1 watt of grid
|
||||
type: holding
|
||||
decode: int32
|
||||
scale: 0.1
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 4 }}
|
||||
register:
|
||||
address: 0x1302 # L2 watt of grid
|
||||
type: holding
|
||||
decode: int32
|
||||
scale: 0.1
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 4 }}
|
||||
register:
|
||||
address: 0x1304 # L3 watt of grid
|
||||
type: holding
|
||||
decode: int32
|
||||
scale: 0.1
|
||||
energy:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
|
|
@ -45,21 +66,21 @@ render: |
|
|||
address: 0x131D # Grid Phase A Current
|
||||
type: holding
|
||||
decode: int32
|
||||
scale: 100
|
||||
scale: 0.01
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 4 }}
|
||||
register:
|
||||
address: 0x131F # Grid Phase B Current
|
||||
type: holding
|
||||
decode: int32
|
||||
scale: 100
|
||||
scale: 0.01
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 4 }}
|
||||
register:
|
||||
address: 0x1321 # Grid Phase C Current
|
||||
type: holding
|
||||
decode: int32
|
||||
scale: 100
|
||||
scale: 0.01
|
||||
{{- end }}
|
||||
{{- if eq .usage "pv" }}
|
||||
power:
|
||||
|
|
@ -69,23 +90,15 @@ render: |
|
|||
address: 0x1048 # PV Total Input Power
|
||||
type: holding
|
||||
decode: uint32
|
||||
scale: 10
|
||||
scale: 0.1
|
||||
energy:
|
||||
source: calc
|
||||
add:
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 4 }}
|
||||
register:
|
||||
address: 0x1021 # Total Energy
|
||||
type: holding
|
||||
decode: uint32
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 4 }}
|
||||
register:
|
||||
address: 0x104C # Decimals of total energy
|
||||
type: holding
|
||||
decode: uint32
|
||||
scale: 0.001
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 0x1021 # Total Energy
|
||||
type: holding
|
||||
decode: uint32
|
||||
maxacpower: {{ .maxacpower }} # W
|
||||
{{- end }}
|
||||
{{- if eq .usage "battery" }}
|
||||
power:
|
||||
|
|
@ -111,7 +124,105 @@ render: |
|
|||
address: 0x2000 # Battery SOC
|
||||
type: holding
|
||||
decode: uint16
|
||||
batterymode:
|
||||
source: switch
|
||||
switch:
|
||||
- case: 1 # normal
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: 0 # Self used mode
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 0x2100 # Hybrid work mode
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 0 # disable
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 0x214C # Time-based control Enable
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- case: 2 # hold - stop battery discharge
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: 3 # Back-up mode
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 0x2100 # Hybrid work mode
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 0 # disable
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 0x214C # Time-based control Enable
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- case: 3 # charge - force battery charge
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: 1 # Every day
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 0x2101 # Once/Everyday 1
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 0x0000 # 00:00
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 0x2102 # Charge start time 1
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 0x173B # 23:59
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 0x2103 # Charge end time 1
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 0 # Self used mode
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 0x2100 # Hybrid work mode
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 1 # enable
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 0x214C # Time-based control Enable
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
capacity: {{ .capacity }} # kWh
|
||||
maxchargepower: {{ .maxchargepower }} # W
|
||||
maxdischargepower: {{ .maxdischargepower }} # W
|
||||
minsoc: {{ .minsoc }} # %
|
||||
maxsoc: {{ .maxsoc }} # %
|
||||
{{- end }}
|
||||
|
|
|
|||