@ -63,6 +63,7 @@ func (s *Settings) String() string {
|
|||
|
||||
type meterConnection struct {
|
||||
meters.Connection
|
||||
proto Protocol
|
||||
*logger
|
||||
}
|
||||
|
||||
|
|
@ -71,23 +72,28 @@ var (
|
|||
mu sync.Mutex
|
||||
)
|
||||
|
||||
func registeredConnection(key string, newConn meters.Connection) *meterConnection {
|
||||
func registeredConnection(key string, proto Protocol, newConn meters.Connection) (*meterConnection, error) {
|
||||
mu.Lock()
|
||||
defer mu.Unlock()
|
||||
|
||||
if conn, ok := connections[key]; ok {
|
||||
return conn
|
||||
if conn.proto != proto {
|
||||
return nil, fmt.Errorf("connection already registered with different protocol: %s", key)
|
||||
}
|
||||
|
||||
return conn, nil
|
||||
}
|
||||
|
||||
connection := &meterConnection{
|
||||
Connection: newConn,
|
||||
proto: proto,
|
||||
logger: new(logger),
|
||||
}
|
||||
|
||||
newConn.Logger(connection.logger)
|
||||
connections[key] = connection
|
||||
|
||||
return connection
|
||||
return connection, nil
|
||||
}
|
||||
|
||||
// NewConnection creates physical modbus device from config
|
||||
|
|
@ -111,8 +117,6 @@ func NewConnection(uri, device, comset string, baudrate int, proto Protocol, sla
|
|||
}
|
||||
|
||||
func physicalConnection(proto Protocol, cfg Settings) (*meterConnection, error) {
|
||||
var conn *meterConnection
|
||||
|
||||
if (cfg.Device != "") == (cfg.URI != "") {
|
||||
return nil, errors.New("invalid modbus configuration: must have either uri or device")
|
||||
}
|
||||
|
|
@ -131,28 +135,24 @@ func physicalConnection(proto Protocol, cfg Settings) (*meterConnection, error)
|
|||
}
|
||||
|
||||
if proto == Ascii {
|
||||
conn = registeredConnection(cfg.Device, meters.NewASCII(cfg.Device, cfg.Baudrate, cfg.Comset))
|
||||
return registeredConnection(cfg.Device, Ascii, meters.NewASCII(cfg.Device, cfg.Baudrate, cfg.Comset))
|
||||
} else {
|
||||
conn = registeredConnection(cfg.Device, meters.NewRTU(cfg.Device, cfg.Baudrate, cfg.Comset))
|
||||
return registeredConnection(cfg.Device, Rtu, meters.NewRTU(cfg.Device, cfg.Baudrate, cfg.Comset))
|
||||
}
|
||||
}
|
||||
|
||||
if cfg.URI != "" {
|
||||
cfg.URI = util.DefaultPort(cfg.URI, 502)
|
||||
uri := util.DefaultPort(cfg.URI, 502)
|
||||
|
||||
switch proto {
|
||||
case Udp:
|
||||
conn = registeredConnection(cfg.URI, meters.NewRTUOverUDP(cfg.URI))
|
||||
case Rtu:
|
||||
conn = registeredConnection(cfg.URI, meters.NewRTUOverTCP(cfg.URI))
|
||||
case Ascii:
|
||||
conn = registeredConnection(cfg.URI, meters.NewASCIIOverTCP(cfg.URI))
|
||||
default:
|
||||
conn = registeredConnection(cfg.URI, meters.NewTCP(cfg.URI))
|
||||
}
|
||||
switch proto {
|
||||
case Udp:
|
||||
return registeredConnection(uri, Udp, meters.NewRTUOverUDP(uri))
|
||||
case Rtu:
|
||||
return registeredConnection(uri, Rtu, meters.NewRTUOverTCP(uri))
|
||||
case Ascii:
|
||||
return registeredConnection(uri, Ascii, meters.NewASCIIOverTCP(uri))
|
||||
default:
|
||||
return registeredConnection(uri, Tcp, meters.NewTCP(uri))
|
||||
}
|
||||
|
||||
return conn, nil
|
||||
}
|
||||
|
||||