Docs: localize documentation templates (#9508)
This commit is contained in:
parent
3428a7615a
commit
36e2109770
268 changed files with 34 additions and 8984 deletions
3
.gitignore
vendored
3
.gitignore
vendored
|
|
@ -13,6 +13,7 @@ __debug_bin
|
|||
!package*.json
|
||||
!evcc.dist.yaml
|
||||
!tests/**/*.evcc.yaml
|
||||
/templates/docs
|
||||
evcc
|
||||
evcc.exe
|
||||
evcc_*
|
||||
|
|
@ -35,4 +36,4 @@ QEMU_EFI.fd
|
|||
asset-stats.html
|
||||
/test-results/
|
||||
/playwright-report/
|
||||
/playwright/.cache/
|
||||
/playwright/.cache/
|
||||
|
|
@ -1,30 +0,0 @@
|
|||
product:
|
||||
brand: ABB
|
||||
description: Terra AC
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Erfordert Firmware >= 1.6.5
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: abb
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,25 +0,0 @@
|
|||
product:
|
||||
brand: ABL
|
||||
description: eM4 (SBCx)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: abl-em4
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 255
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
advanced: |
|
||||
type: template
|
||||
template: abl-em4
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 255
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
connector: 1 # Optional
|
||||
|
|
@ -1,39 +0,0 @@
|
|||
product:
|
||||
brand: ABL
|
||||
description: eMH1, eMH2
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: abl
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 38400 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8E1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
advanced: |
|
||||
type: template
|
||||
template: abl
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 38400 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8E1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
timeout: 10s # Optional
|
||||
|
|
@ -1,39 +0,0 @@
|
|||
product:
|
||||
brand: SENEC
|
||||
description: Wallbox pro
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: abl
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 38400 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8E1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
advanced: |
|
||||
type: template
|
||||
template: abl
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 38400 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8E1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
timeout: 10s # Optional
|
||||
|
|
@ -1,17 +0,0 @@
|
|||
product:
|
||||
brand: Alfen
|
||||
description: Eve
|
||||
capabilities: ["1p3p", "mA"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Die "Active load balancing" Lizenz wird benötigt um die Wallbox via Modbus extern zu steuern. In den Einstellungen muss "Active Load Balancing" aktiviert und "Energy Management System" als Data Source ausgewählt werden. Falls die "Double"-Box verwendet wird müssen beide Ladepunkte getrennt voneinander hinzugefügt werden. Der erste Port (oder einzelne Port) ist unter ID 1 zugänglich, der zweite unter ID 2.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: alfen
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,38 +0,0 @@
|
|||
product:
|
||||
brand: Alphatec
|
||||
description: Wallbox Mini/ AW1eM
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: alphatec
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
advanced: |
|
||||
type: template
|
||||
template: alphatec
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
timeout: 10s # Optional
|
||||
|
|
@ -1,14 +0,0 @@
|
|||
product:
|
||||
brand: Mennekes
|
||||
description: AMTRON XTRA, AMTRON PREMIUM
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: amtron
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 255
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Bender
|
||||
description: CC612/613
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der 'Modbus TCP Server für Energiemanagement-Systeme' muss aktiviert sein. 'Registersatz' darf NICHT auf 'Phoenix' oder 'TQ-DM100' eingestellt sein. Die dritte Auswahlmöglichkeit 'Ebee', 'Bender', 'MENNEKES' etc. ist richtig. 'UID Übertragung erlauben' muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: bender
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Mennekes
|
||||
description: Amedio, Amtron ChargeControl, Professional
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der 'Modbus TCP Server für Energiemanagement-Systeme' muss aktiviert sein. 'Registersatz' darf NICHT auf 'Phoenix' oder 'TQ-DM100' eingestellt sein. Die dritte Auswahlmöglichkeit 'Ebee', 'Bender', 'MENNEKES' etc. ist richtig. 'UID Übertragung erlauben' muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: bender
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Webasto
|
||||
description: Live
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der 'Modbus TCP Server für Energiemanagement-Systeme' muss aktiviert sein. 'Registersatz' darf NICHT auf 'Phoenix' oder 'TQ-DM100' eingestellt sein. Die dritte Auswahlmöglichkeit 'Ebee', 'Bender', 'MENNEKES' etc. ist richtig. 'UID Übertragung erlauben' muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: bender
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Juice
|
||||
description: Charger Me
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der 'Modbus TCP Server für Energiemanagement-Systeme' muss aktiviert sein. 'Registersatz' darf NICHT auf 'Phoenix' oder 'TQ-DM100' eingestellt sein. Die dritte Auswahlmöglichkeit 'Ebee', 'Bender', 'MENNEKES' etc. ist richtig. 'UID Übertragung erlauben' muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: bender
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: TechniSat
|
||||
description: Technivolt
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der 'Modbus TCP Server für Energiemanagement-Systeme' muss aktiviert sein. 'Registersatz' darf NICHT auf 'Phoenix' oder 'TQ-DM100' eingestellt sein. Die dritte Auswahlmöglichkeit 'Ebee', 'Bender', 'MENNEKES' etc. ist richtig. 'UID Übertragung erlauben' muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: bender
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Ebee
|
||||
description: Wallbox
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der 'Modbus TCP Server für Energiemanagement-Systeme' muss aktiviert sein. 'Registersatz' darf NICHT auf 'Phoenix' oder 'TQ-DM100' eingestellt sein. Die dritte Auswahlmöglichkeit 'Ebee', 'Bender', 'MENNEKES' etc. ist richtig. 'UID Übertragung erlauben' muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: bender
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Optec
|
||||
description: Mobility One
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der 'Modbus TCP Server für Energiemanagement-Systeme' muss aktiviert sein. 'Registersatz' darf NICHT auf 'Phoenix' oder 'TQ-DM100' eingestellt sein. Die dritte Auswahlmöglichkeit 'Ebee', 'Bender', 'MENNEKES' etc. ist richtig. 'UID Übertragung erlauben' muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: bender
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Garo
|
||||
description: GLB, GLB+, LS4, LS4 compact
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der 'Modbus TCP Server für Energiemanagement-Systeme' muss aktiviert sein. 'Registersatz' darf NICHT auf 'Phoenix' oder 'TQ-DM100' eingestellt sein. Die dritte Auswahlmöglichkeit 'Ebee', 'Bender', 'MENNEKES' etc. ist richtig. 'UID Übertragung erlauben' muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: bender
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Ensto
|
||||
description: Chago Wallbox
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der 'Modbus TCP Server für Energiemanagement-Systeme' muss aktiviert sein. 'Registersatz' darf NICHT auf 'Phoenix' oder 'TQ-DM100' eingestellt sein. Die dritte Auswahlmöglichkeit 'Ebee', 'Bender', 'MENNEKES' etc. ist richtig. 'UID Übertragung erlauben' muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: bender
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Ubitricity
|
||||
description: Heinz
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der 'Modbus TCP Server für Energiemanagement-Systeme' muss aktiviert sein. 'Registersatz' darf NICHT auf 'Phoenix' oder 'TQ-DM100' eingestellt sein. Die dritte Auswahlmöglichkeit 'Ebee', 'Bender', 'MENNEKES' etc. ist richtig. 'UID Übertragung erlauben' muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: bender
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,12 +0,0 @@
|
|||
product:
|
||||
brand: cFos
|
||||
description: PowerBrain
|
||||
capabilities: ["mA", "rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der Zähler- falls vorhanden- muss separat als Ladezähler konfiguriert werden.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: cfos
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,14 +0,0 @@
|
|||
product:
|
||||
brand: Dadapower
|
||||
description: Premium Wallbox
|
||||
capabilities: ["1p3p", "mA", "rfid"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: dadapower
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,11 +0,0 @@
|
|||
product:
|
||||
brand: DaheimLaden
|
||||
description: Wallbox (via ModbusTCP)
|
||||
description: |
|
||||
Für die Nutzung mit evcc muss die Wallbox mit einer aktuellen Firmware mit Modbus-Unterstützung betrieben werden. Bitte mit dem Hersteller abklären.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: daheimladen-mb
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,11 +0,0 @@
|
|||
product:
|
||||
brand: DaheimLaden
|
||||
description: Wallbox
|
||||
description: |
|
||||
Für die Nutzung mit evcc muss die Wallbox im RFID Modus betrieben werden.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: daheimladen
|
||||
token: # Sie bekommen dieses Access Token vom Daheimladen Support: info@daheimladen.de. (Optional)
|
||||
stationid: # Die Seriennummer, welche auf dem Bildschirm der Wallbox angezeigt wird. (Optional)
|
||||
|
|
@ -1,19 +0,0 @@
|
|||
product:
|
||||
brand: Easee
|
||||
description: Home
|
||||
capabilities: ["1p3p", "rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: easee
|
||||
user: # Emailadresse
|
||||
password: # wie Login für Easee App oder Web Portal (https://easee.cloud)
|
||||
charger: EH______
|
||||
advanced: |
|
||||
type: template
|
||||
template: easee
|
||||
user: # Emailadresse
|
||||
password: # wie Login für Easee App oder Web Portal (https://easee.cloud)
|
||||
charger: EH______
|
||||
timeout: 10s # Optional
|
||||
|
|
@ -1,11 +0,0 @@
|
|||
product:
|
||||
description: EEBUS kompatible Wallbox
|
||||
group: Generische Unterstützung
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: eebus
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse (Optional)
|
||||
|
|
@ -1,20 +0,0 @@
|
|||
product:
|
||||
brand: Elli
|
||||
description: Charger Connect (Beta)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
description: |
|
||||
Dem Gerät muss eine feste IP Adresse zugewiesen sein (Manuell oder per DHCP).
|
||||
|
||||
Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.
|
||||
|
||||
Wichtig: Die möglichst reibungslose Funktionalität ist aufgrund von Software-Fehlern in der Wallbox nur mit einem externen Energiezähler und ohne Stromwandlerspulen möglich! Eine LAN Anbindung wird sehr empfohlen.
|
||||
|
||||
Hinweis: Wenn du deiner Wallbox nachträglich einen Energiezähler hinzugefügt hast, nutze bitte die Pro bzw. Connected+ Integration.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: elliconnect
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse
|
||||
|
|
@ -1,20 +0,0 @@
|
|||
product:
|
||||
brand: Volkswagen
|
||||
description: ID. Charger Connect (Beta)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
description: |
|
||||
Dem Gerät muss eine feste IP Adresse zugewiesen sein (Manuell oder per DHCP).
|
||||
|
||||
Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.
|
||||
|
||||
Wichtig: Die möglichst reibungslose Funktionalität ist aufgrund von Software-Fehlern in der Wallbox nur mit einem externen Energiezähler und ohne Stromwandlerspulen möglich! Eine LAN Anbindung wird sehr empfohlen.
|
||||
|
||||
Hinweis: Wenn du deiner Wallbox nachträglich einen Energiezähler hinzugefügt hast, nutze bitte die Pro bzw. Connected+ Integration.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: elliconnect
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse
|
||||
|
|
@ -1,20 +0,0 @@
|
|||
product:
|
||||
brand: Skoda
|
||||
description: iV Charger Connect (Beta)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
description: |
|
||||
Dem Gerät muss eine feste IP Adresse zugewiesen sein (Manuell oder per DHCP).
|
||||
|
||||
Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.
|
||||
|
||||
Wichtig: Die möglichst reibungslose Funktionalität ist aufgrund von Software-Fehlern in der Wallbox nur mit einem externen Energiezähler und ohne Stromwandlerspulen möglich! Eine LAN Anbindung wird sehr empfohlen.
|
||||
|
||||
Hinweis: Wenn du deiner Wallbox nachträglich einen Energiezähler hinzugefügt hast, nutze bitte die Pro bzw. Connected+ Integration.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: elliconnect
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse
|
||||
|
|
@ -1,20 +0,0 @@
|
|||
product:
|
||||
brand: Cupra
|
||||
description: Charger Connect (Beta)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
description: |
|
||||
Dem Gerät muss eine feste IP Adresse zugewiesen sein (Manuell oder per DHCP).
|
||||
|
||||
Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.
|
||||
|
||||
Wichtig: Die möglichst reibungslose Funktionalität ist aufgrund von Software-Fehlern in der Wallbox nur mit einem externen Energiezähler und ohne Stromwandlerspulen möglich! Eine LAN Anbindung wird sehr empfohlen.
|
||||
|
||||
Hinweis: Wenn du deiner Wallbox nachträglich einen Energiezähler hinzugefügt hast, nutze bitte die Pro bzw. Connected+ Integration.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: elliconnect
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse
|
||||
|
|
@ -1,20 +0,0 @@
|
|||
product:
|
||||
brand: Audi
|
||||
description: Wallbox plus (Beta)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
description: |
|
||||
Dem Gerät muss eine feste IP Adresse zugewiesen sein (Manuell oder per DHCP).
|
||||
|
||||
Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.
|
||||
|
||||
Wichtig: Die möglichst reibungslose Funktionalität ist aufgrund von Software-Fehlern in der Wallbox nur mit einem externen Energiezähler und ohne Stromwandlerspulen möglich! Eine LAN Anbindung wird sehr empfohlen.
|
||||
|
||||
Hinweis: Wenn du deiner Wallbox nachträglich einen Energiezähler hinzugefügt hast, nutze bitte die Pro bzw. Connected+ Integration.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: elliconnect
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse
|
||||
|
|
@ -1,18 +0,0 @@
|
|||
product:
|
||||
brand: Elli
|
||||
description: Charger Pro (Beta)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
description: |
|
||||
Dem Gerät muss eine feste IP Adresse zugewiesen sein (Manuell oder per DHCP).
|
||||
|
||||
Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.
|
||||
|
||||
Wichtig: Die möglichst reibungslose Funktionalität ist aufgrund von Software-Fehlern in der Wallbox nur mit einem externen Energiezähler und ohne Stromwandlerspulen möglich! Eine LAN Anbindung wird sehr empfohlen.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: ellipro
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse
|
||||
|
|
@ -1,18 +0,0 @@
|
|||
product:
|
||||
brand: Volkswagen
|
||||
description: ID. Charger Pro (Beta)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
description: |
|
||||
Dem Gerät muss eine feste IP Adresse zugewiesen sein (Manuell oder per DHCP).
|
||||
|
||||
Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.
|
||||
|
||||
Wichtig: Die möglichst reibungslose Funktionalität ist aufgrund von Software-Fehlern in der Wallbox nur mit einem externen Energiezähler und ohne Stromwandlerspulen möglich! Eine LAN Anbindung wird sehr empfohlen.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: ellipro
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse
|
||||
|
|
@ -1,18 +0,0 @@
|
|||
product:
|
||||
brand: Skoda
|
||||
description: iV Charger Connect+ (Beta)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
description: |
|
||||
Dem Gerät muss eine feste IP Adresse zugewiesen sein (Manuell oder per DHCP).
|
||||
|
||||
Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.
|
||||
|
||||
Wichtig: Die möglichst reibungslose Funktionalität ist aufgrund von Software-Fehlern in der Wallbox nur mit einem externen Energiezähler und ohne Stromwandlerspulen möglich! Eine LAN Anbindung wird sehr empfohlen.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: ellipro
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse
|
||||
|
|
@ -1,18 +0,0 @@
|
|||
product:
|
||||
brand: Cupra
|
||||
description: Charger Pro (Beta)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
description: |
|
||||
Dem Gerät muss eine feste IP Adresse zugewiesen sein (Manuell oder per DHCP).
|
||||
|
||||
Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.
|
||||
|
||||
Wichtig: Die möglichst reibungslose Funktionalität ist aufgrund von Software-Fehlern in der Wallbox nur mit einem externen Energiezähler und ohne Stromwandlerspulen möglich! Eine LAN Anbindung wird sehr empfohlen.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: ellipro
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse
|
||||
|
|
@ -1,18 +0,0 @@
|
|||
product:
|
||||
brand: Audi
|
||||
description: Audi Wallbox pro (Beta)
|
||||
capabilities: ["mA"]
|
||||
requirements: ["eebus"]
|
||||
description: |
|
||||
Dem Gerät muss eine feste IP Adresse zugewiesen sein (Manuell oder per DHCP).
|
||||
|
||||
Eine Identifikation des Fahrzeugs über die RFID Karte ist nicht möglich.
|
||||
|
||||
Wichtig: Die möglichst reibungslose Funktionalität ist aufgrund von Software-Fehlern in der Wallbox nur mit einem externen Energiezähler und ohne Stromwandlerspulen möglich! Eine LAN Anbindung wird sehr empfohlen.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: ellipro
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse
|
||||
|
|
@ -1,18 +0,0 @@
|
|||
product:
|
||||
brand: EVBox
|
||||
description: Elvi
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: elvi
|
||||
meter: true # Deaktiveren wenn die Wallbox keinen integrierten Zähler verbaut hat (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: elvi
|
||||
stationid: EVB-P12354 # Die Stations-ID der Wallbox (oder des Ladepunkts). Diese ID muss auch Teil der Wallboxkonfiguration für OCPP sein ws://<evcc-address>:8887/<stationid>. (Optional)
|
||||
connector: 1 # Ladepunkt, normalerweise 1 für den ersten Anschluss. (Optional)
|
||||
idtag: '04E6B78921BBA0' # Token-ID welche für die Freischaltung der Ladevorgänge an den Ladepunkt zurückgesendet wird (Optional)
|
||||
connecttimeout: 5m # Optional
|
||||
timeout: 2m # Optional
|
||||
meter: true # Deaktiveren wenn die Wallbox keinen integrierten Zähler verbaut hat (Optional)
|
||||
meterinterval: 4s # Optional
|
||||
|
|
@ -1,16 +0,0 @@
|
|||
product:
|
||||
brand: EM2GO
|
||||
description: Pro Power/OCPP/ONC
|
||||
capabilities: ["mA"]
|
||||
description: |
|
||||
Aktuelle Firmware mit Modbus-Unterstützung notwendig (Pro Power: 1.01 bzw. OCPP/ONC: 3.15)
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: em2go
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 255
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,19 +0,0 @@
|
|||
product:
|
||||
brand: Etrel
|
||||
description: INCH Duo
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Die Wallbox muss sich im "Power" Modus befinden.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: etrel-duo
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: etrel-duo
|
||||
connector: 1 # Optional
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Etrel
|
||||
description: INCH
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Die Wallbox muss sich im "Power" Modus befinden.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: etrel
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Sonnen
|
||||
description: sonnenCharger
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Die Wallbox muss sich im "Power" Modus befinden.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: etrel
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,20 +0,0 @@
|
|||
product:
|
||||
brand: Stark in Strom
|
||||
description: Easy
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: evse-din
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,19 +0,0 @@
|
|||
product:
|
||||
description: EVSE DIN
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: evse-din
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,7 +0,0 @@
|
|||
product:
|
||||
description: EVSE-WiFi
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: evsewifi
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,23 +0,0 @@
|
|||
product:
|
||||
brand: AVM
|
||||
description: FritzDECT
|
||||
group: Schaltbare Steckdosen
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: fritzdect
|
||||
uri: https://fritz.box # HTTP(S) Adresse (Optional)
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
|
||||
ain: 307788992233 # Die AIN ist auf dem Typenschild auf der Geräterückseite aufgedruckt. Bei führenden Nullen bitte in doppelte Hochkommata setzen.
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: fritzdect
|
||||
uri: https://fritz.box # HTTP(S) Adresse (Optional)
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
|
||||
ain: 307788992233 # Die AIN ist auf dem Typenschild auf der Geräterückseite aufgedruckt. Bei führenden Nullen bitte in doppelte Hochkommata setzen.
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
integrateddevice: # Optional
|
||||
icon: # Icon in der Benutzeroberfläche (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Fronius
|
||||
description: Wattpilot
|
||||
capabilities: ["1p3p", "rfid"]
|
||||
description: |
|
||||
Benötigt mindestens Firmware 36.3 oder neuer.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: fronius-wattpilot
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional)
|
||||
|
|
@ -1,15 +0,0 @@
|
|||
product:
|
||||
brand: go-eCharger
|
||||
description: Gemini, HOME+, HOMEfix (V3)
|
||||
capabilities: ["1p3p", "rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Benötigt mindestens Firmware 052.1 oder neuer.
|
||||
|
||||
Für 1P/3P-Phasenumschaltung muss die HTTP API v2 im Charger aktiviert sein.
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: go-e-v3
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,12 +0,0 @@
|
|||
product:
|
||||
brand: go-eCharger
|
||||
description: HOME+, HOMEfix, Pro
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Benötigt mindestens Firmware 040.0 oder neuer. Das HTTP API v1 oder v2 muss aktiviert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: go-e
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,11 +0,0 @@
|
|||
product:
|
||||
brand: HardyBarth
|
||||
description: cPH1
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Als Betriebsmodus muss `manual` ausgewählt sein
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: hardybarth-ecb1
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,11 +0,0 @@
|
|||
product:
|
||||
brand: echarge
|
||||
description: cPH1
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Als Betriebsmodus muss `manual` ausgewählt sein
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: hardybarth-ecb1
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,9 +0,0 @@
|
|||
product:
|
||||
brand: HardyBarth
|
||||
description: cPH2, cPμ2
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: hardybarth-salia
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,9 +0,0 @@
|
|||
product:
|
||||
brand: echarge
|
||||
description: cPH2, cPμ2
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: hardybarth-salia
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,24 +0,0 @@
|
|||
product:
|
||||
brand: Heidelberg
|
||||
description: Energy Control
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Bitte das Handbuch zur Verkabelung und Konfiguration genau lesen. Alle Boxen müssen für die externe Steuerung auf Follower-Modus konfiguriert sein (DIP S5/4 OFF). Jede Box braucht eine individuelle Modbus-ID (DIP S4). Auf korrekte RS485-Verkabelung inkl. Busterminierung (DIP S6/2) achten.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: heidelberg
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8E1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,24 +0,0 @@
|
|||
product:
|
||||
brand: SENEC
|
||||
description: Wallbox pro s
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Bitte das Handbuch zur Verkabelung und Konfiguration genau lesen. Alle Boxen müssen für die externe Steuerung auf Follower-Modus konfiguriert sein (DIP S5/4 OFF). Jede Box braucht eine individuelle Modbus-ID (DIP S4). Auf korrekte RS485-Verkabelung inkl. Busterminierung (DIP S6/2) achten.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: heidelberg
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8E1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,24 +0,0 @@
|
|||
product:
|
||||
brand: Walther Werke
|
||||
description: Basic Evo Pro
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Bitte das Handbuch zur Verkabelung und Konfiguration genau lesen. Alle Boxen müssen für die externe Steuerung auf Follower-Modus konfiguriert sein (DIP S5/4 OFF). Jede Box braucht eine individuelle Modbus-ID (DIP S4). Auf korrekte RS485-Verkabelung inkl. Busterminierung (DIP S6/2) achten.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: heidelberg
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8E1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,24 +0,0 @@
|
|||
product:
|
||||
brand: Amperfied
|
||||
description: Wallbox Energy Control
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Bitte das Handbuch zur Verkabelung und Konfiguration genau lesen. Alle Boxen müssen für die externe Steuerung auf Follower-Modus konfiguriert sein (DIP S5/4 OFF). Jede Box braucht eine individuelle Modbus-ID (DIP S4). Auf korrekte RS485-Verkabelung inkl. Busterminierung (DIP S6/2) achten.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: heidelberg
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8E1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,14 +0,0 @@
|
|||
product:
|
||||
brand: Hesotec
|
||||
description: eSat, eBox
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: hesotec
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,27 +0,0 @@
|
|||
product:
|
||||
brand: Homematic / Homematic IP
|
||||
group: Schaltbare Steckdosen
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: homematic
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 2010 # Port (Optional)
|
||||
device: '0001EE89AAD848' # Homematic Geräte Id, wie im CCU Webfrontend angezeigt.
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.) (Optional)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional)
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: homematic
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 2010 # Port (Optional)
|
||||
device: '0001EE89AAD848' # Homematic Geräte Id, wie im CCU Webfrontend angezeigt.
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.) (Optional)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional)
|
||||
meterchannel: 6 # Kanalnummer des Messwertkanals, wie im CCU Webfrontend angezeigt.
|
||||
switchchannel: 3 # Kanalnummer der schaltbaren Steckdose, wie im CCU Webfrontend angezeigt.
|
||||
cache: 1s # Bei Problemen mit dem Duty Cycle setze den Cache auf bspw 30s. (Optional)
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
integrateddevice: # Optional
|
||||
icon: # Icon in der Benutzeroberfläche (Optional)
|
||||
|
|
@ -1,16 +0,0 @@
|
|||
product:
|
||||
brand: HomeWizard
|
||||
group: Schaltbare Steckdosen
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: homewizard
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: homewizard
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
integrateddevice: # Optional
|
||||
icon: # Icon in der Benutzeroberfläche (Optional)
|
||||
|
|
@ -1,13 +0,0 @@
|
|||
product:
|
||||
brand: Schrack
|
||||
description: i-CHARGE CION
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: ichargecion
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,15 +0,0 @@
|
|||
product:
|
||||
brand: Innogy
|
||||
description: eBox
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: innogy-ebox
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,15 +0,0 @@
|
|||
product:
|
||||
brand: E.ON Drive
|
||||
description: eBox
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: innogy-ebox
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,15 +0,0 @@
|
|||
product:
|
||||
brand: Compleo
|
||||
description: eBox
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: innogy-ebox
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,17 +0,0 @@
|
|||
product:
|
||||
brand: KEBA
|
||||
description: KeContact P20, P30, C/X Series
|
||||
capabilities: ["1p3p", "mA", "rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Erfordert Firmwareversion 3.10.42 (C-series) bzw. 1.11 (X-series). Zur Phasenumschaltung wird zusätzlich der Keba Phasenumschalter (KeContact S10) benötigt.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: keba-modbus
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 255
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,17 +0,0 @@
|
|||
product:
|
||||
brand: BMW
|
||||
description: i Wallbox
|
||||
capabilities: ["1p3p", "mA", "rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Erfordert Firmwareversion 3.10.42 (C-series) bzw. 1.11 (X-series). Zur Phasenumschaltung wird zusätzlich der Keba Phasenumschalter (KeContact S10) benötigt.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: keba-modbus
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 255
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,17 +0,0 @@
|
|||
product:
|
||||
brand: SolarEdge
|
||||
description: Home EV Charger
|
||||
capabilities: ["1p3p", "mA", "rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Erfordert Firmwareversion 3.10.42 (C-series) bzw. 1.11 (X-series). Zur Phasenumschaltung wird zusätzlich der Keba Phasenumschalter (KeContact S10) benötigt.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: keba-modbus
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 255
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,17 +0,0 @@
|
|||
product:
|
||||
brand: KEBA
|
||||
description: KeContact P20, P30, C/X Series (legacy UDP protocol)
|
||||
capabilities: ["mA", "rfid"]
|
||||
description: |
|
||||
Es muss eine sogenannte UDP Funktion über den DIP Schalter 1.3 eingeschaltet (ON) werden. Die Installationsanleitung der Wallbox hilft hier weiter.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: keba
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
advanced: |
|
||||
type: template
|
||||
template: keba
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
rfid: 765765348 # Die Kennung eines RFID-Tags um den Lademodus zu starten, selbst wenn die Wallbox gesperrt ist. (Optional)
|
||||
serial: # Die Seriennummer, ermöglicht es auch mit der Wallbox zu kommunizieren wenn evcc in Docker läuft. (Optional)
|
||||
|
|
@ -1,17 +0,0 @@
|
|||
product:
|
||||
brand: BMW
|
||||
description: i Wallbox (legacy UDP protocol)
|
||||
capabilities: ["mA", "rfid"]
|
||||
description: |
|
||||
Es muss eine sogenannte UDP Funktion über den DIP Schalter 1.3 eingeschaltet (ON) werden. Die Installationsanleitung der Wallbox hilft hier weiter.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: keba
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
advanced: |
|
||||
type: template
|
||||
template: keba
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
rfid: 765765348 # Die Kennung eines RFID-Tags um den Lademodus zu starten, selbst wenn die Wallbox gesperrt ist. (Optional)
|
||||
serial: # Die Seriennummer, ermöglicht es auch mit der Wallbox zu kommunizieren wenn evcc in Docker läuft. (Optional)
|
||||
|
|
@ -1,22 +0,0 @@
|
|||
product:
|
||||
brand: KSE
|
||||
description: wBX16
|
||||
capabilities: ["rfid"]
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: kse
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 100
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8E1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 100
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,17 +0,0 @@
|
|||
product:
|
||||
brand: myStrom
|
||||
description: Switch
|
||||
group: Schaltbare Steckdosen
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: mystrom
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: mystrom
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
integrateddevice: # Optional
|
||||
icon: # Icon in der Benutzeroberfläche (Optional)
|
||||
|
|
@ -1,9 +0,0 @@
|
|||
product:
|
||||
brand: NRGKick
|
||||
description: Bluetooth
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: nrgkick-bluetooth
|
||||
mac:
|
||||
pin:
|
||||
|
|
@ -1,10 +0,0 @@
|
|||
product:
|
||||
brand: NRGKick
|
||||
description: Connect
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: nrgkick-connect
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
mac:
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
|
||||
|
|
@ -1,26 +0,0 @@
|
|||
product:
|
||||
brand: OBO Bettermann
|
||||
description: Ion
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: obo
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 101
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8E1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 101
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 101
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,35 +0,0 @@
|
|||
product:
|
||||
description: OCPP 1.6J kompatible Wallbox mit Smart Charging Profil
|
||||
group: Generische Unterstützung
|
||||
description: |
|
||||
Bei OCPP verbindet sich die Wallbox (Client) zu evcc (Server).
|
||||
Die Wallbox muss daher evcc via Hostname (funktionierende DNS-Auflösung erforderlich!) oder über die IP-Adresse auf Port 8887 erreichen können.
|
||||
Standardmäßig wird die erste eingehende Verbindung mit einer beliebigen Ladepunktkennung verwendet.
|
||||
Um mehrere Ladepunkte eindeutig zuordnen zu können müssen die jeweilige Stationskennung (`stationid: `) und Anschlussnummer (`connector: `) hinterlegt werden.
|
||||
Viele Wallboxen fügen die `stationid` automatisch der Backend-URL hinzu, bei manchen muss dies händisch geschehen `ws://<evcc>:8887/<stationid>`.
|
||||
Gegebenenfalls benötigt der Ladepunkt eine vorkonfigurierte (virtuelle) Token-ID/RFID-Kennung (`idtag: `) mit der die Ladevorgänge ohne Authentifizierung gestartet werden können.
|
||||
Für Zählermesswerte sollte in der Wallbox ein kurzes Zeitintervall konfiguriert werden.
|
||||
|
||||
Voraussetzungen:
|
||||
* Ggf. zuvor konfigurierte OCPP-Profile (z.B. durch eine andere Backend-Anbindung) in der Wallboxkonfiguration entfernen
|
||||
* Backend-URL (Central System) in der Wallboxkonfiguration: `ws://[evcc-adresse]:8887/` (evtl noch um `stationid` erweitern)
|
||||
* Protokoll: OCPP-J v1.6, ocpp16j, JSON, Websocket, ws:// o.ä.
|
||||
* Keine Verschlüsselung, keine Authentifizierung, kein Passwort
|
||||
* Verbindung über das lokale Netzwerk
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: ocpp
|
||||
advanced: |
|
||||
type: template
|
||||
template: ocpp
|
||||
stationid: EVB-P12354 # Die Stations-ID der Wallbox (oder des Ladepunkts). Diese ID muss auch Teil der Wallboxkonfiguration für OCPP sein ws://<evcc-address>:8887/<stationid>. (Optional)
|
||||
connector: 1 # Ladepunkt, normalerweise 1 für den ersten Anschluss. (Optional)
|
||||
idtag: '04E6B78921BBA0' # Token-ID welche für die Freischaltung der Ladevorgänge an den Ladepunkt zurückgesendet wird (Optional)
|
||||
connecttimeout: 5m # Optional
|
||||
timeout: 2m # Optional
|
||||
getconfiguration: true # Deaktivierung kann bei einigen Chargern hilfreich sein (Optional)
|
||||
bootnotification: false # Aktivierung kann bei einigen Chargern hilfreich sein (Optional)
|
||||
meterinterval: # Optional
|
||||
metervalues: # Optional
|
||||
|
|
@ -1,11 +0,0 @@
|
|||
product:
|
||||
brand: OpenEVSE
|
||||
description: |
|
||||
Benötigt mindestens Firmware 7.0 oder neuer.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: openevse
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.) (Optional)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional)
|
||||
|
|
@ -1,9 +0,0 @@
|
|||
product:
|
||||
brand: openWB
|
||||
description: Pro
|
||||
capabilities: ["1p3p", "mA", "iso151182"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: openwb-pro
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,16 +0,0 @@
|
|||
product:
|
||||
brand: openWB
|
||||
description: series2
|
||||
description: |
|
||||
Die Wallbox muss als Ladepunkt konfiguriert sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: openwb
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
advanced: |
|
||||
type: template
|
||||
template: openwb
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
connector: 1 # Optional
|
||||
phases1p3p: false # Optional
|
||||
|
|
@ -1,15 +0,0 @@
|
|||
product:
|
||||
brand: Orbis
|
||||
description: Viaris Uni
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: orbis-viaris
|
||||
advanced: |
|
||||
type: template
|
||||
template: orbis-viaris
|
||||
stationid: EVB-P12354 # Die Stations-ID der Wallbox (oder des Ladepunkts). Diese ID muss auch Teil der Wallboxkonfiguration für OCPP sein ws://<evcc-address>:8887/<stationid>. (Optional)
|
||||
connector: 1 # Ladepunkt, normalerweise 1 für den ersten Anschluss. (Optional)
|
||||
idtag: '04E6B78921BBA0' # Token-ID welche für die Freischaltung der Ladevorgänge an den Ladepunkt zurückgesendet wird (Optional)
|
||||
connecttimeout: 5m # Optional
|
||||
timeout: 2m # Optional
|
||||
|
|
@ -1,8 +0,0 @@
|
|||
product:
|
||||
brand: INRO
|
||||
description: Pantabox
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: pantabox
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,12 +0,0 @@
|
|||
product:
|
||||
brand: PC Electric
|
||||
description: Garo
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Es können momentan nur als Master konfigurierte Geräte verwendet werden!
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: pcelectric-garo
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 8080 # Port (Optional)
|
||||
|
|
@ -1,15 +0,0 @@
|
|||
product:
|
||||
brand: Phoenix
|
||||
description: CHARX
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: phoenix-charx
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: phoenix-charx
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
connector: 1 # Optional
|
||||
|
|
@ -1,15 +0,0 @@
|
|||
product:
|
||||
brand: LadeFoxx
|
||||
description: EvLoad/ Mikro 2.0
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: phoenix-charx
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: phoenix-charx
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
connector: 1 # Optional
|
||||
|
|
@ -1,11 +0,0 @@
|
|||
product:
|
||||
brand: Phoenix
|
||||
description: EM-CP-PP-ETH (Modbus TCP)
|
||||
description: |
|
||||
Die Wallbox muss über ein Netzwerkkabel angebunden sein und im Gerät muss der DIP Schalter 10 auf 'ON' gestellt sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: phoenix-em-eth
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,11 +0,0 @@
|
|||
product:
|
||||
brand: Phoenix
|
||||
description: EV-ETH (Modbus TCP)
|
||||
description: |
|
||||
Die Wallbox muss über ein Netzwerkkabel angebunden sein und im Gerät muss der DIP Schalter 10 auf 'ON' gestellt sein.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: phoenix-ev-eth
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port (Optional)
|
||||
|
|
@ -1,20 +0,0 @@
|
|||
product:
|
||||
brand: Phoenix
|
||||
description: EV-SER (Modbus RTU)
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: phoenix-ev-ser
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,11 +0,0 @@
|
|||
product:
|
||||
brand: Porsche
|
||||
description: Mobile Charger Connect
|
||||
capabilities: ["iso151182", "mA"]
|
||||
requirements: ["eebus"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: pmcc
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse (Optional)
|
||||
|
|
@ -1,10 +0,0 @@
|
|||
product:
|
||||
brand: Porsche
|
||||
description: Mobile Charger Plus
|
||||
requirements: ["eebus"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: pmcp
|
||||
ski: # Die SKI der Wallbox, üblicherweise im Web Interface der Wallbox zu finden
|
||||
ip: 192.0.2.2 # IP-Adresse (Optional)
|
||||
|
|
@ -1,51 +0,0 @@
|
|||
product:
|
||||
brand: Pracht
|
||||
description: Alpha XT, XT+, Mono XT, Mono XT+, PNI
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: pracht-alpha
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
advanced: |
|
||||
type: template
|
||||
template: pracht-alpha
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
connector: 1 # Optional
|
||||
timeout: 10s # Optional
|
||||
|
|
@ -1,22 +0,0 @@
|
|||
product:
|
||||
brand: wallbox
|
||||
description: Pulsar Plus / Commander 2 / Copper SB
|
||||
description: |
|
||||
Anleitung: https://support.wallbox.com/en/knowledge-base/ocpp-activation-and-setup-guide/
|
||||
* “OCPP aktivieren” (myWallbox app) bzw. den “OCPP-WebSocket-Verbindung” Schalter (myWallbox Portal) aktivieren
|
||||
* URL: ws://[evcc-adresse]:8887/ (Verbindung über das lokale Netzwerk)
|
||||
* Ladepunktidentität: beliebiger Wert (z.B. die Seriennummer der Box), der als *stationid* verwendet wird
|
||||
* Passwort: leer lassen
|
||||
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: pulsarplus
|
||||
advanced: |
|
||||
type: template
|
||||
template: pulsarplus
|
||||
stationid: EVB-P12354 # Die Stations-ID der Wallbox (oder des Ladepunkts). Diese ID muss auch Teil der Wallboxkonfiguration für OCPP sein ws://<evcc-address>:8887/<stationid>. (Optional)
|
||||
connector: 1 # Ladepunkt, normalerweise 1 für den ersten Anschluss. (Optional)
|
||||
idtag: '04E6B78921BBA0' # Token-ID welche für die Freischaltung der Ladevorgänge an den Ladepunkt zurückgesendet wird (Optional)
|
||||
connecttimeout: 5m # Optional
|
||||
timeout: 2m # Optional
|
||||
|
|
@ -1,14 +0,0 @@
|
|||
product:
|
||||
brand: Schneider
|
||||
description: EVlink Wallbox, EVlink Parkplatz
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: schneider-evlink
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 255
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,22 +0,0 @@
|
|||
product:
|
||||
brand: Shelly
|
||||
group: Schaltbare Steckdosen
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: shelly
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.) (Optional)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional)
|
||||
channel: 0 # Optional
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: shelly
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.) (Optional)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional)
|
||||
channel: 0 # Optional
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
integrateddevice: # Optional
|
||||
icon: # Icon in der Benutzeroberfläche (Optional)
|
||||
|
|
@ -1,14 +0,0 @@
|
|||
product:
|
||||
brand: SMA
|
||||
description: EV Charger
|
||||
capabilities: ["mA"]
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Der EV Charger muss sich im Modus "Fast" befinden und der Benutzer muss die Rechte "Administrator" haben.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: smaevcharger
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
|
||||
|
|
@ -1,7 +0,0 @@
|
|||
product:
|
||||
description: smartWB
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: smartwb
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,21 +0,0 @@
|
|||
product:
|
||||
brand: TP-Link
|
||||
description: Tapo P-Series Smart Plug
|
||||
group: Schaltbare Steckdosen
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: tapo
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: tapo
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
integrateddevice: # Optional
|
||||
icon: # Icon in der Benutzeroberfläche (Optional)
|
||||
|
|
@ -1,22 +0,0 @@
|
|||
product:
|
||||
brand: Tasmota
|
||||
group: Schaltbare Steckdosen
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: tasmota
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
user: # Standard-User ist admin (Optional)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional)
|
||||
channel: 1 # Nummer des Schaltkanals (1-8), bei Geräten mit mehr als einem Schalter
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: tasmota
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
user: # Standard-User ist admin (Optional)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional)
|
||||
channel: 1 # Nummer des Schaltkanals (1-8), bei Geräten mit mehr als einem Schalter
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
integrateddevice: # Optional
|
||||
icon: # Icon in der Benutzeroberfläche (Optional)
|
||||
|
|
@ -1,24 +0,0 @@
|
|||
product:
|
||||
brand: TinkerForge
|
||||
description: WARP Charger Smart
|
||||
capabilities: ["mA", "1p3p"]
|
||||
description: |
|
||||
Firmware v2 erforderlich. Für automatische Phasenumschaltung wird zusätzlich der WARP Energy Manager benötigt.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: tinkerforge-warp
|
||||
host: 192.0.2.2 # IP Adresse oder der Hostname des MQTT Brokers
|
||||
port: 1883 # MQTT Broker Port (Optional)
|
||||
topic: warp # Topic (ohne / am Anfang) (Optional)
|
||||
energymanager: # EnergyManager MQTT Topic (falls installiert) (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: tinkerforge-warp
|
||||
host: 192.0.2.2 # IP Adresse oder der Hostname des MQTT Brokers
|
||||
port: 1883 # MQTT Broker Port (Optional)
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.) (Optional)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional)
|
||||
topic: warp # Topic (ohne / am Anfang) (Optional)
|
||||
timeout: 30s # Akzeptiere keine Daten die älter sind als dieser Wert (Optional)
|
||||
energymanager: # EnergyManager MQTT Topic (falls installiert) (Optional)
|
||||
|
|
@ -1,24 +0,0 @@
|
|||
product:
|
||||
brand: TinkerForge
|
||||
description: WARP Charger Pro
|
||||
capabilities: ["mA", "1p3p"]
|
||||
description: |
|
||||
Firmware v2 erforderlich. Für automatische Phasenumschaltung wird zusätzlich der WARP Energy Manager benötigt.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: tinkerforge-warp
|
||||
host: 192.0.2.2 # IP Adresse oder der Hostname des MQTT Brokers
|
||||
port: 1883 # MQTT Broker Port (Optional)
|
||||
topic: warp # Topic (ohne / am Anfang) (Optional)
|
||||
energymanager: # EnergyManager MQTT Topic (falls installiert) (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: tinkerforge-warp
|
||||
host: 192.0.2.2 # IP Adresse oder der Hostname des MQTT Brokers
|
||||
port: 1883 # MQTT Broker Port (Optional)
|
||||
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.) (Optional)
|
||||
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) (Optional)
|
||||
topic: warp # Topic (ohne / am Anfang) (Optional)
|
||||
timeout: 30s # Akzeptiere keine Daten die älter sind als dieser Wert (Optional)
|
||||
energymanager: # EnergyManager MQTT Topic (falls installiert) (Optional)
|
||||
|
|
@ -1,17 +0,0 @@
|
|||
product:
|
||||
brand: TP-Link
|
||||
description: H-Series Smart Plug
|
||||
group: Schaltbare Steckdosen
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: tplink
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
advanced: |
|
||||
type: template
|
||||
template: tplink
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
standbypower: 15 # Leistung oberhalb des angegebenen Wertes wird als Ladeleistung gewertet (Optional)
|
||||
integrateddevice: # Optional
|
||||
icon: # Icon in der Benutzeroberfläche (Optional)
|
||||
|
|
@ -1,10 +0,0 @@
|
|||
product:
|
||||
brand: Tesla
|
||||
description: TWC3
|
||||
description: |
|
||||
Die TWC Wallbox ist nicht direkt regelbar. Die Regelung erfolgt über das Fahrzeug. Das Fahrzeug muss dem TWC3 Ladepunkt zugewiesen sein. Aktuell ausschließlich mit Tesla Fahrzeugen nutzbar.
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: twc3
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
|
|
@ -1,16 +0,0 @@
|
|||
product:
|
||||
brand: Siemens
|
||||
description: Versicharge GEN3
|
||||
requirements: ["sponsorship"]
|
||||
description: |
|
||||
Erfordert Firmware >= 2.121.5
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: versicharge
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 2
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,14 +0,0 @@
|
|||
product:
|
||||
brand: Vestel
|
||||
description: EVC04 Home Smart/Connect Plus
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: vestel
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 255
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,14 +0,0 @@
|
|||
product:
|
||||
brand: Webasto
|
||||
description: Unite
|
||||
requirements: ["sponsorship"]
|
||||
render:
|
||||
- default: |
|
||||
type: template
|
||||
template: vestel
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 255
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
Some files were not shown because too many files have changed in this diff Show more
Loading…
Add table
Add a link
Reference in a new issue