Add M-TEC Energy Butler (#8901)
This commit is contained in:
parent
fd327c3fb3
commit
383ef6a044
5 changed files with 212 additions and 0 deletions
47
templates/definition/meter/mtec-eb-gen2.yaml
Normal file
47
templates/definition/meter/mtec-eb-gen2.yaml
Normal file
|
|
@ -0,0 +1,47 @@
|
|||
template: mtec-eb-gen2
|
||||
products:
|
||||
- brand: M-TEC
|
||||
description:
|
||||
generic: Energy Butler GEN2
|
||||
params:
|
||||
- name: usage
|
||||
choice: ["grid", "pv", "battery"]
|
||||
- name: modbus
|
||||
choice: ["rs485"]
|
||||
render: |
|
||||
type: custom
|
||||
{{- if eq .usage "grid" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 11000 # Zähler (NVP) Leistung
|
||||
type: holding
|
||||
decode: int32
|
||||
{{- end }}
|
||||
{{- if eq .usage "pv" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 11028 # PV Leistung
|
||||
type: holding
|
||||
decode: uint32
|
||||
{{- end }}
|
||||
{{- if eq .usage "battery" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 40258 # Batterie Leistung
|
||||
type: holding
|
||||
decode: int32
|
||||
soc:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 43000 # State of Charge (SOC)
|
||||
type: holding
|
||||
decode: uint16
|
||||
scale: 0.01
|
||||
{{- end }}
|
||||
47
templates/definition/meter/mtec-eb-gen3.yaml
Normal file
47
templates/definition/meter/mtec-eb-gen3.yaml
Normal file
|
|
@ -0,0 +1,47 @@
|
|||
template: mtec-eb-gen3
|
||||
products:
|
||||
- brand: M-TEC
|
||||
description:
|
||||
generic: Energy Butler GEN3
|
||||
params:
|
||||
- name: usage
|
||||
choice: ["grid", "pv", "battery"]
|
||||
- name: modbus
|
||||
choice: ["rs485"]
|
||||
render: |
|
||||
type: custom
|
||||
{{- if eq .usage "grid" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 11000 # Zähler (NVP) Leistung
|
||||
type: holding
|
||||
decode: int32
|
||||
{{- end }}
|
||||
{{- if eq .usage "pv" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 11028 # PV Leistung
|
||||
type: holding
|
||||
decode: uint32
|
||||
{{- end }}
|
||||
{{- if eq .usage "battery" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 30258 # Batterie Leistung
|
||||
type: holding
|
||||
decode: int32
|
||||
soc:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 33000 # State of Charge (SOC)
|
||||
type: holding
|
||||
decode: uint16
|
||||
scale: 0.01
|
||||
{{- end }}
|
||||
58
templates/docs/meter/mtec-eb-gen2_0.yaml
Normal file
58
templates/docs/meter/mtec-eb-gen2_0.yaml
Normal file
|
|
@ -0,0 +1,58 @@
|
|||
product:
|
||||
brand: M-TEC
|
||||
description: Energy Butler GEN2
|
||||
render:
|
||||
- usage: grid
|
||||
default: |
|
||||
type: template
|
||||
template: mtec-eb-gen2
|
||||
usage: grid
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
- usage: pv
|
||||
default: |
|
||||
type: template
|
||||
template: mtec-eb-gen2
|
||||
usage: pv
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
- usage: battery
|
||||
default: |
|
||||
type: template
|
||||
template: mtec-eb-gen2
|
||||
usage: battery
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
58
templates/docs/meter/mtec-eb-gen3_0.yaml
Normal file
58
templates/docs/meter/mtec-eb-gen3_0.yaml
Normal file
|
|
@ -0,0 +1,58 @@
|
|||
product:
|
||||
brand: M-TEC
|
||||
description: Energy Butler GEN3
|
||||
render:
|
||||
- usage: grid
|
||||
default: |
|
||||
type: template
|
||||
template: mtec-eb-gen3
|
||||
usage: grid
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
- usage: pv
|
||||
default: |
|
||||
type: template
|
||||
template: mtec-eb-gen3
|
||||
usage: pv
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
- usage: battery
|
||||
default: |
|
||||
type: template
|
||||
template: mtec-eb-gen3
|
||||
usage: battery
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -97,6 +97,7 @@
|
|||
"Janitza",
|
||||
"Kostal",
|
||||
"LG",
|
||||
"M-TEC",
|
||||
"my-PV",
|
||||
"myStrom",
|
||||
"OpenEMS",
|
||||
|
|
@ -147,6 +148,7 @@
|
|||
"IGEN Tech",
|
||||
"Kostal",
|
||||
"LG",
|
||||
"M-TEC",
|
||||
"myStrom",
|
||||
"OpenEMS",
|
||||
"Powerfox",
|
||||
|
|
|
|||