Offset available power by dc-generated battery charge (#2735)
This commit is contained in:
parent
c6fdbc07c3
commit
38defb679e
1 changed files with 7 additions and 5 deletions
|
|
@ -23,13 +23,15 @@ func powerToCurrent(power float64, phases int) float64 {
|
|||
return power / (float64(phases) * Voltage)
|
||||
}
|
||||
|
||||
// consumedPower estimates how much power the charger might have consumed given it was the only load
|
||||
// func consumedPower(pv, battery, grid float64) float64 {
|
||||
// return math.Abs(pv) + battery + grid
|
||||
// }
|
||||
|
||||
// sitePower returns the available delta power that the charger might additionally consume
|
||||
// negative value: available power (grid export), positive value: grid import
|
||||
func sitePower(grid, battery, residual float64) float64 {
|
||||
// For hybrid inverters, battery can be charged from DC power in excess of
|
||||
// inverter AC rating. This must be offset by the grid consumption when calculating
|
||||
// available site power.
|
||||
// (https://github.com/evcc-io/evcc/issues/2734)
|
||||
if grid > 0 && battery < 0 && grid-battery > 50 {
|
||||
battery = 0
|
||||
}
|
||||
return grid + battery + residual
|
||||
}
|
||||
|
|
|
|||