Victron Energy: add param for grid-meter VRM instance (#15625)
This commit is contained in:
parent
88daef4170
commit
3a4917536a
1 changed files with 9 additions and 3 deletions
|
|
@ -13,6 +13,12 @@ params:
|
|||
default: 502
|
||||
- name: capacity
|
||||
advanced: true
|
||||
- name: meterid # grid meter VRM instance
|
||||
usages: ["grid"]
|
||||
default: 30
|
||||
help:
|
||||
de: "Grid-Energiezähler VRM instance- kann im VRM Portal oder im RemoteUI ausgelesen werden."
|
||||
en: "Grid-Meter VRM instance- can be read out in VRM portal or via remoteUI."
|
||||
# battery control
|
||||
- name: minsoc
|
||||
type: number
|
||||
|
|
@ -50,7 +56,7 @@ render: |
|
|||
currents:
|
||||
- source: modbus
|
||||
uri: {{ .host }}:{{ .port }}
|
||||
id: 30
|
||||
id: {{ .meterid }}
|
||||
register:
|
||||
address: 2617 # L1 grid current
|
||||
type: input
|
||||
|
|
@ -58,7 +64,7 @@ render: |
|
|||
scale: 0.1
|
||||
- source: modbus
|
||||
uri: {{ .host }}:{{ .port }}
|
||||
id: 30
|
||||
id: {{ .meterid }}
|
||||
register:
|
||||
address: 2619 # L2 grid current
|
||||
type: input
|
||||
|
|
@ -66,7 +72,7 @@ render: |
|
|||
scale: 0.1
|
||||
- source: modbus
|
||||
uri: {{ .host }}:{{ .port }}
|
||||
id: 30
|
||||
id: {{ .meterid }}
|
||||
register:
|
||||
address: 2621 # L3 grid current
|
||||
type: input
|
||||
|
|
|
|||