Sungrow: remove dongle template (#3112)

This commit is contained in:
premultiply 2022-04-11 20:57:10 +02:00 • committed by andig
parent 552b50981a
commit 4bfa2b8a8e
4 changed files with 5 additions and 154 deletions

View file

@ -1,72 +0,0 @@
template: sungrow-dongle
products:
- brand: Sungrow
description:
generic: Inverter (Wifi dongle)
guidedsetup:
enable: true
requirements:
description:
generic: beta
params:
- name: usage
choice: ["grid", "pv", "battery"]
- name: modbus
choice: ["rs485", "tcpip"]
render: |
type: custom
{{- if eq .usage "grid" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
type: input
address: 13009 # Export power
decode: int32s
scale: -1
{{- end }}
{{- if eq .usage "pv" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
type: input
address: 5016 # Total DC power
decode: uint32s
{{- end }}
{{- if eq .usage "battery" }}
power:
source: calc
mul:
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
type: holding
address: 13022 # Battery power
decode: int16
- source: calc
add:
- source: modbus
{{- include "modbus" . | indent 6 }}
register:
type: holding
address: 13001 # Battery running state
decode: bool16
bitmask: 2 # Charging
scale: -1
- source: modbus
{{- include "modbus" . | indent 6 }}
register:
type: holding
address: 13001 # Battery running state
decode: bool16
bitmask: 4 # Discharging
soc:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 13022 # Battery level
type: input
decode: int16
scale: 0.1
{{- end }}

View file

@ -2,12 +2,13 @@ template: sungrow
products:
- brand: Sungrow
description:
generic: Inverter (LAN)
generic: Inverter
guidedsetup:
enable: true
requirements:
description:
generic: beta
de: Die Verbindung zu Sungrow-Geräten ist nur über den LAN-Port (am Gerät) oder seriell via RS485-Port möglich. Nicht verfügbar über das WiNet-S-Dongle!
en: Communication to Sungrow-Devices may only be established by using the LAN port (on device) or serial RS485 port. Not available on WiNet-S-Dongle!
params:
- name: usage
choice: ["grid", "pv", "battery"]

View file

@ -1,78 +0,0 @@
product:
brand: Sungrow
description: Inverter (Wifi dongle)
description: |
beta
render:
- usage: grid
default: |
type: template
template: sungrow-dongle
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: pv
default: |
type: template
template: sungrow-dongle
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: battery
default: |
type: template
template: sungrow-dongle
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port

View file

@ -1,8 +1,8 @@
product:
brand: Sungrow
description: Inverter (LAN)
description: Inverter
description: |
beta
Die Verbindung zu Sungrow-Geräten ist nur über den LAN-Port (am Gerät) oder seriell via RS485-Port möglich. Nicht verfügbar über das WiNet-S-Dongle!
render:
- usage: grid
default: |