Sungrow: remove dongle template (#3112)
This commit is contained in:
parent
552b50981a
commit
4bfa2b8a8e
4 changed files with 5 additions and 154 deletions
|
|
@ -1,72 +0,0 @@
|
|||
template: sungrow-dongle
|
||||
products:
|
||||
- brand: Sungrow
|
||||
description:
|
||||
generic: Inverter (Wifi dongle)
|
||||
guidedsetup:
|
||||
enable: true
|
||||
requirements:
|
||||
description:
|
||||
generic: beta
|
||||
params:
|
||||
- name: usage
|
||||
choice: ["grid", "pv", "battery"]
|
||||
- name: modbus
|
||||
choice: ["rs485", "tcpip"]
|
||||
render: |
|
||||
type: custom
|
||||
{{- if eq .usage "grid" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
type: input
|
||||
address: 13009 # Export power
|
||||
decode: int32s
|
||||
scale: -1
|
||||
{{- end }}
|
||||
{{- if eq .usage "pv" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
type: input
|
||||
address: 5016 # Total DC power
|
||||
decode: uint32s
|
||||
{{- end }}
|
||||
{{- if eq .usage "battery" }}
|
||||
power:
|
||||
source: calc
|
||||
mul:
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 4 }}
|
||||
register:
|
||||
type: holding
|
||||
address: 13022 # Battery power
|
||||
decode: int16
|
||||
- source: calc
|
||||
add:
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 6 }}
|
||||
register:
|
||||
type: holding
|
||||
address: 13001 # Battery running state
|
||||
decode: bool16
|
||||
bitmask: 2 # Charging
|
||||
scale: -1
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 6 }}
|
||||
register:
|
||||
type: holding
|
||||
address: 13001 # Battery running state
|
||||
decode: bool16
|
||||
bitmask: 4 # Discharging
|
||||
soc:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 13022 # Battery level
|
||||
type: input
|
||||
decode: int16
|
||||
scale: 0.1
|
||||
{{- end }}
|
||||
|
|
@ -2,12 +2,13 @@ template: sungrow
|
|||
products:
|
||||
- brand: Sungrow
|
||||
description:
|
||||
generic: Inverter (LAN)
|
||||
generic: Inverter
|
||||
guidedsetup:
|
||||
enable: true
|
||||
requirements:
|
||||
description:
|
||||
generic: beta
|
||||
de: Die Verbindung zu Sungrow-Geräten ist nur über den LAN-Port (am Gerät) oder seriell via RS485-Port möglich. Nicht verfügbar über das WiNet-S-Dongle!
|
||||
en: Communication to Sungrow-Devices may only be established by using the LAN port (on device) or serial RS485 port. Not available on WiNet-S-Dongle!
|
||||
params:
|
||||
- name: usage
|
||||
choice: ["grid", "pv", "battery"]
|
||||
|
|
|
|||
|
|
@ -1,78 +0,0 @@
|
|||
product:
|
||||
brand: Sungrow
|
||||
description: Inverter (Wifi dongle)
|
||||
description: |
|
||||
beta
|
||||
render:
|
||||
- usage: grid
|
||||
default: |
|
||||
type: template
|
||||
template: sungrow-dongle
|
||||
usage: grid
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
- usage: pv
|
||||
default: |
|
||||
type: template
|
||||
template: sungrow-dongle
|
||||
usage: pv
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
- usage: battery
|
||||
default: |
|
||||
type: template
|
||||
template: sungrow-dongle
|
||||
usage: battery
|
||||
|
||||
# RS485 via adapter (Modbus RTU)
|
||||
modbus: rs485serial
|
||||
id: 1
|
||||
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
|
||||
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
|
||||
comset: "8N1" # Kommunikationsparameter für den Adapter
|
||||
|
||||
# RS485 via TCP/IP (Modbus RTU)
|
||||
modbus: rs485tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
||||
# Modbus TCP
|
||||
modbus: tcpip
|
||||
id: 1
|
||||
host: 192.0.2.2 # Hostname
|
||||
port: 502 # Port
|
||||
|
|
@ -1,8 +1,8 @@
|
|||
product:
|
||||
brand: Sungrow
|
||||
description: Inverter (LAN)
|
||||
description: Inverter
|
||||
description: |
|
||||
beta
|
||||
Die Verbindung zu Sungrow-Geräten ist nur über den LAN-Port (am Gerät) oder seriell via RS485-Port möglich. Nicht verfügbar über das WiNet-S-Dongle!
|
||||
render:
|
||||
- usage: grid
|
||||
default: |
|
||||
|
|
|
|||