Add Anker SOLIX X1 (#29548)

This commit is contained in:
premultiply 2026-05-02 06:08:35 +02:00 • committed by GitHub
parent 93681522ab
commit 4e6716c508
No known key found for this signature in database
GPG key ID: B5690EEEBB952194

View file

@ -0,0 +1,145 @@
template: anker-solix-x1
products:
- brand: Anker
description:
generic: SOLIX X1 Hybrid Inverter
requirements:
description:
de: |
Die Modbus-TCP-Schnittstelle muss in der Anker-App freigeschaltet werden.
en: |
The Modbus TCP interface must be enabled in the Anker app.
params:
- name: usage
choice: ["grid", "pv", "battery"]
- name: modbus
choice: ["tcpip"]
port: 502
id: 1
- name: maxacpower
- preset: battery-params
render: |
type: custom
{{- if eq .usage "grid" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 10644 # Meter Total Active Power (W, positive = import, negative = export)
type: input
decode: int32
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 10656 # Meter Total Forward Active Energy (kWh)
type: input
decode: uint32
scale: 0.1
powers:
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 10638 # Meter Phase A Active Power
type: input
decode: int32
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 10640 # Meter Phase B Active Power
type: input
decode: int32
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 10642 # Meter Phase C Active Power
type: input
decode: int32
currents:
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 10635 # Meter Phase A Current
type: input
decode: uint16
scale: 0.01
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 10636 # Meter Phase B Current
type: input
decode: uint16
scale: 0.01
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 10637 # Meter Phase C Current
type: input
decode: uint16
scale: 0.01
voltages:
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 10632 # Meter Phase A Voltage
type: input
decode: uint16
scale: 0.1
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 10633 # Meter Phase B Voltage
type: input
decode: uint16
scale: 0.1
- source: modbus
{{- include "modbus" . | indent 4 }}
register:
address: 10634 # Meter Phase C Voltage
type: input
decode: uint16
scale: 0.1
{{- end }}
{{- if eq .usage "pv" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 10183 # Total PV Power (W)
type: input
decode: int32
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 10026 # Total PV Generation (kWh)
type: input
decode: uint32
scale: 0.1
maxacpower: {{ .maxacpower }}
{{- end }}
{{- if eq .usage "battery" }}
power:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 10006 # Battery Power (W, positive = discharging, negative = charging)
type: input
decode: int32
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 10264 # Battery Total Discharge Energy (kWh)
type: input
decode: uint32
scale: 0.1
soc:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 10010 # SOC (%)
type: input
decode: uint16
{{- include "battery-params" . }}
{{- end }}