Solaredge Hybrid: clarify battery mode requirements (#13022)
This commit is contained in:
parent
9bc4c8eeae
commit
7345b4f509
1 changed files with 4 additions and 2 deletions
|
|
@ -8,10 +8,12 @@ requirements:
|
|||
description:
|
||||
de: |
|
||||
Nur ein System kann und darf zeitgleich eine Modbus TCP-Verbindung zum Wechselrichter haben!
|
||||
Für die optionale Batteriesteuerung muss StorageConf_CtrlMode (0xE004) auf 4 "Remote" stehen.
|
||||
Für die optionale Batteriesteuerung muss StorageConf_CtrlMode (0xE004) auf 4 "Remote" stehen,
|
||||
sowie der Batteriemodus "Nutzungszeit" aktiv sein.
|
||||
en: |
|
||||
Only one system can and may have a Modbus TCP connection to the inverter at the same time!
|
||||
For optional battery control, StorageConf_CtrlMode (0xE004) must be set to 4 "Remote".
|
||||
For optional battery control, StorageConf_CtrlMode (0xE004) must be set to 4 "Remote" and
|
||||
battery mode must be set to "Time of Use".
|
||||
params:
|
||||
- name: usage
|
||||
choice: ["grid", "pv", "battery"]
|
||||
|
|
|
|||