template: fronius-argeno
products:
- brand: Fronius
description:
generic: Argeno
requirements:
description:
de: |
Modbus TCP muss am Wechselrichter aktiviert sein (Konfiguration → Kommunikation → Ethernet → Modbus TCP/UDP). Für den Netzzähler siehe Template „Fronius Smart Meter IP" — der Argeno nutzt den Smart Meter IP als eigenständiges Netzwerkgerät.
en: |
Modbus TCP must be enabled on the inverter (Configuration → Communication → Ethernet → Modbus TCP/UDP). For the grid meter see the "Fronius Smart Meter IP" template — the Argeno uses the Smart Meter IP as a standalone network device.
params:
- name: usage
choice: ["pv"]
- name: host
- name: port
default: 502
- name: maxacpower
render: |
type: custom
# Fronius Argeno: AC output via SunSpec inverter model 113 (float, primary)
# on unit 1; 103 (int+sf) as fallback for potential firmware variants. Unlike GEN24, PV must NOT be
# read from model 160 DC channels: the Argeno's modular power stages report
# only a fraction of plant output there (verified on-site: 160-based read
# showed 6.5 kW while actual AC output was 31.7 kW).
power:
source: sunspec
uri: {{ joinHostPort .host .port }}
id: 1
value:
- 113:W
- 103:W
energy:
source: sunspec
uri: {{ joinHostPort .host .port }}
id: 1
value:
- 113:WH
- 103:WH
scale: 0.001
maxacpower: {{ .maxacpower }} # W

View file

@ -0,0 +1,105 @@
template: fronius-smart-meter-ip
products:
- brand: Fronius
description:
generic: Smart Meter IP
requirements:
description:
de: |
Modbus TCP muss in der Weboberfläche des Zählers aktiviert sein (Einstellungen → Datenschnittstellen → Modbus (TCP und RTU)). Der Zähler wird direkt über seine eigene IP-Adresse ausgelesen, nicht über den Wechselrichter.
en: |
Modbus TCP must be enabled in the meter's web interface (Settings → Data interfaces → Modbus (TCP and RTU)). The meter is read directly via its own IP address, not through the inverter.
params:
- name: usage
choice: ["grid"]
- name: host
- name: port
default: 502
- name: id
default: 1
advanced: true
render: |
type: custom
# Fronius Smart Meter IP (63A-1, 63A-3, 5kA-3): standalone LAN/WLAN meter.
# SunSpec model 213 (float, primary) on unit 1; 203 (int+sf) as fallback
# for potential firmware variants.
power:
source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:W
- 203:W
energy:
source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:TotWhImp
- 203:TotWhImp
scale: 0.001
returnenergy:
source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:TotWhExp
- 203:TotWhExp
scale: 0.001
currents:
- source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:AphA
- 203:AphA
- source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:AphB
- 203:AphB
- source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:AphC
- 203:AphC
voltages:
- source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:PhVphA
- 203:PhVphA
- source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:PhVphB
- 203:PhVphB
- source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:PhVphC
- 203:PhVphC
powers:
- source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:WphA
- 203:WphA
- source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:WphB
- 203:WphB
- source: sunspec
uri: {{ joinHostPort .host .port }}
id: {{ .id }}
value:
- 213:WphC
- 203:WphC