Goodwe: add curtailment (BC) (#32795)
This commit is contained in:
parent
f0c8c18ad2
commit
91512a77b4
1 changed files with 69 additions and 1 deletions
|
|
@ -3,7 +3,7 @@ products:
|
|||
- brand: GoodWe
|
||||
description:
|
||||
generic: ET/EH/BH/BT Hybrid Inverter
|
||||
capabilities: ["battery-control"]
|
||||
capabilities: ["battery-control", "curtail"]
|
||||
params:
|
||||
- name: usage
|
||||
choice: ["grid", "pv", "battery"]
|
||||
|
|
@ -12,6 +12,7 @@ params:
|
|||
baudrate: 9600
|
||||
id: 247
|
||||
- name: maxacpower
|
||||
required: true
|
||||
- name: battery
|
||||
default: 1
|
||||
type: choice
|
||||
|
|
@ -197,6 +198,73 @@ render: |
|
|||
decode: uint32nan
|
||||
scale: 0.1
|
||||
maxacpower: {{ .maxacpower }} # W
|
||||
# GoodWe only has a single, global feed-in limit for the whole system (registers 47509/47510),
|
||||
# there is no per-string curtailment.
|
||||
curtail: # limit feed-in to given percent of nominal (100 % = maxacpower)
|
||||
source: switch
|
||||
switch:
|
||||
- case: 100 # uncurtailed
|
||||
set:
|
||||
source: const
|
||||
value: 0 # disable limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 8 }}
|
||||
register:
|
||||
address: 47509 # Feed-in power limit enable
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
default:
|
||||
source: sequence
|
||||
set:
|
||||
# write the limit before enabling it, the device must not apply a stale value
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 6 }}
|
||||
register:
|
||||
address: 47510 # Feed-in power limit, W
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
scale: {{ divf (maxf .maxacpower 1) 100 }} # % to W
|
||||
- source: const
|
||||
value: 1 # enable limit
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 8 }}
|
||||
register:
|
||||
address: 47509
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
curtailed: # allowed feed-in as percent of nominal, derived from feed-in power limit
|
||||
source: go
|
||||
in:
|
||||
- name: ena
|
||||
type: int
|
||||
config:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 6 }}
|
||||
register:
|
||||
address: 47509 # Feed-in power limit enable
|
||||
type: holding
|
||||
decode: uint16
|
||||
- name: w
|
||||
type: float
|
||||
config:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 6 }}
|
||||
register:
|
||||
address: 47510 # Feed-in power limit, W
|
||||
type: holding
|
||||
decode: uint16
|
||||
script: |
|
||||
percent := 100.0
|
||||
if ena != 0 {
|
||||
percent = w * 100 / {{ maxf .maxacpower 1 }}
|
||||
}
|
||||
p := int(percent + 0.5)
|
||||
if p > 100 {
|
||||
p = 100
|
||||
}
|
||||
p
|
||||
{{- end }}
|
||||
{{- if eq .usage "battery" }}
|
||||
power:
|
||||
|
|
|
|||