Solax: fix registers and unify X1/X3 G3/G4 (#4022)
This commit is contained in:
parent
640242bf94
commit
92611a7e57
2 changed files with 34 additions and 15 deletions
|
|
@ -1,12 +1,13 @@
|
|||
template: solax-x3
|
||||
template: solax
|
||||
covers: ["solax-x1", "solax-x3"]
|
||||
products:
|
||||
- brand: Solax
|
||||
description:
|
||||
generic: Hybrid X3
|
||||
generic: Hybrid X1/X3 G3/G4
|
||||
requirements:
|
||||
description:
|
||||
de: Der Solax Inverter muss via Ethernet an das lokale Netzwerk angeschlossen sein.
|
||||
en: The Solax inverter has to be connected to the local network via ethernet.
|
||||
de: Der Solax Hybrid Inverter muss via Ethernet an das lokale Netzwerk angeschlossen sein.
|
||||
en: The Solax Hybrid inverter has to be connected to the local network via ethernet.
|
||||
guidedsetup:
|
||||
enable: true
|
||||
params:
|
||||
|
|
@ -24,10 +25,19 @@ render: |
|
|||
uri: {{ .host }}:{{ .port }}
|
||||
id: 1
|
||||
register: # manual non-sunspec register configuration
|
||||
address: 192 #(see Hybrid.X1.X3-G3.ModbusTCP.RTU.V3.21-.English.pdf)
|
||||
address: 70 # 0x0046 feedin_power(meter)
|
||||
type: input
|
||||
decode: int32s
|
||||
scale: -1
|
||||
energy:
|
||||
source: modbus
|
||||
uri: {{ .host }}:{{ .port }}
|
||||
id: 1
|
||||
register: # manual non-sunspec register configuration
|
||||
address: 74 # 0x004A consum_energy_total(meter)
|
||||
type: input
|
||||
decode: uint32s
|
||||
scale: 10
|
||||
{{- end }}
|
||||
{{- if eq .usage "pv" }}
|
||||
source: calc
|
||||
|
|
@ -36,23 +46,32 @@ render: |
|
|||
uri: {{ .host }}:{{ .port }}
|
||||
id: 1
|
||||
register: # manual non-sunspec register configuration
|
||||
address: 10 #(see Hybrid.X1.X3-G3.ModbusTCP.RTU.V3.21-.English.pdf)
|
||||
address: 10 # 0x000A Powerdc1
|
||||
type: input
|
||||
decode: uint16
|
||||
- source: modbus
|
||||
uri: {{ .host }}:{{ .port }}
|
||||
id: 1
|
||||
register: # manual non-sunspec register configuration
|
||||
address: 11 #(see Hybrid.X1.X3-G3.ModbusTCP.RTU.V3.21-.English.pdf)
|
||||
address: 11 # 0x000B Powerdc2
|
||||
type: input
|
||||
decode: uint16
|
||||
energy:
|
||||
source: modbus
|
||||
uri: {{ .host }}:{{ .port }}
|
||||
id: 1
|
||||
register: # manual non-sunspec register configuration
|
||||
address: 148 # 0x0094 SolarEnergyTotal
|
||||
type: input
|
||||
decode: uint32s
|
||||
scale: 10
|
||||
{{- end }}
|
||||
{{- if eq .usage "battery" }}
|
||||
source: modbus
|
||||
uri: {{ .host }}:{{ .port }}
|
||||
id: 1
|
||||
register: # manual non-sunspec register configuration
|
||||
address: 22 #(see Hybrid.X1.X3-G3.ModbusTCP.RTU.V3.21-.English.pdf)
|
||||
address: 22 # 0x0016 Batpower_Charge1
|
||||
type: input
|
||||
decode: int16
|
||||
scale: -1
|
||||
|
|
@ -61,7 +80,7 @@ render: |
|
|||
uri: {{ .host }}:{{ .port }}
|
||||
id: 1
|
||||
register:
|
||||
address: 28 #(see Hybrid.X1.X3-G3.ModbusTCP.RTU.V3.21-.English.pdf)
|
||||
address: 28 # 0x001C Battery Capacity
|
||||
type: input
|
||||
decode: Uint16
|
||||
decode: uint16
|
||||
{{- end }}
|
||||
|
|
@ -1,27 +1,27 @@
|
|||
product:
|
||||
brand: Solax
|
||||
description: Hybrid X3
|
||||
description: Hybrid X1/X3 G3/G4
|
||||
description: |
|
||||
Der Solax Inverter muss via Ethernet an das lokale Netzwerk angeschlossen sein.
|
||||
Der Solax Hybrid Inverter muss via Ethernet an das lokale Netzwerk angeschlossen sein.
|
||||
render:
|
||||
- usage: grid
|
||||
default: |
|
||||
type: template
|
||||
template: solax-x3
|
||||
template: solax
|
||||
usage: grid
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port
|
||||
- usage: pv
|
||||
default: |
|
||||
type: template
|
||||
template: solax-x3
|
||||
template: solax
|
||||
usage: pv
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port
|
||||
- usage: battery
|
||||
default: |
|
||||
type: template
|
||||
template: solax-x3
|
||||
template: solax
|
||||
usage: battery
|
||||
host: 192.0.2.2 # IP-Adresse oder Hostname
|
||||
port: 502 # Port
|
||||