From 9656e941d71f6f9e8051cf540f6c75c09fc0dd22 Mon Sep 17 00:00:00 2001 From: Carsten Schlipf Date: Wed, 18 Dec 2024 11:01:36 +0100 Subject: [PATCH] Sofarsolar G3: add default energy storage mode (#17777) --- templates/definition/meter/sofarsolar-g3.yaml | 9 ++++++++- 1 file changed, 8 insertions(+), 1 deletion(-) diff --git a/templates/definition/meter/sofarsolar-g3.yaml b/templates/definition/meter/sofarsolar-g3.yaml index 01c622e0a..be14cbdba 100644 --- a/templates/definition/meter/sofarsolar-g3.yaml +++ b/templates/definition/meter/sofarsolar-g3.yaml @@ -29,6 +29,13 @@ params: deprecated: true - name: capacity advanced: true + - name: defaultmode + description: + de: Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus) + en: Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) + default: 0 # self use + usages: ["battery"] + advanced: true # battery control - name: minsoc type: int @@ -150,7 +157,7 @@ render: | - case: 1 # normal set: source: const - value: 0 # self-use + value: {{ .defaultmode }} # set back to default energy storage mode set: source: ignore error: "modbus: response data size '18' does not match count '4'"