Viessmann: remove 'target temperature' parameter (#22325)
This commit is contained in:
parent
5b270063e0
commit
9c7d8cd9b5
1 changed files with 18 additions and 31 deletions
|
|
@ -9,9 +9,9 @@ requirements:
|
|||
evcc: ["skiptest"]
|
||||
description:
|
||||
de: |
|
||||
Einmalige Warmwasserbereitung auf eine konfigurierbare Solltemperatur. Das Gerät entscheidet eigenständig, ob die Wärmepumpe oder die elektrische Zusatzheizung (falls vorhanden) genutzt wird.
|
||||
Einmalige Warmwasserbereitung. Das Gerät entscheidet eigenständig, ob die Wärmepumpe oder die elektrische Zusatzheizung (falls vorhanden) genutzt wird.
|
||||
en: |
|
||||
One-time hot water preparation to a configurable target temperature. The device automatically decides whether to use the heat pump or the auxiliary electric heater (if available).
|
||||
One-time hot water preparation. The device automatically decides whether to use the heat pump or the auxiliary electric heater (if available).
|
||||
params:
|
||||
- name: user
|
||||
required: true
|
||||
|
|
@ -139,14 +139,15 @@ params:
|
|||
en: typically `0`
|
||||
default: 0
|
||||
- name: target_temperature
|
||||
deprecated: true
|
||||
description:
|
||||
de: Zieltemperatur für Einmal-Warmwasser-Zubereitung
|
||||
en: Target temperature for one-time charge
|
||||
unit: °C
|
||||
help:
|
||||
de: max. 60°C
|
||||
en: max. 60°C
|
||||
required: true
|
||||
de: Parameter existiert nur aus historischen Gründen. Zieltemperatur kann in der ViCare App eingestellt werden (wird nicht von allen Anlagen unterstützt)
|
||||
en: Parameter only exists for historic reasons. Target Temperature can be configured in the ViCare app (not supported by all devices)
|
||||
required: false
|
||||
default: 45
|
||||
type: int
|
||||
render: |
|
||||
|
|
@ -186,32 +187,18 @@ render: |
|
|||
{ }
|
||||
- case: 3 # boost
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: http
|
||||
uri: https://api.viessmann.com/iot/v2/features/installations/{{.installation_id}}/gateways/{{.gateway_serial}}/devices/{{.device_id}}/features/heating.dhw.temperature.temp2/commands/setTargetTemperature
|
||||
method: POST
|
||||
headers:
|
||||
- content-type: application/json
|
||||
auth:
|
||||
source: viessmann
|
||||
user: {{ .user }}
|
||||
password: {{ .password }}
|
||||
clientid: {{ .clientid }}
|
||||
body: >
|
||||
{"temperature": {{.target_temperature}}}
|
||||
- source: http
|
||||
uri: https://api.viessmann.com/iot/v2/features/installations/{{.installation_id}}/gateways/{{.gateway_serial}}/devices/{{.device_id}}/features/heating.dhw.oneTimeCharge/commands/activate
|
||||
method: POST
|
||||
headers:
|
||||
- content-type: application/json
|
||||
auth:
|
||||
source: viessmann
|
||||
user: {{ .user }}
|
||||
password: {{ .password }}
|
||||
clientid: {{ .clientid }}
|
||||
body: >
|
||||
{ }
|
||||
source: http
|
||||
uri: https://api.viessmann.com/iot/v2/features/installations/{{.installation_id}}/gateways/{{.gateway_serial}}/devices/{{.device_id}}/features/heating.dhw.oneTimeCharge/commands/activate
|
||||
method: POST
|
||||
headers:
|
||||
- content-type: application/json
|
||||
auth:
|
||||
source: viessmann
|
||||
user: {{ .user }}
|
||||
password: {{ .password }}
|
||||
clientid: {{ .clientid }}
|
||||
body: >
|
||||
{ }
|
||||
- case: 1 # dimm
|
||||
set:
|
||||
source: error
|
||||
|
|
|
|||