Viessmann: remove 'target temperature' parameter (#22325)

This commit is contained in:
Michael Pollmeier 2025-07-13 16:06:12 +02:00 • committed by GitHub
parent 5b270063e0
commit 9c7d8cd9b5
No known key found for this signature in database
GPG key ID: B5690EEEBB952194

View file

@ -9,9 +9,9 @@ requirements:
evcc: ["skiptest"]
description:
de: |
Einmalige Warmwasserbereitung auf eine konfigurierbare Solltemperatur. Das Gerät entscheidet eigenständig, ob die Wärmepumpe oder die elektrische Zusatzheizung (falls vorhanden) genutzt wird.
Einmalige Warmwasserbereitung. Das Gerät entscheidet eigenständig, ob die Wärmepumpe oder die elektrische Zusatzheizung (falls vorhanden) genutzt wird.
en: |
One-time hot water preparation to a configurable target temperature. The device automatically decides whether to use the heat pump or the auxiliary electric heater (if available).
One-time hot water preparation. The device automatically decides whether to use the heat pump or the auxiliary electric heater (if available).
params:
- name: user
required: true
@ -139,14 +139,15 @@ params:
en: typically `0`
default: 0
- name: target_temperature
deprecated: true
description:
de: Zieltemperatur für Einmal-Warmwasser-Zubereitung
en: Target temperature for one-time charge
unit: °C
help:
de: max. 60°C
en: max. 60°C
required: true
de: Parameter existiert nur aus historischen Gründen. Zieltemperatur kann in der ViCare App eingestellt werden (wird nicht von allen Anlagen unterstützt)
en: Parameter only exists for historic reasons. Target Temperature can be configured in the ViCare app (not supported by all devices)
required: false
default: 45
type: int
render: |
@ -186,32 +187,18 @@ render: |
{ }
- case: 3 # boost
set:
source: sequence
set:
- source: http
uri: https://api.viessmann.com/iot/v2/features/installations/{{.installation_id}}/gateways/{{.gateway_serial}}/devices/{{.device_id}}/features/heating.dhw.temperature.temp2/commands/setTargetTemperature
method: POST
headers:
- content-type: application/json
auth:
source: viessmann
user: {{ .user }}
password: {{ .password }}
clientid: {{ .clientid }}
body: >
{"temperature": {{.target_temperature}}}
- source: http
uri: https://api.viessmann.com/iot/v2/features/installations/{{.installation_id}}/gateways/{{.gateway_serial}}/devices/{{.device_id}}/features/heating.dhw.oneTimeCharge/commands/activate
method: POST
headers:
- content-type: application/json
auth:
source: viessmann
user: {{ .user }}
password: {{ .password }}
clientid: {{ .clientid }}
body: >
{ }
source: http
uri: https://api.viessmann.com/iot/v2/features/installations/{{.installation_id}}/gateways/{{.gateway_serial}}/devices/{{.device_id}}/features/heating.dhw.oneTimeCharge/commands/activate
method: POST
headers:
- content-type: application/json
auth:
source: viessmann
user: {{ .user }}
password: {{ .password }}
clientid: {{ .clientid }}
body: >
{ }
- case: 1 # dimm
set:
source: error