@ -159,77 +159,73 @@ render: |
|
|||
scale: 0.1
|
||||
{{- end }}
|
||||
batterymode:
|
||||
source: watchdog
|
||||
timeout: 30s
|
||||
reset: 1 # reset watchdog on normal
|
||||
set:
|
||||
source: switch
|
||||
switch:
|
||||
- case: 1 # normal
|
||||
source: switch
|
||||
switch:
|
||||
- case: 1 # normal
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
source: sequence
|
||||
- source: const
|
||||
value: 1 # Normal operation mode
|
||||
set:
|
||||
- source: const
|
||||
value: 1 # Normal operation mode
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 12 }}
|
||||
register:
|
||||
address: 47511 # EMSPowerMode
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 0 # Maximum allowed power from Grid in W.
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 12 }}
|
||||
register:
|
||||
address: 47512 # EMSPowerSet [0-10000]
|
||||
type: writemultiple
|
||||
encoding: uint16
|
||||
- case: 2 # discharge hold
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 47511 # EMSPowerMode
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 0 # Maximum allowed power from Grid in W.
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 47512 # EMSPowerSet [0-10000]
|
||||
type: writemultiple
|
||||
encoding: uint16
|
||||
- case: 2 # discharge hold
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
source: sequence
|
||||
- source: const
|
||||
value: 2 # EMSPowerMode 2 "Charge-PV"-Mode. If EMSPowerSet=0 only PV is used to charge. Value 6 "Conserve"-Mode can be alternatively used.
|
||||
set:
|
||||
- source: const
|
||||
value: 2 # EMSPowerMode 2 "Charge-PV"-Mode. If EMSPowerSet=0 only PV is used to charge. Value 6 "Conserve"-Mode can be alternatively used.
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 12 }}
|
||||
register:
|
||||
address: 47511 # EMSPowerMode
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 0 # Maximum allowed power from Grid in W. If >0 battery will be charged also from Grid in Standby mode.
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 12 }}
|
||||
register:
|
||||
address: 47512 # EMSPowerSet [0-10000]
|
||||
type: writemultiple
|
||||
encoding: uint16
|
||||
- case: 3 # charge
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 47511 # EMSPowerMode
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 0 # Maximum allowed power from Grid in W. If >0 battery will be charged also from Grid in Standby mode.
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 47512 # EMSPowerSet [0-10000]
|
||||
type: writemultiple
|
||||
encoding: uint16
|
||||
- case: 3 # charge
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
source: sequence
|
||||
- source: const
|
||||
value: 2 # Charge from PV+AC according to the EMSPowerSet below. PV-Preferred. "Import-AC"-Mode (Value: 4) would prefer Grid-Power and reduce PV-Power generated.
|
||||
set:
|
||||
- source: const
|
||||
value: 2 # Charge from PV+AC according to the EMSPowerSet below. PV-Preferred. "Import-AC"-Mode (Value: 4) would prefer Grid-Power and reduce PV-Power generated.
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 12 }}
|
||||
register:
|
||||
address: 47511 # EMSPowerMode
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: {{ .maxchargepower }} # For charge battery mode: Maximum allowed power from Grid in W
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 12 }}
|
||||
register:
|
||||
address: 47512 # EMSPowerSet [0-10000]
|
||||
type: writemultiple
|
||||
encoding: uint16
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 47511 # EMSPowerMode
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: {{ .maxchargepower }} # For charge battery mode: Maximum allowed power from Grid in W
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 47512 # EMSPowerSet [0-10000]
|
||||
type: writemultiple
|
||||
encoding: uint16
|
||||
{{- include "battery-params" . }}
|
||||