@ -13,13 +13,9 @@ capabilities: ["battery-control"]
|
|||
requirements:
|
||||
description:
|
||||
de: |
|
||||
Um die aktive Ladesteuerung zum Netzladen nutzen zu können ist eine einmalige manuelle Einrichtung notwendig.
|
||||
Navigiere zu "System Settings" > "Storage Mode" im Wechselrichter Menü und aktiviere "Allow grid charging".
|
||||
Wenn die aktive Ladesteuerung dann die "Battery Reserve"-Einstellung anpasst, lädt der Wechselrichter die Batterie aus dem Netz bis zum hier konfigurierten Max SOC Wert auf (Standard: 95%).
|
||||
Die aktive Batteriesteuerung überschreibt die Wechselrichter Einstellungen "Allow grid charging" und "Battery Reserve SOC".
|
||||
en: |
|
||||
To use active battery control with grid charging, a one-time manual setup is required.
|
||||
Navigate to "System Settings" > "Storage Mode" in the inverter menu and enable "Allow grid charging".
|
||||
When active battery control adjusts the "Battery Reserve" setting, the inverter will charge the battery from the grid up to the Max SOC setting configured here (Default: 95%).
|
||||
Active battery control overrides the inverter settings "Allow grid charging" and "Battery Reserve SOC".
|
||||
params:
|
||||
- name: usage
|
||||
choice: ["grid", "pv", "battery"]
|
||||
|
|
@ -145,12 +141,74 @@ render: |
|
|||
address: 33139 # Battery capacity SOC
|
||||
type: input
|
||||
decode: uint16
|
||||
limitsoc:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 43024 # Battery Reserve Mode SOC
|
||||
type: writeholding
|
||||
encoding: uint16
|
||||
batterymode:
|
||||
source: switch
|
||||
switch:
|
||||
- case: 1 # normal
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: {{ .minsoc }}
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 43024 # Battery Reserve SOC
|
||||
type: writeholding
|
||||
decode: uint16
|
||||
- source: const
|
||||
value: 49 # Bits 0+4+5: Self Use Mode (1) + Battery Reserve (16) + Allow Grid Charge (32)
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 43110
|
||||
type: writeholding
|
||||
decode: uint16
|
||||
- case: 2 # hold
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: {{ .maxsoc }}
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 43024 # Battery Reserve SOC
|
||||
type: writeholding
|
||||
decode: uint16
|
||||
- source: const
|
||||
value: 17 # Bits 0+4: Self Use (1) + Battery Reserve (16)
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 43110
|
||||
type: writeholding
|
||||
decode: uint16
|
||||
- case: 3 # charge
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: {{ .maxsoc }}
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 43024 # Battery Reserve SOC
|
||||
type: writeholding
|
||||
decode: uint16
|
||||
- source: const
|
||||
value: 49 # Bits 0+4+5: Self Use Mode (1) + Battery Reserve (16) + Allow Grid Charge (32)
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 43110
|
||||
type: writeholding
|
||||
decode: uint16
|
||||
{{- include "battery-params" . }}
|
||||
{{- end }}
|
||||
|
|
|
|||