Meter (Solis Hybrid): drop coarse pv and battery energy registers (#30411)

This commit is contained in:
andig 2026-06-01 19:07:26 +02:00 • committed by GitHub
parent 34d59adbfe
commit b40f06d48c
No known key found for this signature in database
GPG key ID: B5690EEEBB952194
2 changed files with 12 additions and 28 deletions

View file

@ -97,13 +97,9 @@ render: |
type: input
address: 33057 # Total DC output power (PV Power)
decode: uint32
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33029 # Total energy generation
type: input
decode: uint32
# energy (33029 Total energy generation) intentionally omitted: the register
# has 1 kWh resolution, so the 15min energy history quantizes to 4 kW steps.
# History is integrated from power instead (see issue #30407).
maxacpower: {{ .maxacpower }} # W
{{- end }}
{{- if eq .usage "battery" }}
@ -129,13 +125,9 @@ render: |
scale: 2
- source: const
value: -1
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33165 # Battery total discharge energy
type: input
decode: uint32
# energy (33165 Battery total discharge energy) intentionally omitted: the
# register has 1 kWh resolution, so the 15min energy history quantizes to 4 kW
# steps. History is integrated from power instead (see issue #30407).
soc:
source: modbus
{{- include "modbus" . | indent 2 }}

View file

@ -84,13 +84,9 @@ render: |
type: input
address: 33057 # Total DC output power (PV Power)
decode: uint32
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33029 # Total energy generation
type: input
decode: uint32
# energy (33029 Total energy generation) intentionally omitted: the register
# has 1 kWh resolution, so the 15min energy history quantizes to 4 kW steps.
# History is integrated from power instead (see issue #30407).
maxacpower: {{ .maxacpower }} # W
{{- end }}
{{- if eq .usage "battery" }}
@ -102,13 +98,9 @@ render: |
address: 33149 # Battery power
decode: int32
scale: -1
energy:
source: modbus
{{- include "modbus" . | indent 2 }}
register:
address: 33165 # Battery total discharge energy
type: input
decode: uint32
# energy (33165 Battery total discharge energy) intentionally omitted: the
# register has 1 kWh resolution, so the 15min energy history quantizes to 4 kW
# steps. History is integrated from power instead (see issue #30407).
soc:
source: modbus
{{- include "modbus" . | indent 2 }}