Make energy readings optional (#91)
This commit is contained in:
parent
4cb76bdcf2
commit
b930f78549
3 changed files with 28 additions and 22 deletions
|
|
@ -203,8 +203,8 @@ Meters provide data about power and energy consumption. Available meter implemen
|
|||
model: sdm
|
||||
uri: rs485.fritz.box:23
|
||||
id: 2
|
||||
power: PowerL1
|
||||
energy: Export
|
||||
power: Power # reading as understood by MBMD, leave empty for power default value
|
||||
energy: Export # optional reading for total energy values, specify for charge meter
|
||||
```
|
||||
|
||||
- `sma`: SMA Home Manager and SMA Energy Meter. Power reading is configured out of the box but can be customizied if necessary. To obtain energy readings define the desired Obis code (Import Energy: "1:1.8.0", Export Energy: "1:2.8.0"):
|
||||
|
|
@ -214,7 +214,7 @@ Meters provide data about power and energy consumption. Available meter implemen
|
|||
type: sdm
|
||||
uri: 192.168.1.4
|
||||
power: # leave empty for mixed import/export energy
|
||||
energy: # leave empty to disable or chose obis 1:1.8.0/1:2.8.0
|
||||
energy: # leave empty to disable or choose obis 1:1.8.0/1:2.8.0
|
||||
```
|
||||
|
||||
- `default`: default meter implementation where meter readings- `power` and `energy` are configured using [plugin](#plugins)
|
||||
|
|
|
|||
|
|
@ -81,24 +81,24 @@ func NewModbusFromConfig(log *util.Logger, other map[string]interface{}) api.Met
|
|||
}
|
||||
}
|
||||
|
||||
// energy reading
|
||||
if cc.Energy == "" {
|
||||
cc.Energy = "Sum"
|
||||
}
|
||||
|
||||
energyM, err := meters.MeasurementString(cc.Energy)
|
||||
if err != nil {
|
||||
log.FATAL.Fatalf("invalid measurement for energy: %s", cc.Energy)
|
||||
}
|
||||
|
||||
// for RS485 check if producer supports the measurement
|
||||
m.opEnergy = rs485.Operation{IEC61850: energyM}
|
||||
if dev, ok := device.(*rs485.RS485); ok {
|
||||
m.opEnergy = modbus.RS485FindDeviceOp(dev, energyM)
|
||||
|
||||
if m.opEnergy.IEC61850 == 0 {
|
||||
log.FATAL.Fatalf("unsupported measurement for energy: %s", cc.Energy)
|
||||
// decorate energy reading
|
||||
if cc.Energy != "" {
|
||||
energyM, err := meters.MeasurementString(cc.Energy)
|
||||
if err != nil {
|
||||
log.FATAL.Fatalf("invalid measurement for energy: %s", cc.Energy)
|
||||
}
|
||||
|
||||
// for RS485 check if producer supports the measurement
|
||||
m.opEnergy = rs485.Operation{IEC61850: energyM}
|
||||
if dev, ok := device.(*rs485.RS485); ok {
|
||||
m.opEnergy = modbus.RS485FindDeviceOp(dev, energyM)
|
||||
|
||||
if m.opEnergy.IEC61850 == 0 {
|
||||
log.FATAL.Fatalf("unsupported measurement for energy: %s", cc.Energy)
|
||||
}
|
||||
}
|
||||
|
||||
return &ModbusEnergy{m}
|
||||
}
|
||||
|
||||
return m
|
||||
|
|
@ -131,7 +131,12 @@ func (m *Modbus) CurrentPower() (float64, error) {
|
|||
return m.floatGetter(m.opPower)
|
||||
}
|
||||
|
||||
// ModbusEnergy decorates Modbus with api.MeterEnergy interface
|
||||
type ModbusEnergy struct {
|
||||
*Modbus
|
||||
}
|
||||
|
||||
// TotalEnergy implements the Meter.TotalEnergy interface
|
||||
func (m *Modbus) TotalEnergy() (float64, error) {
|
||||
func (m *ModbusEnergy) TotalEnergy() (float64, error) {
|
||||
return m.floatGetter(m.opEnergy)
|
||||
}
|
||||
|
|
|
|||
|
|
@ -19,6 +19,7 @@ type Modbus struct {
|
|||
op rs485.Operation
|
||||
}
|
||||
|
||||
// ModbusSettings combine physical modbus configuration and MBMD model
|
||||
type ModbusSettings struct {
|
||||
Model string
|
||||
modbus.Connection `mapstructure:",squash"`
|
||||
|
|
@ -49,7 +50,7 @@ func NewModbusFromConfig(log *util.Logger, typ string, other map[string]interfac
|
|||
conn.Slave(cc.ID)
|
||||
err = device.Initialize(conn.ModbusClient())
|
||||
|
||||
// silence Kostal implementation errors
|
||||
// silence KOSTAL implementation errors
|
||||
if _, partial := err.(meters.SunSpecPartiallyInitialized); partial {
|
||||
err = nil
|
||||
}
|
||||
|
|
|
|||
Loading…