Add Solplanet hybrid inverter (Modbus TCP) (#32888)
This commit is contained in:
parent
ba8596be96
commit
bc38df1ed6
1 changed files with 201 additions and 0 deletions
201
templates/definition/meter/solplanet-modbus.yaml
Normal file
201
templates/definition/meter/solplanet-modbus.yaml
Normal file
|
|
@ -0,0 +1,201 @@
|
|||
template: solplanet-modbus
|
||||
products:
|
||||
- brand: Solplanet
|
||||
description:
|
||||
generic: Hybrid inverter (Modbus TCP)
|
||||
requirements:
|
||||
description:
|
||||
de: |
|
||||
Nur für Wechselrichter mit eigenem Modbus-TCP-Ethernet-Port (z.B. ASW-TH Serie, KACO Blueplanet Hybrid NH3, Port eth 5&6), Protokoll AISWEI "MB001_ASW GEN-Modbus" V2.1.7.
|
||||
Ältere Geräte ohne diesen Port benötigen stattdessen das `solplanet-ai-dongle` Template.
|
||||
Die Import-/Export-Zählerstände des Netzzählers (46443/46445) werden von dieser Firmware nicht über Modbus TCP bereitgestellt.
|
||||
Bei zwei Batteriepaketen (BMS1 + BMS2) je einen Batteriezähler mit Batteriespeichernummer 1 und 2 anlegen.
|
||||
en: |
|
||||
Only for inverters with a dedicated Modbus TCP ethernet port (e.g. ASW-TH series, KACO Blueplanet Hybrid NH3, port eth 5&6), protocol AISWEI "MB001_ASW GEN-Modbus" V2.1.7.
|
||||
Older devices without that port need the `solplanet-ai-dongle` template instead.
|
||||
The grid meter import/export energy counters (46443/46445) are not exposed over Modbus TCP by this firmware.
|
||||
With two battery packs (BMS1 + BMS2) add one battery meter each, using battery number 1 and 2.
|
||||
capabilities: ["battery-control", "curtail"]
|
||||
params:
|
||||
- name: usage
|
||||
choice: ["grid", "pv", "battery"]
|
||||
- name: modbus
|
||||
choice: ["tcpip"]
|
||||
port: 502
|
||||
id: 1
|
||||
- name: battery
|
||||
type: choice
|
||||
choice: [1, 2]
|
||||
required: true
|
||||
usages: ["battery"]
|
||||
description:
|
||||
de: Batteriespeichernummer
|
||||
en: Battery number
|
||||
- preset: battery-params
|
||||
- name: maxchargepower
|
||||
required: true
|
||||
render: |
|
||||
type: custom
|
||||
{{- if eq .usage "grid" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 6433 # 46434 total system power (smart meter)
|
||||
type: holding
|
||||
decode: int32
|
||||
{{- end }}
|
||||
{{- if eq .usage "pv" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 1600 # 31601 PV total power
|
||||
type: input
|
||||
decode: uint32
|
||||
energy:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 1604 # 31605 PV E-Total (0.1 kWh)
|
||||
type: input
|
||||
decode: uint32
|
||||
scale: 0.1
|
||||
curtail: # allowed feed-in power as percent of nominal
|
||||
source: sequence
|
||||
set:
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 6 }}
|
||||
register:
|
||||
address: 5402 # 45403 active power set (%Pn * 100)
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
scale: 100
|
||||
# active power control: disabled at 100% (unlimited), enabled while curtailed
|
||||
- source: switch
|
||||
switch:
|
||||
- case: 100 # uncurtailed
|
||||
set:
|
||||
source: const
|
||||
value: 0
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 4000 # 44001 active power control function
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
default:
|
||||
source: const
|
||||
value: 1
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 4000
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
curtailed: # the power limit only applies while active power control is enabled
|
||||
source: go
|
||||
in:
|
||||
- name: ena
|
||||
type: int
|
||||
config:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 8 }}
|
||||
register:
|
||||
address: 4000
|
||||
type: holding
|
||||
decode: uint16
|
||||
- name: percent
|
||||
type: int
|
||||
config:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 8 }}
|
||||
register:
|
||||
address: 5402
|
||||
type: holding
|
||||
decode: uint16
|
||||
scale: 0.01
|
||||
script: |
|
||||
res := 100
|
||||
if ena != 0 && percent > 0 && percent < 100 {
|
||||
res = percent
|
||||
}
|
||||
res
|
||||
{{- end }}
|
||||
{{- if eq .usage "battery" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: {{ if eq .battery "2" }}1751{{ else }}1618{{ end }} # 31752/31619 BMS2/1 battery power
|
||||
type: input
|
||||
decode: int32
|
||||
soc:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: {{ if eq .battery "2" }}1754{{ else }}1621{{ end }} # 31755/31622 BMS2/1 battery SoC
|
||||
type: input
|
||||
decode: uint16
|
||||
batterymode:
|
||||
source: switch
|
||||
switch:
|
||||
- case: 1 # normal
|
||||
set:
|
||||
source: const
|
||||
value: 2 # normal
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 10 }}
|
||||
register:
|
||||
address: 1103 # 41104 battery working mode
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- case: 2 # hold
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: 4 # custom
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 1103
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: 0
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 1152 # 41153 charge/discharge power, negative charges
|
||||
type: writesingle
|
||||
encoding: int16
|
||||
- case: 3 # charge
|
||||
set:
|
||||
source: sequence
|
||||
set:
|
||||
- source: const
|
||||
value: 4
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 1103
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- source: const
|
||||
value: {{ mul .maxchargepower -1 }}
|
||||
set:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 14 }}
|
||||
register:
|
||||
address: 1152
|
||||
type: writesingle
|
||||
encoding: int16
|
||||
{{- include "battery-params" . }}
|
||||
{{- end }}
|
||||