Varta: remove battery only template (#4929)

This commit is contained in:
andig 2022-10-24 21:28:04 +02:00 • committed by GitHub
parent 3a2b3f547b
commit be93681aff
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23
4 changed files with 8 additions and 67 deletions

View file

@ -1,42 +0,0 @@
template: varta-energiespeicher-battery-only
products:
- brand: VARTA
description:
de: Energiespeicher (kein PV-Sensor)
en: Energiespeicher (without PV Sensor)
params:
- name: usage
choice: ["grid", "battery"]
allinone: true
- name: host
- name: port
default: 502
render: |
type: custom
power:
source: modbus
uri: {{ .host }}:{{ .port }}
{{- if eq .usage "grid" }}
id: 255
register:
address: 1078 # grid power
type: holding
decode: int16
scale: -1
{{- end }}
{{- if eq .usage "battery" }}
id: 255
register:
address: 1066 # active power
type: holding
decode: int16
scale: -1
soc:
source: modbus
uri: {{ .host }}:{{ .port }}
id: 255
register:
address: 1068 # SOC
type: holding
decode: int16
{{- end }}

View file

@ -1,9 +1,10 @@
template: varta-energiespeicher
template: varta
covers: ["varta-energiespeicher", "varta-energiespeicher-battery-only"]
products:
- brand: VARTA
description:
de: Energiespeicher (mit PV-Sensor)
en: Energiespeicher (with PV Sensor)
de: pulse/ pulse neo/ element (PV nur verfügbar mit PV-Sensor)
en: pulse/ pulse neo/ element (PV only available with PV sensor)
params:
- name: usage
choice: ["grid", "pv", "battery"]

View file

@ -1,18 +0,0 @@
product:
brand: VARTA
description: Energiespeicher (kein PV-Sensor)
render:
- usage: grid
default: |
type: template
template: varta-energiespeicher-battery-only
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
- usage: battery
default: |
type: template
template: varta-energiespeicher-battery-only
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional

View file

@ -1,25 +1,25 @@
product:
brand: VARTA
description: Energiespeicher (mit PV-Sensor)
description: pulse/ pulse neo/ element (PV nur verfügbar mit PV-Sensor)
render:
- usage: grid
default: |
type: template
template: varta-energiespeicher
template: varta
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
- usage: pv
default: |
type: template
template: varta-energiespeicher
template: varta
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
- usage: battery
default: |
type: template
template: varta-energiespeicher
template: varta
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional