Shelly: drop grid energy and returnEnergy for 3-phase EM (#30534)
This commit is contained in:
parent
69e31deda0
commit
bfb55dc2c4
6 changed files with 38 additions and 6 deletions
|
|
@ -14,7 +14,7 @@ import (
|
|||
// Shelly meter considering usage
|
||||
type Shelly struct {
|
||||
implement.Caps
|
||||
shelly.Connection
|
||||
conn *shelly.Connection
|
||||
usage string
|
||||
}
|
||||
|
||||
|
|
@ -45,7 +45,14 @@ func NewShellyFromConfig(other map[string]any) (api.Meter, error) {
|
|||
return nil, err
|
||||
}
|
||||
|
||||
if phases, ok := c.Connection.Generation.(shelly.Phases); ok {
|
||||
// Three-phase Shelly energy meters count each phase separately (non-balanced),
|
||||
// making their totals unsuitable for bidirectional grid metering.
|
||||
if !(c.usage == "grid" && c.conn.IsThreePhase()) {
|
||||
implement.Has(c, implement.MeterEnergy(c.conn.TotalEnergy))
|
||||
implement.Has(c, implement.MeterReturnEnergy(c.conn.ReturnEnergy))
|
||||
}
|
||||
|
||||
if phases, ok := c.conn.Generation.(shelly.Phases); ok {
|
||||
implement.Has(c, implement.PhaseVoltages(phases.Voltages))
|
||||
implement.Has(c, implement.PhaseCurrents(phases.Currents))
|
||||
implement.Has(c, implement.PhasePowers(phases.Powers))
|
||||
|
|
@ -61,9 +68,9 @@ func NewShelly(uri, user, password, usage string, channel int, cache time.Durati
|
|||
return nil, err
|
||||
}
|
||||
c := &Shelly{
|
||||
Caps: implement.New(),
|
||||
Connection: *conn,
|
||||
usage: usage,
|
||||
Caps: implement.New(),
|
||||
conn: conn,
|
||||
usage: usage,
|
||||
}
|
||||
return c, nil
|
||||
}
|
||||
|
|
@ -72,7 +79,7 @@ var _ api.Meter = (*Shelly)(nil)
|
|||
|
||||
// CurrentPower implements the api.Meter interface
|
||||
func (c *Shelly) CurrentPower() (float64, error) {
|
||||
power, err := c.Connection.CurrentPower()
|
||||
power, err := c.conn.CurrentPower()
|
||||
if err != nil {
|
||||
return 0, err
|
||||
}
|
||||
|
|
|
|||
|
|
@ -18,6 +18,7 @@ type Generation interface {
|
|||
api.Meter
|
||||
api.MeterEnergy
|
||||
api.MeterReturnEnergy
|
||||
IsThreePhase() bool
|
||||
}
|
||||
|
||||
type Phases interface {
|
||||
|
|
|
|||
|
|
@ -144,6 +144,12 @@ func (c *gen1) ReturnEnergy() (float64, error) {
|
|||
return c.energy(energy) / 1000, nil
|
||||
}
|
||||
|
||||
// IsThreePhase reports whether the device is a three-phase energy meter.
|
||||
func (c *gen1) IsThreePhase() bool {
|
||||
res, err := c.status.Get()
|
||||
return err == nil && len(res.EMeters) == 3
|
||||
}
|
||||
|
||||
// gen1Energy in kWh
|
||||
func (c *gen1) energy(energy float64) float64 {
|
||||
// Gen 1 Shelly EM devices are providing Watt hours, Gen 1 Shelly PM devices are providing Watt minutes
|
||||
|
|
|
|||
|
|
@ -332,6 +332,11 @@ func (c *gen2) hasEMEndpoint() bool {
|
|||
return c.hasMethod("EM.GetStatus")
|
||||
}
|
||||
|
||||
// IsThreePhase reports whether the device is a three-phase energy meter
|
||||
func (c *gen2) IsThreePhase() bool {
|
||||
return c.hasEMEndpoint()
|
||||
}
|
||||
|
||||
// Gen2+ models using EM1.GetStatus endpoint for power and EM1Data.GetStatus for energy
|
||||
// https://shelly-api-docs.shelly.cloud/gen2/ComponentsAndServices/EM1#em1getstatus-example
|
||||
// https://shelly-api-docs.shelly.cloud/gen2/ComponentsAndServices/EM1Data#em1datagetstatus-example
|
||||
|
|
|
|||
Loading…