Charger (Plugchoice): fix CurrentPower reading 0 for externally started sessions (#32420)
This commit is contained in:
parent
edae1cc307
commit
c7c744f54e
1 changed files with 0 additions and 5 deletions
|
|
@ -237,11 +237,6 @@ var _ api.Meter = (*Plugchoice)(nil)
|
|||
|
||||
// CurrentPower implements the api.Meter interface
|
||||
func (c *Plugchoice) CurrentPower() (float64, error) {
|
||||
// Should be zero if not enabled
|
||||
if !c.enabled {
|
||||
return 0, nil
|
||||
}
|
||||
|
||||
res, err := c.powerG.Get()
|
||||
if err != nil {
|
||||
return 0, err
|
||||
|
|
|
|||
Loading…