Fix site.pvPower estimation for battery without pv (#32930)
This commit is contained in:
parent
50ff9ab777
commit
cc92f3938a
1 changed files with 4 additions and 3 deletions
|
|
@ -1054,9 +1054,10 @@ func (site *Site) sitePower(totalChargePower, flexiblePower float64) (float64, b
|
|||
residualPower = 100 // W
|
||||
}
|
||||
|
||||
// allow using grid and charge as estimate for pv power
|
||||
if site.pvMeters == nil {
|
||||
site.pvPower = totalChargePower - site.gridPower + residualPower
|
||||
// allow using grid, charge and battery power as estimate for pv power
|
||||
// needs a grid meter, otherwise grid power is itself derived from pv power (see above)
|
||||
if site.pvMeters == nil && site.gridMeter != nil {
|
||||
site.pvPower = totalChargePower - site.gridPower - site.battery.Power + residualPower
|
||||
if site.pvPower < 0 {
|
||||
site.pvPower = 0
|
||||
}
|
||||
|
|
|
|||