@ -1054,9 +1054,10 @@ func (site *Site) sitePower(totalChargePower, flexiblePower float64) (float64, b
residualPower = 100 // W
}
// allow using grid and charge as estimate for pv power
if site.pvMeters == nil {
site.pvPower = totalChargePower - site.gridPower + residualPower
// allow using grid, charge and battery power as estimate for pv power
// needs a grid meter, otherwise grid power is itself derived from pv power (see above)
if site.pvMeters == nil && site.gridMeter != nil {
site.pvPower = totalChargePower - site.gridPower - site.battery.Power + residualPower
if site.pvPower < 0 {
site.pvPower = 0
}