@ -0,0 +1,59 @@
template: ochsner-bwwp
products:
- brand: Ochsner
description:
generic: BWWP Genius 333
group: heating
params:
- name: host
- name: port
default: 502
- name: id
default: 1
# - name: tempsource
# type: choice
# choice: ["warmwater", "buffer"]
# description:
# de: Temperaturquelle (Warmwasser oder Pufferspeicher)
# en: Temperature source (warm water or buffer)
render: |
type: heatpump
setmaxpower:
source: const
value: 0
set:
source: modbus
uri: {{ .host }}:{{ .port }}
id: {{ .id }}
register:
address: 2201 # SUR Überschussleistung Auflösung 1 W
type: writesingle
decode: int16
power:
source: modbus
uri: {{ .host }}:{{ .port }}
id: {{ .id }}
register:
address: 2010 # aktuelle Leistungsaufnahme
type: holding
decode: int16
# {{- if .tempsource }}
# temp:
# source: modbus
# uri: {{ .host }}:{{ .port }}
# id: {{ .id }}
# register:
# address: 2200 # C1 Solltemperatur Auflösung 0,1°C
# type: holding
# decode: int16
# scale: 0.1
limittemp:
source: modbus
uri: {{ .host }}:{{ .port }}
id: {{ .id }}
register:
address: 2200 # C1 Solltemperatur Auflösung 0,1°C
type: holding
decode: int16
scale: 0.1