@ -13,14 +13,92 @@ requirements:
|
|||
das "Modbus"-Protokoll umgestellt werden.
|
||||
params:
|
||||
- name: usage
|
||||
choice: ["battery"]
|
||||
choice: ["grid", "pv", "battery"]
|
||||
- name: modbus
|
||||
choice: ["tcpip"]
|
||||
port: 502
|
||||
id: 1
|
||||
- name: maxacpower
|
||||
- preset: battery-params
|
||||
render: |
|
||||
type: custom
|
||||
{{- if eq .usage "grid" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 535 # Pgrid (S32, W, positive = import)
|
||||
type: input
|
||||
decode: int32
|
||||
currents:
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 510 # Igrid R (S16, 0.01 A)
|
||||
type: input
|
||||
decode: int16
|
||||
scale: 0.01
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 511 # Igrid S (S16, 0.01 A)
|
||||
type: input
|
||||
decode: int16
|
||||
scale: 0.01
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 512 # Igrid T (S16, 0.01 A)
|
||||
type: input
|
||||
decode: int16
|
||||
scale: 0.01
|
||||
powers:
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 529 # Pgrid R (S32, W)
|
||||
type: input
|
||||
decode: int32
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 531 # Pgrid S (S32, W)
|
||||
type: input
|
||||
decode: int32
|
||||
- source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 533 # Pgrid T (S32, W)
|
||||
type: input
|
||||
decode: int32
|
||||
energy:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 1020 # Efromgrid total (U32, 0.1 kWh)
|
||||
type: input
|
||||
decode: uint32
|
||||
scale: 0.1
|
||||
{{- end }}
|
||||
{{- if eq .usage "pv" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 553 # Ppv (U32, W)
|
||||
type: input
|
||||
decode: uint32
|
||||
energy:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 1026 # EPV total (U32, 0.1 kWh)
|
||||
type: input
|
||||
decode: uint32
|
||||
scale: 0.1
|
||||
maxacpower: {{ .maxacpower }}
|
||||
{{- end }}
|
||||
{{- if eq .usage "battery" }}
|
||||
power:
|
||||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
|
|
@ -44,3 +122,4 @@ render: |
|
|||
decode: uint32
|
||||
scale: 0.1
|
||||
{{- include "battery-params" . }}
|
||||
{{- end }}
|
||||
|
|
|
|||
Loading…