Add OVUM MIRA heat pump support (#30715)
This commit is contained in:
parent
56190ad535
commit
da22e7c687
1 changed files with 115 additions and 0 deletions
115
templates/definition/charger/ovum-mira.yaml
Normal file
115
templates/definition/charger/ovum-mira.yaml
Normal file
|
|
@ -0,0 +1,115 @@
|
|||
template: ovum-mira
|
||||
products:
|
||||
- brand: OVUM
|
||||
description:
|
||||
generic: MIRA
|
||||
group: heating
|
||||
capabilities: ["meter", "dim"]
|
||||
requirements:
|
||||
description:
|
||||
de: |
|
||||
Der Modbus-TCP-Server muss am Display unter „Einstellungen / Netzwerk“ aktiviert und der Modbus Login-Code deaktiviert (Wert 1) werden, da evcc die Login-Sequenz nicht durchführt.
|
||||
Die PV-Statusquelle muss am Display auf „EMS“ und die PV-Datenquelle auf die Leistungsvorgabe gestellt werden.
|
||||
Benötigt MIRA-Regler ab Softwareversion V1.1.3.
|
||||
en: |
|
||||
The Modbus TCP server must be enabled at the display under "Settings / Network" and the Modbus login code must be disabled (value 1) since evcc does not perform the login sequence.
|
||||
The PV status source must be set to "EMS" and the PV data source to the power setpoint at the display.
|
||||
Requires MIRA controller software V1.1.3 or later.
|
||||
params:
|
||||
- name: host
|
||||
- name: tempsource
|
||||
type: choice
|
||||
choice: ["warmwater", "buffer"]
|
||||
- name: wpmid
|
||||
type: int
|
||||
default: 111
|
||||
advanced: true
|
||||
description:
|
||||
de: Slave-ID Wärmepumpenmodul
|
||||
en: Heat pump module slave id
|
||||
help:
|
||||
de: Modbus Slave-ID des Wärmepumpenmoduls (WPM 1 = 111 … WPM 8 = 118)
|
||||
en: Modbus slave id of the heat pump module (WPM 1 = 111 … WPM 8 = 118)
|
||||
render: |
|
||||
type: sgready
|
||||
getmode:
|
||||
source: map
|
||||
values:
|
||||
0: 2 # Neutral -> normal
|
||||
1: 3 # Erhöhen -> boost
|
||||
2: 1 # Reduzieren -> dim
|
||||
get:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host "502" }}
|
||||
id: 110 # HSM
|
||||
register:
|
||||
address: 55070 # HSM_EMS_PVSTATUS
|
||||
type: holding
|
||||
encoding: int16
|
||||
setmode:
|
||||
source: map
|
||||
values:
|
||||
1: 2 # dim -> Reduzieren
|
||||
2: 0 # normal -> Neutral
|
||||
3: 1 # boost -> Erhöhen
|
||||
set:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host "502" }}
|
||||
id: 110 # HSM
|
||||
register:
|
||||
address: 55070 # HSM_EMS_PVSTATUS
|
||||
type: writesingle
|
||||
encoding: int16
|
||||
setmaxpower:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host "502" }}
|
||||
id: 110 # HSM
|
||||
register:
|
||||
address: 55076 # HSM_EMS_SOLLPOWER
|
||||
type: writemultiple
|
||||
encoding: int32
|
||||
power:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host "502" }}
|
||||
id: {{ .wpmid }} # WPM
|
||||
register:
|
||||
address: 56021 # WPM_WP_PWR
|
||||
type: holding
|
||||
encoding: float32
|
||||
scale: 1000 # kW -> W
|
||||
{{- if eq .tempsource "warmwater" }}
|
||||
temp:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host "502" }}
|
||||
id: 110 # HSM
|
||||
register:
|
||||
address: 55007 # WW_ACTUALTEMPO
|
||||
type: holding
|
||||
encoding: float32
|
||||
limittemp:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host "502" }}
|
||||
id: 110 # HSM
|
||||
register:
|
||||
address: 55002 # WW_SOLL_PV
|
||||
type: holding
|
||||
encoding: int16
|
||||
{{- end }}
|
||||
{{- if eq .tempsource "buffer" }}
|
||||
temp:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host "502" }}
|
||||
id: 110 # HSM
|
||||
register:
|
||||
address: 55026 # HPUF_PUOT
|
||||
type: holding
|
||||
encoding: float32
|
||||
limittemp:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host "502" }}
|
||||
id: 110 # HSM
|
||||
register:
|
||||
address: 55021 # PUFFER_SOLL_PV
|
||||
type: holding
|
||||
encoding: int16
|
||||
{{- end }}
|
||||