Planner: fix estimator disabled when soc provided by charger (#10698)
Some checks failed
Some checks failed
When the vehicles SoC is provided by the charger, the planner currently assumes that the EV is not charged at all. This can be reproduced by setting a target Soc to be identical to the current, and the planner will show a charge time that would be needed to reach the current Soc. The reason is `s.vehicleSoc` in `estimator.go` not being set as `publichSocAndRange()` exits before setting it.
This commit is contained in:
parent
5453820eb6
commit
dc650fd4f1
1 changed files with 1 additions and 1 deletions
|
|
@ -1384,7 +1384,7 @@ func (lp *Loadpoint) publishSocAndRange() {
|
|||
soc, err := lp.chargerSoc()
|
||||
|
||||
// guard for socEstimator removed by api
|
||||
if lp.socEstimator == nil || !lp.vehicleHasSoc() {
|
||||
if lp.socEstimator == nil || (!lp.vehicleHasSoc() && err != nil) {
|
||||
// This is a workaround for heaters. Without vehicle, the soc estimator is not initialized.
|
||||
// We need to check if the charger can provide soc and use it if available.
|
||||
if err == nil {
|
||||
|
|
|
|||