@ -9,8 +9,20 @@ products:
|
|||
group: heating
|
||||
requirements:
|
||||
description:
|
||||
de: Über das lokale Webinterface des AC•THOR muss der Wert für die "Zeitablauf Ansteuerung" auf einen Wert etwas größer der Intervall Zeit von evcc (z.B. + 5s) gesetzt werden.
|
||||
en: Use the local web interface of AC•THOR to set the value "Power timeout" to a value slightly higher (e.g. + 5s) than the interval time of evcc.
|
||||
de: |
|
||||
Über das lokale Webinterface des AC•THOR muss der Wert für die "Zeitablauf Ansteuerung" auf einen Wert etwas größer der Intervall Zeit von evcc (z.B. + 5s) gesetzt werden.
|
||||
Hat der Heizstab am geregelten Ausgang < 9 kW muss der Skalierungsfaktor wie folgt berechnet und gesetzt werden: `scale = 9000 / Nennleistung` des angeschlossenen Heizstabs.
|
||||
|
||||
Die Betriebsart M3: 9 + 9 kW mit einem zusätzlichen Heizstab am Relais-Ausgang wird unterstützt. Ohne Lastmessung mittels my-PV Meter muss "Last am Relais" im lokalen Webinterface des AC•THOR passend zur Nennleistung des Heizstabs am Relais gesetzt werden.
|
||||
Hat der Heizstab am geregelten Ausgang < 9 kW ist AC•THOR Firmware a0022200 oder höher erforderlich und der Wert für "Last am Relais" muss folgendermaßen mit dem Skalierungsfaktor umgerechnet werden:
|
||||
Last am Relais = Nennleistung des Heizstabs am Relais * Skalierungsfaktor
|
||||
en: |
|
||||
Use the local web interface of AC•THOR to set the value "Power timeout" to a value slightly higher (e.g. + 5s) than the interval time of evcc.
|
||||
If the heating element at the controlled output has <9kW, the scaling factor has to be calculated as follows: `scale = 9000 / nominal power` of the connected heater.
|
||||
|
||||
Operation mode M3: 9 + 9 kW with an additional heater connected to the relay output is supported. Without load measurement using my-PV meter, the "Load at relay" setting in the local web interface of the AC•THOR must be set to match the nominal power of the heating element at the relay.
|
||||
If the heater at the controlled output has <9kW, AC•THOR firmware a0022200 or higher is required and the value for "Load at relay" must be converted using the scaling factor as follows:
|
||||
Load at relay = nominal power of the heater at the relay * scale factor
|
||||
evcc: ["sponsorship"]
|
||||
params:
|
||||
- name: modbus
|
||||
|
|
@ -22,8 +34,8 @@ params:
|
|||
type: float
|
||||
default: 1
|
||||
description:
|
||||
en: "Scale factor for power limit"
|
||||
de: "Skalierungsfaktor der Leistungsvorgabe"
|
||||
en: "Scale factor for power target value"
|
||||
render: |
|
||||
type: ac-thor
|
||||
{{- include "modbus" . }}
|
||||
|
|
|
|||