AlphaESS: fix pv energy (#28640)
This commit is contained in:
parent
3cec5ba4c1
commit
f6e4a5b312
1 changed files with 3 additions and 2 deletions
|
|
@ -34,6 +34,7 @@ render: |
|
|||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 18 # 0x12 Total energy consumed from grid (Grid)
|
||||
# 0x10 (address 16) Total energy feed to grid (Grid) - for future grid energy import/export split
|
||||
type: holding
|
||||
decode: uint32
|
||||
scale: 0.01
|
||||
|
|
@ -110,10 +111,10 @@ render: |
|
|||
source: modbus
|
||||
{{- include "modbus" . | indent 2 }}
|
||||
register:
|
||||
address: 16 # 0x10 Total energy feed to Grid (Grid Meter)
|
||||
address: 1086 # 0x43E Inverter Total PV Energy
|
||||
type: holding
|
||||
decode: uint32
|
||||
scale: 0.01
|
||||
scale: 0.1
|
||||
maxacpower: {{ .maxacpower }}
|
||||
{{- end }}
|
||||
{{- if eq .usage "battery" }}
|
||||
|
|
|
|||
Loading…