From f7308513a72d9e40977074ada65516267a7fc750 Mon Sep 17 00:00:00 2001 From: RTTTC <94727758+RTTTC@users.noreply.github.com> Date: Sun, 3 Apr 2022 11:20:52 +0300 Subject: [PATCH] Update huawei-dongle-powersensor.yaml (#3060) Clarify DC/AC for pv meter, add correct scale for battery meter --- templates/definition/meter/huawei-dongle-powersensor.yaml | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/templates/definition/meter/huawei-dongle-powersensor.yaml b/templates/definition/meter/huawei-dongle-powersensor.yaml index bd80d333b..f2b001616 100644 --- a/templates/definition/meter/huawei-dongle-powersensor.yaml +++ b/templates/definition/meter/huawei-dongle-powersensor.yaml @@ -71,7 +71,7 @@ render: | timeout: 10s connectdelay: 1s register: - address: 32064 # Input power + address: 32064 # Input power DC (if no battery in your system - for more precise readings use 32080 # Active generation power AC) type: holding decode: int32 {{- end }} @@ -86,6 +86,7 @@ render: | address: 37001 type: holding decode: int32 + scale: -1 soc: source: modbus {{include "modbus" . | indent 2}}