template: solvis
|
||||
products:
|
||||
- brand: Solvis
|
||||
description:
|
||||
generic: SolvisControl 2/3
|
||||
group: heating
|
||||
capabilities: ["meter"]
|
||||
requirements:
|
||||
description:
|
||||
de: |
|
||||
Modbus TCP muss am SolvisControl unter „Einstellungen / Netzwerk“ aktiviert sein.
|
||||
Die Ansteuerung erfolgt über die Warmwasser-Solltemperatur.
|
||||
Eine Leistungsreduzierung (dim) unterstützt der Regler nicht.
|
||||
en: |
|
||||
Modbus TCP must be enabled at the SolvisControl under "Settings / Network".
|
||||
Control is done via the hot water target temperature.
|
||||
The controller does not support power reduction (dim).
|
||||
params:
|
||||
- name: host
|
||||
- name: port
|
||||
default: 502
|
||||
- name: tempnormal
|
||||
type: int
|
||||
default: 48
|
||||
description:
|
||||
de: Solltemperatur Normalbetrieb
|
||||
en: Target temperature normal mode
|
||||
- name: tempboost
|
||||
type: int
|
||||
default: 60
|
||||
description:
|
||||
de: Solltemperatur Boost
|
||||
en: Target temperature boost
|
||||
- name: tempsource
|
||||
required: true
|
||||
type: choice
|
||||
choice: ["warmwater", "buffer"]
|
||||
default: warmwater
|
||||
render: |
|
||||
type: sgready
|
||||
# The controller has no mode register, the mode is tracked by evcc.
|
||||
# It could be read back from 2305:
|
||||
# getmode:
|
||||
# source: map
|
||||
# values:
|
||||
# {{ .tempnormal }}: 2
|
||||
# {{ .tempboost }}: 3
|
||||
# get:
|
||||
# source: modbus
|
||||
# uri: {{ joinHostPort .host .port }}
|
||||
# id: 1
|
||||
# register:
|
||||
# address: 2305
|
||||
# type: holding
|
||||
# encoding: uint16
|
||||
setmode:
|
||||
source: switch
|
||||
switch:
|
||||
- case: 2 # normal
|
||||
set:
|
||||
source: const
|
||||
value: {{ .tempnormal }}
|
||||
set:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host .port }}
|
||||
id: 1
|
||||
register:
|
||||
address: 2305 # Warmwasser Solltemperatur
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- case: 3 # boost
|
||||
set:
|
||||
source: const
|
||||
value: {{ .tempboost }}
|
||||
set:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host .port }}
|
||||
id: 1
|
||||
register:
|
||||
address: 2305 # Warmwasser Solltemperatur
|
||||
type: writesingle
|
||||
encoding: uint16
|
||||
- case: 1 # dim
|
||||
set:
|
||||
source: error
|
||||
error: ErrNotAvailable
|
||||
power:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host .port }}
|
||||
id: 1
|
||||
register:
|
||||
address: 33545 # Wärmepumpe Leistungsaufnahme elektrisch
|
||||
type: holding
|
||||
encoding: uint16
|
||||
scale: 100 # 0.1 kW -> W
|
||||
temp:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host .port }}
|
||||
id: 1
|
||||
register:
|
||||
address: {{ if eq .tempsource "warmwater" }}33025{{ else }}33024{{ end }} # 33025 Warmwasser S2, 33024 Warmwasserpuffer S1
|
||||
type: input
|
||||
encoding: int16
|
||||
scale: 0.1
|
||||
limittemp:
|
||||
source: modbus
|
||||
uri: {{ joinHostPort .host .port }}
|
||||
id: 1
|
||||
register:
|
||||
address: 2305 # Warmwasser Solltemperatur
|
||||
type: holding
|
||||
encoding: uint16
|
||||
{{ include "heatpumpswitch" . }}
|
||||