Revert "Loadpoint: set internal current to 0 when disabling charger"

This reverts commit 4249372551.
This commit is contained in:
andig 2024-08-03 13:30:29 +02:00
parent 4249372551
commit faa9d580d3

View file

@ -862,11 +862,6 @@ func (lp *Loadpoint) setLimit(chargeCurrent float64) error {
lp.setAndPublishEnabled(enabled)
lp.chargerSwitched = lp.clock.Now()
// ensure we always re-set current when enabling charger
if !enabled {
lp.chargeCurrent = 0
}
lp.bus.Publish(evChargeCurrent, chargeCurrent)
// start/stop vehicle wake-up timer