Sigenergy: add battery control (#24426)
This commit is contained in:
parent
4718e5f90f
commit
fb753b6e55
1 changed files with 21 additions and 0 deletions
|
|
@ -3,6 +3,7 @@ products:
|
|||
- brand: Sigenergy
|
||||
description:
|
||||
generic: Sigen Hybrid/Sigen PV Max/SigenStore EC
|
||||
capabilities: ["battery-control"]
|
||||
requirements:
|
||||
description:
|
||||
de: Der Elektriker muss die Funktion Modbus via TCP/IP in seiner Version der Sigen App aktivieren bevor diese Konfiguration funktional ist. Diese Option ist in der mySigen App für Kunden nicht verfügbar.
|
||||
|
|
@ -18,6 +19,12 @@ params:
|
|||
default: 1
|
||||
- name: capacity
|
||||
advanced: true
|
||||
- name: minsoc
|
||||
type: int
|
||||
advanced: true
|
||||
- name: maxsoc
|
||||
type: int
|
||||
advanced: true
|
||||
render: |
|
||||
type: custom
|
||||
{{- if eq .usage "grid" }}
|
||||
|
|
@ -102,5 +109,19 @@ render: |
|
|||
type: holding
|
||||
decode: uint16
|
||||
scale: 0.1
|
||||
limitsoc:
|
||||
source: convert
|
||||
convert: float2int
|
||||
set:
|
||||
source: modbus
|
||||
uri: {{ .host }}:{{ .port }}
|
||||
id: 247
|
||||
register:
|
||||
address: 40048 # Discharge Cut-Off SoC
|
||||
type: writeholding
|
||||
decode: uint16
|
||||
scale: 10
|
||||
capacity: {{ .capacity }} # kWh
|
||||
minsoc: {{ .minsoc }} # %
|
||||
maxsoc: {{ .maxsoc }} # %
|
||||
{{- end }}
|
||||
|
|
|
|||
Loading…