Add capacity option to all battery templates (#5725)

This commit is contained in:
andig 2023-01-17 21:59:07 +01:00 • committed by GitHub
parent 756ccddcb1
commit fb899d33ae
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23
104 changed files with 1186 additions and 298 deletions

View file

@ -427,6 +427,10 @@ func (c *CmdConfigure) processParams(templateItem *templates.Template, deviceCat
continue
}
if usageFilter != "" && len(param.Usages) > 0 && !slices.Contains(param.Usages, string(usageFilter)) {
continue
}
switch param.ValueType {
case templates.ParamValueTypeStringList:
values := c.processListInputConfig(param)

View file

@ -17,8 +17,17 @@
}
},
"oneOf": [
{"required": ["generic"]},
{"required": ["de", "en"]}
{
"required": [
"generic"
]
},
{
"required": [
"de",
"en"
]
}
],
"title": "LanguageText"
},
@ -30,7 +39,11 @@
"type": "array",
"items": {
"type": "string",
"enum": ["sponsorship", "eebus", "mqtt"]
"enum": [
"sponsorship",
"eebus",
"mqtt"
]
}
},
"description": {
@ -41,17 +54,31 @@
"format": "uri"
}
},
"anyOf":[
{"required": ["evcc"]},
{"required": ["description"]}
"anyOf": [
{
"required": [
"evcc"
]
},
{
"required": [
"description"
]
}
],
"title": "Requirements"
},
"ParamDevice": {
"anyOf": [
{"$ref": "#/definitions/ParamTemplate"},
{"$ref": "#/definitions/ParamUsage"},
{"$ref": "#/definitions/ParamModbus"}
{
"$ref": "#/definitions/ParamTemplate"
},
{
"$ref": "#/definitions/ParamUsage"
},
{
"$ref": "#/definitions/ParamModbus"
}
]
},
"ParamUsage": {
@ -66,7 +93,12 @@
"type": "array",
"items": {
"type": "string",
"enum": ["charge", "grid", "pv", "battery"]
"enum": [
"charge",
"grid",
"pv",
"battery"
]
}
},
"allinone": {
@ -91,7 +123,10 @@
"type": "array",
"items": {
"type": "string",
"enum": ["tcpip", "rs485"]
"enum": [
"tcpip",
"rs485"
]
}
},
"id": {
@ -102,10 +137,19 @@
},
"baudrate": {
"type": "integer",
"enum": [9600, 19200, 38400, 57600, 115200]
"enum": [
9600,
19200,
38400,
57600,
115200
]
},
"comset": {
"enum": [8E1, "8N1"]
"enum": [
8E1,
"8N1"
]
},
"help": {
"$ref": "#/definitions/LanguageText"
@ -152,7 +196,16 @@
},
"valuetype": {
"type": "string",
"enum": ["string", "bool", "number", "float", "int", "stringlist", "chargemodes", "duration"]
"enum": [
"string",
"bool",
"number",
"float",
"int",
"stringlist",
"chargemodes",
"duration"
]
},
"validvalues": {
"type": "array",
@ -183,8 +236,16 @@
}
},
"oneOf": [
{"required": ["name"]},
{"required": ["preset"]}
{
"required": [
"name"
]
},
{
"required": [
"preset"
]
}
],
"title": "ParamTemplate"
},
@ -203,6 +264,12 @@
"type": "string",
"minLength": 1
},
"usages": {
"type": "array",
"items": {
"type": "string"
}
},
"mask": {
"type": "boolean"
},
@ -223,7 +290,15 @@
},
"valuetype": {
"type": "string",
"enum": ["string", "bool", "number", "float", "stringlist", "chargemodes", "duration"]
"enum": [
"string",
"bool",
"number",
"float",
"stringlist",
"chargemodes",
"duration"
]
},
"validvalues": {
"type": "array",
@ -247,7 +322,9 @@
"$ref": "#/definitions/Requirements"
}
},
"required": ["name"],
"required": [
"name"
],
"title": "ParamDefaults"
},
"ParamDependency": {
@ -260,7 +337,11 @@
},
"check": {
"type": "string",
"enum": ["empty", "notempty", "equal"]
"enum": [
"empty",
"notempty",
"equal"
]
},
"value": {
"minLength": 1
@ -277,9 +358,15 @@
"value": "equal"
}
},
"required": ["value"]
"required": [
"value"
]
},
{"required": ["check"]}
{
"required": [
"check"
]
}
],
"title": "ParamDependency"
}

View file

@ -97,10 +97,11 @@ params:
de: Akkukapazität in kWh
en: Battery capacity in kWh
help:
de: Akku-Kapazität in kWh
de: Akkukapazität in kWh
en: Battery capacity in kWh
example: "50"
valuetype: float
usages: ["vehicle", "battery"]
- name: vin
description:
de: Fahrzeugidentifikationsnummer

View file

@ -11,6 +11,8 @@ params:
choice: ["rs485", "tcpip"]
baudrate: 9600
id: 85
- name: capacity
advanced: true
render: |
type: custom
{{- if eq .usage "grid" }}
@ -131,4 +133,7 @@ render: |
type: holding
decode: uint16
scale: 0.1
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -8,6 +8,8 @@ params:
- name: host
- name: port
default: 502
- name: capacity
advanced: true
render: |
type: custom
power:
@ -32,4 +34,7 @@ render: |
address: 40082 # Batterie-SOC in Prozent
type: holding
decode: uint16
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end}}

View file

@ -7,8 +7,6 @@ products:
description:
generic: SDM 72v2
params:
- name: usage
choice: ["grid", "pv", "battery", "charge"]
- name: modbus
choice: ["rs485"]
render: |

View file

@ -15,6 +15,8 @@ params:
default: 502
- name: integer
deprecated: true
- name: capacity
advanced: true
render: |
# reference: https://github.com/volkszaehler/mbmd/blob/master/meters/sunspec/models.go
{{- if eq .usage "grid" }}
@ -73,4 +75,7 @@ render: |
id: 1
model: sunspec
value: ChargeState
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -8,6 +8,8 @@ params:
choice: ["grid", "pv", "battery"]
allinone: true
- name: host
- name: capacity
advanced: true
render: |
type: custom
power:
@ -25,4 +27,7 @@ render: |
source: http
uri: http://{{ .host }}/solar_api/v1/GetPowerFlowRealtimeData.fcgi
jq: .Body.Data.Inverters."1".SOC
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -10,6 +10,8 @@ params:
choice: ["rs485", "tcpip"]
baudrate: 9600
id: 1
- name: capacity
advanced: true
render: |
type: custom
power:
@ -80,6 +82,9 @@ render: |
address: 1014 # SOC
type: input
decode: uint16
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
energy:
source: modbus
{{- include "modbus" . | indent 2 }}

View file

@ -13,6 +13,8 @@ params:
advanced: true
- name: modbus
choice: ["tcpip"]
- name: capacity
advanced: true
render: |
type: custom
{{- if eq .usage "grid" }}
@ -110,4 +112,7 @@ render: |
type: holding
decode: uint16nan
scale: 0.1
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -4,8 +4,6 @@ products:
description:
generic: B23
params:
- name: usage
choice: ["grid", "pv", "battery", "charge"]
- name: modbus
choice: ["rs485", "tcpip"]
render: |

View file

@ -8,6 +8,8 @@ params:
choice: ["grid", "pv", "battery"]
allinone: true
- name: host
- name: capacity
advanced: true
render: |
type: custom
power:
@ -36,4 +38,7 @@ render: |
uri: http://{{ .host }}/api/dxs.json?dxsEntries=33556229 # Battery SOC
# | ----------------------------- Bat SOC% --------- |
jq: (.dxsEntries[] | select(.dxsId==33556229) | .value )
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end -}}

View file

@ -17,6 +17,8 @@ params:
choice: ["tcpip"]
id: 71
port: 1502
- name: capacity
advanced: true
render: |
{{- if eq .usage "pv" }}
type: custom
@ -42,4 +44,7 @@ render: |
model: sunspec
power: 802:W # sunspec model 802 battery
soc: 802:SoC # sunspec model 802 battery
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -14,9 +14,14 @@ params:
help:
en: Registration number of the LG ESS HOME inverter.
de: Registriernummer des LG ESS HOME Wechselrichters.
- name: capacity
advanced: true
render: |
type: lgess
usage: {{ .usage }}
# uri and password are only required once if multiple lgess usages are defined
uri: https://{{ .host }}
password: {{ .registration }}
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}

View file

@ -11,6 +11,8 @@ params:
mask: true
default: user
advanced: true
- name: capacity
advanced: true
render: |
type: custom
power:
@ -29,6 +31,7 @@ render: |
user: x
password: {{ .password }}
jq: .value
{{- if eq .usage "battery" }}
soc:
source: http
uri: http://{{ .host }}/rest/channel/_sum/EssSoc
@ -37,3 +40,7 @@ render: |
user: x
password: {{ .password }}
jq: .value
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -8,8 +8,13 @@ params:
choice: ["grid", "pv", "battery"]
allinone: true
- name: host
- name: capacity
advanced: true
render: |
type: rct
uri: {{ .host }}
usage: {{ .usage }}
cache: 2s
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}

View file

@ -8,6 +8,8 @@ params:
choice: ["grid", "pv", "battery"]
allinone: true
- name: host
- name: capacity
advanced: true
render: |
type: custom
power:
@ -40,4 +42,7 @@ render: |
jq: .ENERGY.GUI_BAT_DATA_FUEL_CHARGE | sub("fl_"; "")
unpack: hex
decode: float32
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -16,6 +16,8 @@ params:
- name: host
- name: port
default: 502
- name: capacity
advanced: true
render: |
type: custom
{{- if eq .usage "pv" }}
@ -81,4 +83,7 @@ render: |
address: 30845 # Battery Soc, %
type: holding
decode: uint32nan
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -15,6 +15,8 @@ params:
help:
en: The Modbus TCP-Server needs to be enabled on this Smart Energy inverter
de: Der Modbus TCP-Server muss an diesem Smart Energy Wechselrichter aktiviert sein
- name: capacity
advanced: true
render: |
type: custom
power:
@ -58,4 +60,7 @@ render: |
address: 30845 # SMA Modbus Profile: Battery state of charge
type: holding
decode: uint32nan
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -13,9 +13,14 @@ params:
help:
en: Password for user group Standard
de: Passwort für Benutzergruppe Benutzer
- name: capacity
advanced: true
render: |
type: sma
uri: {{ .host }} # IP address or hostname
{{- if ne .password "" }}
password: {{ .password }} # optional
{{- end }}
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}

View file

@ -17,6 +17,8 @@ params:
port: 1502
- name: timeout
valuetype: duration
- name: capacity
advanced: true
render: |
type: custom
power:
@ -62,4 +64,7 @@ render: |
address: 62852 # Battery 1 State of Energy (SOE)
type: holding
decode: float32s
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -10,6 +10,8 @@ params:
- name: modbus
choice: ["tcpip"]
id: 1
- name: capacity
advanced: true
render: |
type: custom
power:
@ -45,4 +47,7 @@ render: |
address: 122 # Batterie Soc
type: input
decode: int16
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -10,6 +10,8 @@ params:
- name: host
- name: port
default: 8080
- name: capacity
advanced: true
render: |
type: custom
power:
@ -27,4 +29,7 @@ render: |
source: http
uri: http://{{ .host }}:{{ .port }}/
jq: .SData.SoC
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -12,6 +12,8 @@ params:
choice: ["grid", "pv", "battery"]
allinone: true
- name: host
- name: capacity
advanced: true
render: |
type: custom
power:
@ -29,4 +31,7 @@ render: |
source: http
uri: http://{{ .host }}/rest/kiwigrid/wizard/devices # EnergyManager
jq: .result.items[] | select(.deviceModel[].deviceClass == "com.kiwigrid.devices.solarwatt.MyReserve") | .tagValues.StateOfCharge.value
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -32,7 +32,9 @@ params:
en: Serial number
help:
de: Auf https://www.solaxcloud.com/#/inverter die Registriernummer hier eintragen.
en: Go to https://www.solaxcloud.com/#/inverter and take the value of registration number
en: Go to https://www.solaxcloud.com/#/inverter and take the value of registration number.
- name: capacity
advanced: true
render: |
type: custom
power:
@ -68,4 +70,7 @@ render: |
uri: https://www.eu.solaxcloud.com:9443/proxy/api/getRealtimeInfo.do?tokenId={{ .tokenid }}&sn={{ .serial}}
jq: .result.soc # Solax API inverter.DC.battery.energy.SOC
cache: 2m30s
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -22,16 +22,16 @@ params:
description:
generic: SolaxCloud TokenID
help:
de: Auf https://www.solaxcloud.com/#/api den Wert von "ObtaintokenID" hier eintragen.
en: Go to https://www.solaxcloud.com/#/api and take the value of "ObtaintokenID".
de: ObtaintokenID von https://www.solaxcloud.com/#/api verwenden.
en: Use the ObtaintokenID from https://www.solaxcloud.com/#/api.
- name: serial
required: true
description:
de: Seriennummer
en: Serial number
help:
de: Auf https://www.solaxcloud.com/#/inverter die Registriernummer hier eintragen.
en: Go to https://www.solaxcloud.com/#/inverter and take the value of registration number
de: Registriernummer von https://www.solaxcloud.com/#/inverter verwenden.
en: Use the registration number from https://www.solaxcloud.com/#/inverter.
render: |
type: custom
power:

View file

@ -14,6 +14,8 @@ params:
- name: modbus
choice: ["rs485", "tcpip"]
baudrate: 19200
- name: capacity
advanced: true
render: |
type: custom
power:
@ -73,4 +75,7 @@ render: |
address: 28 # 0x001C Battery Capacity
type: input
decode: uint16
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -11,6 +11,8 @@ params:
- name: host
- name: port
default: 8080
- name: capacity
advanced: true
render: |
type: custom
power:
@ -29,4 +31,7 @@ render: |
source: http
uri: http://{{ .host }}:{{ .port }}/api/v1/status
jq: .USOC
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -15,6 +15,8 @@ params:
- name: modbus
choice: ["rs485", "tcpip"]
baudrate: 9600
- name: capacity
advanced: true
render: |
type: custom
{{- if eq .usage "grid" }}
@ -95,4 +97,7 @@ render: |
type: input
decode: int16
scale: 0.1
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -20,6 +20,8 @@ params:
en: Verify Float/Integer setting in inverter
advanced: true
valuetype: bool
- name: capacity
advanced: true
render: |
{{- if eq .usage "grid" }}
type: modbus
@ -91,4 +93,7 @@ render: |
{{- include "modbus" . | indent 2 }}
model: sunspec
value: ChargeState
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -12,6 +12,8 @@ params:
- name: host
- name: port
default: 502
- name: capacity
advanced: true
render: |
type: custom
power:
@ -47,4 +49,7 @@ render: |
address: 1068 # SOC
type: holding
decode: int16
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -10,6 +10,8 @@ params:
- name: host
- name: port
default: 502
- name: capacity
advanced: true
render: |
type: custom
power:
@ -108,4 +110,7 @@ render: |
address: 843 # Soc
type: input
decode: uint16
{{- if ne .capacity "" }}
capacity: {{ .capacity }} # kWh
{{- end }}
{{- end }}

View file

@ -9,7 +9,6 @@ params:
default: car
advanced: true
- name: capacity
valuetype: float
- name: phases
advanced: true
- name: mode

View file

@ -26,6 +26,30 @@ render:
id: 85
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: alpha-ess-smile
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 85
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 85
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 85
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -50,6 +74,30 @@ render:
id: 85
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: alpha-ess-smile
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 85
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 85
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 85
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -74,3 +122,27 @@ render:
id: 85
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: alpha-ess-smile
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 85
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 85
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 85
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -8,6 +8,13 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: e3dc
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -15,6 +22,13 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: e3dc
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -22,3 +36,10 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: e3dc
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -2,65 +2,9 @@ product:
brand: Eastron
description: SDM 630
render:
- usage: grid
default: |
- default: |
type: template
template: eastron
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: pv
default: |
type: template
template: eastron
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: battery
default: |
type: template
template: eastron
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: charge
default: |
type: template
template: eastron
usage: charge
template: eastron
# RS485 via adapter (Modbus RTU)
modbus: rs485serial

View file

@ -2,65 +2,9 @@ product:
brand: Eastron
description: SDM 72v2
render:
- usage: grid
default: |
- default: |
type: template
template: eastron
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: pv
default: |
type: template
template: eastron
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: battery
default: |
type: template
template: eastron
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: charge
default: |
type: template
template: eastron
usage: charge
template: eastron
# RS485 via adapter (Modbus RTU)
modbus: rs485serial

View file

@ -9,6 +9,13 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: fronius-gen24
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -16,6 +23,13 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: fronius-gen24
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -23,3 +37,10 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: fronius-gen24
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -9,6 +9,13 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: fronius-gen24
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -16,6 +23,13 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: fronius-gen24
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -23,3 +37,10 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: fronius-gen24
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -8,15 +8,33 @@ render:
template: fronius-solarapi-v1
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: fronius-solarapi-v1
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
template: fronius-solarapi-v1
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: fronius-solarapi-v1
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
template: fronius-solarapi-v1
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: fronius-solarapi-v1
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -26,6 +26,30 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: growatt-hybrid
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -50,6 +74,30 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: growatt-hybrid
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -74,3 +122,27 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: growatt-hybrid
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -24,6 +24,7 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -46,6 +47,7 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -68,3 +70,4 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -2,83 +2,9 @@ product:
brand: Janitza
description: B23
render:
- usage: grid
default: |
- default: |
type: template
template: janitza-b23
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: pv
default: |
type: template
template: janitza-b23
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: battery
default: |
type: template
template: janitza-b23
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
- usage: charge
default: |
type: template
template: janitza-b23
usage: charge
template: janitza-b23
# RS485 via adapter (Modbus RTU)
modbus: rs485serial

View file

@ -8,15 +8,33 @@ render:
template: kostal-piko
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: kostal-piko
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
template: kostal-piko
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: kostal-piko
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
template: kostal-piko
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: kostal-piko
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -13,6 +13,17 @@ render:
id: 71
host: 192.0.2.2 # Hostname
port: 1502 # Port
advanced: |
type: template
template: kostal-plenticore
usage: pv
# Modbus TCP
modbus: tcpip
id: 71
host: 192.0.2.2 # Hostname
port: 1502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -24,3 +35,14 @@ render:
id: 71
host: 192.0.2.2 # Hostname
port: 1502 # Port
advanced: |
type: template
template: kostal-plenticore
usage: battery
# Modbus TCP
modbus: tcpip
id: 71
host: 192.0.2.2 # Hostname
port: 1502 # Port
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -9,6 +9,13 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
registration: DE200... # Registriernummer des LG ESS HOME Wechselrichters.
advanced: |
type: template
template: lg-ess-home-8-10
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
registration: DE200... # Registriernummer des LG ESS HOME Wechselrichters.
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -16,6 +23,13 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
registration: DE200... # Registriernummer des LG ESS HOME Wechselrichters.
advanced: |
type: template
template: lg-ess-home-8-10
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
registration: DE200... # Registriernummer des LG ESS HOME Wechselrichters.
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -23,3 +37,10 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
registration: DE200... # Registriernummer des LG ESS HOME Wechselrichters.
advanced: |
type: template
template: lg-ess-home-8-10
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
registration: DE200... # Registriernummer des LG ESS HOME Wechselrichters.
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -13,6 +13,7 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
password: user # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -25,6 +26,7 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
password: user # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -37,3 +39,4 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
password: user # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -13,6 +13,7 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
password: user # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -25,6 +26,7 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
password: user # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -37,3 +39,4 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
password: user # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen) # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -8,15 +8,33 @@ render:
template: rct-power
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: rct-power
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
template: rct-power
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: rct-power
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
template: rct-power
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: rct-power
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -8,15 +8,33 @@ render:
template: senec-home
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: senec-home
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
template: senec-home
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: senec-home
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
template: senec-home
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: senec-home
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -11,6 +11,13 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: sma-data-manager
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -18,6 +25,13 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: sma-data-manager
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -25,3 +39,10 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: sma-data-manager
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -13,6 +13,17 @@ render:
id: 3
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: sma-hybrid
usage: pv
# Modbus TCP
modbus: tcpip
id: 3
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -24,3 +35,14 @@ render:
id: 3
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: sma-hybrid
usage: battery
# Modbus TCP
modbus: tcpip
id: 3
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -9,6 +9,13 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
password: # Passwort für Benutzergruppe Benutzer # Optional
advanced: |
type: template
template: sma-inverter
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
password: # Passwort für Benutzergruppe Benutzer # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -16,3 +23,10 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
password: # Passwort für Benutzergruppe Benutzer # Optional
advanced: |
type: template
template: sma-inverter
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
password: # Passwort für Benutzergruppe Benutzer # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -29,6 +29,31 @@ render:
host: 192.0.2.2 # Hostname
port: 1502 # Port
timeout: 10s # Optional
advanced: |
type: template
template: solaredge-hybrid
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 1502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 1502 # Port
timeout: 10s # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -54,6 +79,31 @@ render:
host: 192.0.2.2 # Hostname
port: 1502 # Port
timeout: 10s # Optional
advanced: |
type: template
template: solaredge-hybrid
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 1502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 1502 # Port
timeout: 10s # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -79,3 +129,28 @@ render:
host: 192.0.2.2 # Hostname
port: 1502 # Port
timeout: 10s # Optional
advanced: |
type: template
template: solaredge-hybrid
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 1502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 1502 # Port
timeout: 10s # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -13,6 +13,17 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: solarmax-maxstorage
usage: grid
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -24,6 +35,17 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: solarmax-maxstorage
usage: pv
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -35,3 +57,14 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: solarmax-maxstorage
usage: battery
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -9,6 +9,13 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
advanced: |
type: template
template: solarwatt-myreserve-matrix
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -16,6 +23,13 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
advanced: |
type: template
template: solarwatt-myreserve-matrix
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -23,3 +37,10 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
advanced: |
type: template
template: solarwatt-myreserve-matrix
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -8,15 +8,33 @@ render:
template: solarwatt
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: solarwatt
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
template: solarwatt
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: solarwatt
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
template: solarwatt
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: solarwatt
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -8,15 +8,33 @@ render:
template: solarwatt
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: solarwatt
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
template: solarwatt
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: solarwatt
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
template: solarwatt
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
advanced: |
type: template
template: solarwatt
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -14,6 +14,13 @@ render:
usage: grid
tokenid: # Auf https://www.solaxcloud.com/#/api den Wert von "ObtaintokenID" hier eintragen.
serial: # Auf https://www.solaxcloud.com/#/inverter die Registriernummer hier eintragen.
advanced: |
type: template
template: solax-hybrid-cloud
usage: grid
tokenid: # Auf https://www.solaxcloud.com/#/api den Wert von "ObtaintokenID" hier eintragen.
serial: # Auf https://www.solaxcloud.com/#/inverter die Registriernummer hier eintragen.
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -21,6 +28,13 @@ render:
usage: pv
tokenid: # Auf https://www.solaxcloud.com/#/api den Wert von "ObtaintokenID" hier eintragen.
serial: # Auf https://www.solaxcloud.com/#/inverter die Registriernummer hier eintragen.
advanced: |
type: template
template: solax-hybrid-cloud
usage: pv
tokenid: # Auf https://www.solaxcloud.com/#/api den Wert von "ObtaintokenID" hier eintragen.
serial: # Auf https://www.solaxcloud.com/#/inverter die Registriernummer hier eintragen.
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -28,3 +42,10 @@ render:
usage: battery
tokenid: # Auf https://www.solaxcloud.com/#/api den Wert von "ObtaintokenID" hier eintragen.
serial: # Auf https://www.solaxcloud.com/#/inverter die Registriernummer hier eintragen.
advanced: |
type: template
template: solax-hybrid-cloud
usage: battery
tokenid: # Auf https://www.solaxcloud.com/#/api den Wert von "ObtaintokenID" hier eintragen.
serial: # Auf https://www.solaxcloud.com/#/inverter die Registriernummer hier eintragen.
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -12,5 +12,5 @@ render:
type: template
template: solax-inverter-cloud
usage: pv
tokenid: # Auf https://www.solaxcloud.com/#/api den Wert von "ObtaintokenID" hier eintragen.
serial: # Auf https://www.solaxcloud.com/#/inverter die Registriernummer hier eintragen.
tokenid: # ObtaintokenID von https://www.solaxcloud.com/#/api verwenden.
serial: # Registriernummer von https://www.solaxcloud.com/#/inverter verwenden.

View file

@ -26,6 +26,30 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: solax
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -50,6 +74,30 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: solax
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -74,3 +122,27 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: solax
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -26,6 +26,30 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: solax
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -50,6 +74,30 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: solax
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -74,3 +122,27 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: solax
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 19200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -9,6 +9,13 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
advanced: |
type: template
template: sonnenbatterie
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -16,6 +23,13 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
advanced: |
type: template
template: sonnenbatterie
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -23,3 +37,10 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
advanced: |
type: template
template: sonnenbatterie
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 8080 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -28,6 +28,30 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: sungrow-hybrid
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -52,6 +76,30 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: sungrow-hybrid
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -76,3 +124,27 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: sungrow-hybrid
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -24,6 +24,7 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
integer: # Einstellung Float/Integer im Wechselrichter überprüfen # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -46,6 +47,7 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
integer: # Einstellung Float/Integer im Wechselrichter überprüfen # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -68,3 +70,4 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
integer: # Einstellung Float/Integer im Wechselrichter überprüfen # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -9,6 +9,13 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: varta
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -16,6 +23,13 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: varta
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -23,3 +37,10 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: varta
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -9,6 +9,13 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: victron-energy
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: pv
default: |
type: template
@ -16,6 +23,13 @@ render:
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: victron-energy
usage: pv
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional
- usage: battery
default: |
type: template
@ -23,3 +37,10 @@ render:
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
advanced: |
type: template
template: victron-energy
usage: battery
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port # Optional
capacity: 50 # Akkukapazität in kWh # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WAUZZZ... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: audi
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WAUZZZ... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WBMW... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: bmw
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WBMW... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: carwings
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: citroen
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: cupra
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 27.4 # Akku-Kapazität in kWh # Optional
capacity: 27.4 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: dacia
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 27.4 # Akku-Kapazität in kWh # Optional
capacity: 27.4 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: ds
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: enyaq
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WAUZZZ... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: etron
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WAUZZZ... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,14 +8,14 @@ render:
title: # Wird in der Benutzeroberfläche angezeigt # Optional
akey:
token:
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: evnotify
title: # Wird in der Benutzeroberfläche angezeigt # Optional
akey:
token:
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
mode: # Möglich sind Off, Now, MinPV und PV, oder leer wenn keiner definiert werden soll # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: ZFAE... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
pin: # Optional
advanced: |
type: template
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: ZFAE... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WF0FXX... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: ford
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WF0FXX... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
language: en # 'de' für Deutsch und 'en' für Englisch # Optional
advanced: |
type: template
@ -18,7 +18,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -11,7 +11,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WVWZZZ... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: id
@ -19,7 +19,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WVWZZZ... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: jaguar-landrover
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: jaguar-landrover
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
language: en # 'de' für Deutsch und 'en' für Englisch # Optional
advanced: |
type: template
@ -18,7 +18,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WBMW... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: mini
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WBMW... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: nissan
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -10,7 +10,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
serial:
capacity: 4 # Akku-Kapazität in kWh # Optional
capacity: 4 # Akkukapazität in kWh # Optional
icon: scooter # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
advanced: |
type: template
@ -19,7 +19,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
serial:
capacity: 4 # Akku-Kapazität in kWh # Optional
capacity: 4 # Akkukapazität in kWh # Optional
icon: scooter # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
mode: # Möglich sind Off, Now, MinPV und PV, oder leer wenn keiner definiert werden soll # Optional
minSoc: 25 # Lade sofort mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand, wenn der Lademodus nicht auf 'Aus' steht # Optional

View file

@ -6,13 +6,13 @@ render:
type: template
template: offline
title: # Wird in der Benutzeroberfläche angezeigt # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: offline
title: # Wird in der Benutzeroberfläche angezeigt # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
mode: # Möglich sind Off, Now, MinPV und PV, oder leer wenn keiner definiert werden soll # Optional
minCurrent: 6 # Definiert die minimale Stromstärke pro angeschlossener Phase mit welcher das Fahrzeug geladen werden soll # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WP0... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: opel
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WP0... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -11,7 +11,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vehicleid:
capacity: 12 # Akku-Kapazität in kWh # Optional
capacity: 12 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: ovms
@ -19,7 +19,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vehicleid:
capacity: 12 # Akku-Kapazität in kWh # Optional
capacity: 12 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
mode: # Möglich sind Off, Now, MinPV und PV, oder leer wenn keiner definiert werden soll # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: peugeot
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: porsche
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WREN... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: renault
@ -16,7 +16,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: WREN... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: seat
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -10,7 +10,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: silence
@ -18,7 +18,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: scooter # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: skoda
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -9,7 +9,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 17.6 # Akku-Kapazität in kWh # Optional
capacity: 17.6 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: smart
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 17.6 # Akku-Kapazität in kWh # Optional
capacity: 17.6 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

View file

@ -16,7 +16,7 @@ render:
accessToken: # Siehe https://docs.evcc.io/docs/devices/vehicles#tesla
refreshToken: # Siehe https://docs.evcc.io/docs/devices/vehicles#tesla
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: tesla
@ -24,7 +24,7 @@ render:
accessToken: # Siehe https://docs.evcc.io/docs/devices/vehicles#tesla
refreshToken: # Siehe https://docs.evcc.io/docs/devices/vehicles#tesla
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
mode: # Möglich sind Off, Now, MinPV und PV, oder leer wenn keiner definiert werden soll # Optional

View file

@ -10,7 +10,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 10 # Akku-Kapazität in kWh # Optional
capacity: 10 # Akkukapazität in kWh # Optional
advanced: |
type: template
template: tronity
@ -18,7 +18,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 10 # Akku-Kapazität in kWh # Optional
capacity: 10 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
mode: # Möglich sind Off, Now, MinPV und PV, oder leer wenn keiner definiert werden soll # Optional

View file

@ -8,7 +8,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
vccapikey: # Volvo developer portal VCC API Key, siehe https://github.com/evcc-io/evcc/discussions/3677#discussioncomment-4106300
advanced: |
type: template
@ -17,7 +17,7 @@ render:
user: # Benutzerkonto (bspw. E-Mail Adresse, User Id, etc.)
password: # Passwort des Benutzerkontos (bei führenden Nullen bitte in einfache Hochkommata setzen)
vin: W... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
capacity: 50 # Akku-Kapazität in kWh # Optional
capacity: 50 # Akkukapazität in kWh # Optional
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können # Optional
icon: car # Darstellung in der UI. Mögliche Werte: bike, bus, car, heater, heatercooler, heatpump, moped, motorcycle, plug, scooter, tractor, van, waterheater # Optional
cache: 15m # Zeitintervall nach dem Daten erneut vom Fahrzeug abgefragt werden # Optional

Some files were not shown because too many files have changed in this diff Show more