If a limit has been set, a measurement is expected to provided within 15s. If this is not the case, then show a warning and return an error.
Also add support for the Elli Connect Pro internal meter again.
This should now lead to those EEBUS wallboxes not providing measurements, to fall back to the actual limit being assumed as being the current measurement. And the user is informed about non function metering in the wallbox.
- Update SHIP and EEBUS libraries to latest dev code
- Support IPv6 connections and devices only reporting IPv6 mDNS addresses
- Re-Add support for overwriting the IP address in the charger config, also added to the meter config (just in case)
- Check if sending the heartbeat even more often helps
- Use avahi as mDNS provider if available. this might help finding the Elli device after disconnections quicker and maybe even ones own mDNS entry better
- Fix a small bug with resetting recommendation limits to inactive when using VAS EVs