Naumann-Kai
98f2f904e3
Add qcells-hybrid-cloud ( #16736 )
2024-10-19 22:23:10 +02:00
andig
5949829117
Move MaxACPower hybrid setting to pv config ( #16735 )
2024-10-19 17:11:07 +02:00
Ante Karamatić
c89bfcc000
SolarEdge: add energy and currents ( #16675 )
...
Adding read outs of currents and produced energy for Solaredge inverters for a use case where they are not equiped with CTs.
2024-10-16 21:05:16 +02:00
maatinh
a0b40c1d63
Goodwe-hybrid: update Discharge-Mode ( #16649 )
...
Previously used Mode 8 is putting battery into standby where it would not charge or discharge.
Mode 2 uses all PV-Power to charge Battery and uses Grid-Power to power AC side. Discharging is prevented.
2024-10-16 14:29:27 +02:00
farcorben
f0d851a1d9
Solax/Fronius Gen24: add MaxACPower ( #16662 )
2024-10-15 18:22:58 +02:00
andig
3a88cb4add
Add MaxACPower hybrid battery setting ( #16609 )
2024-10-13 19:20:40 +02:00
andig
52a9082c90
Revert "Fronius Wattpilot: re-add ( #15843 )"
...
This reverts commit 9bac4f7a29 .
2024-10-13 18:26:35 +02:00
Ante Karamatić
ee398fe6ad
Enphase: add inverters ( #16625 )
...
Return max value from two sources of production information. This allows using metering provided by either CTs or inverters, while before this commit only CT values were used.
2024-10-13 09:47:00 +02:00
andig
5dd85db476
chore: skip ci tests ( #16620 )
2024-10-12 14:42:53 +02:00
andig
b941f86ef0
SofarSolar: ignore LSE3 modbus errors ( #16618 )
2024-10-12 12:07:16 +02:00
andig
11d2b8b85d
Modbus: add bytes setter ( #16510 )
2024-10-12 11:09:12 +02:00
andig
95cab8df40
chore: align battery control templates ( #16565 )
2024-10-08 14:55:53 +02:00
andig
a8df65f121
Growatt TLX(H): add battery control ( #16560 )
2024-10-08 09:07:48 +02:00
andig
1c7fe2a0b7
Growatt: fix templates
2024-10-08 08:24:21 +02:00
VolkerK62
72b57991a0
Slimmelezer-v2: fix phase power sign ( #16546 )
2024-10-07 13:03:16 +02:00
andig
550ca5a420
PulsarPlus: differentiate by firmware ( #16526 )
2024-10-06 13:57:06 +02:00
andig
8cc3b0f4d2
Allow marking tests to be skipped ( #16528 )
2024-10-06 13:45:38 +02:00
andig
bed11f369c
SofarSolar: clarify battery control ( #16508 )
2024-10-05 12:38:54 +02:00
Michael Geers
6395307a53
eebus: fix duplicate template names ( #16484 )
2024-10-03 18:46:47 +02:00
andig
921837c3e7
Elli: update status ( #16478 )
2024-10-03 16:55:10 +02:00
andig
67e5927078
Kostal Plenticore Gen2: add battery control ( #16414 )
2024-10-03 12:36:04 +02:00
mucki12
0ae27c792f
Huawei Sun2000: increase grid charge power ( #16453 )
...
Die maximal mögliche Ladeleistung des Huawei LUNA liegt bei 10000. Sollte der installierte Huawei LUNA weniger (2500, 5000 oder 7500) unterstützen, wird automatisch dieser maximale Wert gesetzt.
2024-10-03 12:28:52 +02:00
andig
2fa62e12ba
AC Elwa 2: document sponsorship
2024-09-29 14:50:26 +02:00
Andreas Linde
15483ad7a2
Add more EEBUS wallboxes ( #16383 )
...
- Fix a name of one of the Elli Wallboxes
- Add Porsche Wallbox
- Add eSystems and Kontron Solar wallboxes
2024-09-28 00:06:39 +02:00
Andreas Linde
13d862287a
Add Elli Wallbox 2 ( #16375 )
2024-09-27 16:43:57 +02:00
andig
98d9cb0a24
chore: fix typo
2024-09-27 11:46:54 +02:00
SoftCat
35d4bdf42e
Alpha ESS: add battery control ( #16280 )
2024-09-27 10:26:33 +02:00
andig
d53ead0f36
Fronius SolarAPI: prefer modbus ( #16260 )
2024-09-26 16:58:45 +02:00
Philipp Trulson
52864b9dde
E3DC: make credentials required ( #16290 )
2024-09-25 09:39:23 +02:00
andig
6db50af603
SofarSolar: switch battery control ( #16311 )
2024-09-25 08:51:43 +02:00
benesolar
a634a8c4b4
Sunspec Inverter: add single phase grid meters ( #16247 )
2024-09-23 21:35:44 +02:00
andig
f43cee168e
chore: simplify ( #16257 )
2024-09-21 11:24:58 +02:00
andig
b8162aafb8
SofarSolar: add battery discharge control ( #16113 )
2024-09-20 18:30:18 +02:00
andig
7045c10bc7
Sunspec: reset InOutWRte_RvrtTms for battery control ( #16241 )
2024-09-20 16:56:32 +02:00
andig
3eb1ae0c4e
chore: fix type
2024-09-16 10:35:15 +02:00
thebrainkafka
484248ebee
chore: update docs ( #16145 )
2024-09-16 09:13:40 +02:00
andig
62c26ec654
myPV Elwa2: refactor ( #15466 )
2024-09-15 18:51:19 +02:00
andig
81a315928d
chore: fix wording
2024-09-15 16:38:53 +02:00
andig
bab0d67d93
SMA: fix Sunny Boy Storage 1.5/2.0/2.5 ( #16106 )
2024-09-15 14:02:57 +02:00
andig
f3fb1c1ae2
Fronius SolarApi: mark charge mode as not available ( #16121 )
2024-09-15 11:50:20 +02:00
andig
f7b83fa8f5
chore: fix default value
2024-09-15 10:48:15 +02:00
andig
4bbaf0de47
chore: fix error type
2024-09-14 21:30:53 +02:00
andig
213eeafd0b
chore: docs
2024-09-14 21:27:53 +02:00
andig
78b7bfd6c3
SolarMax: add battery discharge control ( #16110 )
2024-09-14 21:00:00 +02:00
andig
5f79df4f0e
Add Wattsonic ( #16104 )
2024-09-14 16:54:43 +02:00
andig
3b3ac4df59
Saj-H2: add battery control ( #15988 )
2024-09-14 14:37:24 +02:00
andig
4fa6f8ada5
Deye Hybrid: add default socs ( #15987 )
2024-09-11 18:45:07 +02:00
andig
9010545249
chore: put grid first ( #15990 )
2024-09-11 18:18:18 +02:00
andig
2d60e6797a
chore: cleanup capacity ( #15989 )
2024-09-11 18:14:49 +02:00
Michael Geers
89fb334b64
docs: fix slimmelezer description
2024-09-09 21:22:17 +02:00