template: cozify products: - brand: Cozify HAN description: generic: Cozify HAN requirements: description: de: Erfordert eine Verbindung zum Cozify HAN Gateway. en: Requires a connection to the Cozify HAN gateway. params: - name: usage choice: ["grid"] - name: host required: true - name: cache advanced: true default: 5s render: | type: custom power: source: http uri: http://{{ .host }}/meter/data cache: {{ .cache }} jq: (.pi[0] - .pe[0]) energy: source: http uri: http://{{ .host }}/meter/data cache: {{ .cache }} jq: (.ic | tonumber) currents: - source: http uri: http://{{ .host }}/meter/data cache: {{ .cache }} jq: .i[0] - source: http uri: http://{{ .host }}/meter/data cache: {{ .cache }} jq: .i[1] - source: http uri: http://{{ .host }}/meter/data cache: {{ .cache }} jq: .i[2] voltages: - source: http uri: http://{{ .host }}/meter/data cache: {{ .cache }} jq: .u[0] - source: http uri: http://{{ .host }}/meter/data cache: {{ .cache }} jq: .u[1] - source: http uri: http://{{ .host }}/meter/data cache: {{ .cache }} jq: .u[2]