uri: 0.0.0.0:7070 # uri for ui interval: 10s # control cycle interval # mqtt message broker mqtt: broker: localhost:1883 # user: # password: # influx database (v1) influx: url: http://localhost:8086 database: evcc # user: # password: # additional menu entries menu: # - title: "Verlauf" # subtitle: "Bezugs- und Einspeiseleistung" # img: "http://..." # link: "http://..." # iframe: "http://..." # push messages messaging: events: start: # charge start event title: Charge started msg: ${loadpoint} started charging in "${mode}" mode stop: # charge stop event title: Charge finished msg: ${loadpoint} finished charging. Charged ${energy:%.1f}kWh in ${duration}. services: - type: pushover app: # app id recipients: - # list of recipient ids - type: telegram token: # bot id chats: - # list of chat ids # meters meters: - name: grid type: default power: # power reading type: mqtt # use mqtt topic: mbmd/sdm1-1/Power # mqtt topic timeout: 10s # don't use older values - name: pv type: default power: type: mqtt topic: mbmd/sdm1-2/Power timeout: 10s # don't use older values - name: battery type: default power: type: mqtt topic: mbmd/sma1-1/Power timeout: 10s # don't use older values - name: charge type: default power: type: script # use script cmd: /bin/sh -c "echo 0" # actual command timeout: 3s # kill script after 3 seconds - name: sma type: sma # SMA Home Manager 2.0 or SMA Energy Meter 30 serial: 1234567890 # Serial number of the device, if this is defined uri is not needed! uri: 192.168.1.4 # IP address of the device, if this is defined serial is not needed! - name: sdm type: modbus model: sdm uri: rs485.fritz.box:23 rtu: true # rs485 device connected using ethernet adapter id: 2 power: Power # default values, optionally override energy: Sum # default values, optionally override - name: e3dc-battery type: default power: type: modbus uri: e3dc.fritz.box:502 id: 1 register: # manual register configuration address: 40070 length: 2 type: holding decode: int32 scale: -1 # reverse direction chargers: - name: wallbe type: wallbe # Wallbe charger uri: 192.168.0.8:502 # ModBus address # legacy: true # enable for older Wallbes with Phoenix EV-CC-AC1-M3-CBC-RCM controller - name: phoenix type: phoenix-emcp # Charger with Phoenix Contact controller uri: 192.168.0.8:502 # ModBus address id: 1 - name: simpleevse-tcp type: simpleevse # Charger with Phoenix Contact controller uri: 192.168.0.8:502 # TCP ModBus address - name: simpleevse-rtu type: simpleevse # Charger with Phoenix Contact controller device: /dev/usb1 # RS485 ModBus device - name: evsewifi type: evsewifi # Charger with Phoenix Contact controller uri: http://192.168.1.4 # SimpleEVSE-Wifi address - name: nrg-1 type: nrgkick-connect # NRGKick Connect charger ip: 192.168.1.4 # IP macaddress: 00:99:22 # MAC address password: # password # - name: nrg-2 # type: nrgkick-bluetooth # NRGKick charger with Bluetooth # macaddress: 00:99:22 # MAC address # pin: # pin - name: go-e type: go-e # go-eCharger uri: http://192.168.1.4 # go-e address - name: keba type: keba # KEBA charger uri: 192.168.1.4:7090 # KEBA address rfid: tag: 765765348 # RFID tag, see `evcc charger` to show tag - name: mcc type: mcc # Mobile Charger Connect (Audi, Bentley, Porsche) uri: https://192.168.1.4 # Mobile Charger Connect address password: # home user password - name: configurable type: default # Configurable charger status: # charger status A..F type: mqtt topic: some/topic1 enabled: # charger enabled state (true/false or 0/1) type: mqtt topic: some/topic2 enable: # set charger enabled state type: script cmd: /bin/sh -c "echo ${enable}" maxcurrent: # set charger max current type: script cmd: /bin/sh -c "echo ${maxcurrent}" vehicles: - name: default type: default title: Default capacity: 50 # kWh charge: type: script # use script cmd: /bin/sh -c "echo 50" # actual command timeout: 3s # kill script after 3 seconds cache: 5m - name: audi type: audi title: Q55 TFSIe capacity: 10 # kWh user: # user password: # password vin: WAUZZZ... cache: 5m - name: bmw type: bmw title: i3 capacity: 65 # kWh user: # user password: # password vin: WBMW... cache: 5m # - name: tesla # type: tesla # title: Model S # capacity: 90 # kWh # clientid: # client id # clientsecret: # client secret # email: # email # password: # password # vin: WTSLA... # cache: 5m # - name: nissan # type: nissan # title: Leaf # capacity: 60 # kWh # user: # user # password: # password # region: NE # carwings region, leave empty for Europe # cache: 5m # - name: renault # type: renault # title: Zoe # capacity: 60 # kWh # user: # user # password: # password # region: de_DE # gigya region # vin: WREN... # cache: 5m # - name: porsche # type: porsche # title: Taycan # capacity: 83 # kWh # user: # user # password: # password # vin: WP... # cache: 5m loadpoints: - name: main # name for logging vehicle: audi charger: wallbe # charger meters: grid: grid # grid meter pv: pv # pv meter battery: battery # battery meter charge: charge # charge meter enable: # pv mode enable behavior delay: 1m # threshold must be exceeded for this long threshold: 0 # minimum export power (W). If zero, export must exceeds minimum charge power to enable disable: # pv mode disable behavior delay: 5m # threshold must be exceeded for this long threshold: 200 # maximum import power (W) guardduration: 10m # switch charger contactor not more often than this (default 10m) maxcurrent: 16 # maximum charge current (default 16A) phases: 3 # ev phases (default 3) sensitivity: 1 # current raise/lower step size (default 10A)