package eebus
|
|
|
|
// EEBUS use case scenario numbers per the respective Use Case Technical Specifications.
|
|
//
|
|
// Spec scenario numbers diverge between use cases (e.g. MPC scenario 1 = active power,
|
|
// MGCP scenario 1 = power factor; MPC scenario 2 = energy, MGCP scenario 2 = active power).
|
|
// Passing the wrong number to IsScenarioAvailableAtEntity gates reads on the wrong feature.
|
|
//
|
|
// Each block mirrors the scenarios registered in the corresponding eebus-go usecase, which
|
|
// in turn matches the EEBus UC TS document.
|
|
|
|
// MGCP — Monitoring of Grid Connection Point (UC TS v1.0.0)
|
|
const (
|
|
MGCPPowerFactor uint = 1 // S1 power factor (cos phi)
|
|
MGCPPower uint = 2 // S2 active power per phase + total
|
|
MGCPEnergyFeedIn uint = 3 // S3 total feed-in energy
|
|
MGCPEnergyConsumed uint = 4 // S4 total consumed energy
|
|
MGCPCurrentPerPhase uint = 5 // S5 phase-specific currents
|
|
MGCPVoltagePerPhase uint = 6 // S6 phase-specific voltages
|
|
MGCPFrequency uint = 7 // S7 frequency
|
|
)
|
|
|
|
// MPC — Monitoring of Power Consumption (UC TS v1.0.0)
|
|
const (
|
|
MPCPower uint = 1 // S1 active power per phase + total
|
|
MPCEnergyConsumed uint = 2 // S2 total consumed energy
|
|
MPCCurrentPerPhase uint = 3 // S3 phase-specific currents
|
|
MPCVoltagePerPhase uint = 4 // S4 phase-specific voltages
|
|
MPCFrequency uint = 5 // S5 frequency
|
|
)
|
|
|
|
// MDT — Monitoring of Domestic Hot Water Temperature (UC TS v1.0.0)
|
|
const (
|
|
MDTTemperature uint = 1 // S1 DHW temperature
|
|
)
|
|
|
|
// LPC — Limitation of Power Consumption (UC TS v1.0.0). Same scenario layout for CS and EG roles.
|
|
const (
|
|
LPCLimit uint = 1 // S1 LoadControl: consumption limit
|
|
LPCFailsafe uint = 2 // S2 DeviceConfiguration: failsafe values
|
|
LPCHeartbeat uint = 3 // S3 DeviceDiagnosis: heartbeat
|
|
LPCElectricalConnection uint = 4 // S4 ElectricalConnection (optional)
|
|
)
|
|
|
|
// LPP — Limitation of Power Production (UC TS v1.0.0). Same scenario layout for CS and EG roles.
|
|
const (
|
|
LPPLimit uint = 1 // S1 LoadControl: production limit
|
|
LPPFailsafe uint = 2 // S2 DeviceConfiguration: failsafe values
|
|
LPPHeartbeat uint = 3 // S3 DeviceDiagnosis: heartbeat
|
|
LPPElectricalConnection uint = 4 // S4 ElectricalConnection (optional)
|
|
)
|
|
|
|
// OPEV — Overload Protection by EV Charging Current Curtailment (UC TS v1.0.1)
|
|
const (
|
|
OPEVObligationLimit uint = 1 // S1 LoadControl + ElectricalConnection
|
|
OPEVChargingState uint = 2 // S2 charging state
|
|
OPEVChargingPlan uint = 3 // S3 charging plan
|
|
)
|
|
|
|
// OSCEV — Optimization of Self-Consumption during EV Charging (UC TS v1.0.1)
|
|
const (
|
|
OSCEVRecommendationLimit uint = 1 // S1 LoadControl + ElectricalConnection
|
|
OSCEVChargingState uint = 2 // S2 charging state
|
|
OSCEVChargingPlan uint = 3 // S3 charging plan
|
|
)
|
|
|
|
// EVCEM — Measurement of Electricity during EV Charging (UC TS v1.0.1)
|
|
const (
|
|
EVCEMPowerPerPhase uint = 1 // S1 phase-specific active power + ElectricalConnection (currents)
|
|
EVCEMPowerTotal uint = 2 // S2 total active power only
|
|
EVCEMEnergy uint = 3 // S3 charging energy summary
|
|
)
|
|
|
|
// EVSOC — EV State of Charge (UC TS v1.0.0 RC1)
|
|
const (
|
|
EVSOCStateOfCharge uint = 1 // S1 state of charge
|
|
)
|