ABB TACW fw ver 1.6.5 adaptions (#4626)
Charger improvements for ABB Terra AC Wallbox with firmware version 1.6.5 (and newer?) from Nov 2022.
!!! Will break compatibility with older firmware - you have to upgrade the firmware to use the charger !!!

    New: Vehicle connection detection outside of an active session
    New: Getting an enabled state outside of an active session now
    New: Setting max current outside of an active session now
    Charger implementation allows to switch modbus protocol (rtu or tcp) now

Firmware 1.6.5 still has some crazy "non-linear" behavior regarding the sent, applied and read-back max current..
2022-11-11 13:08:58 +01:00
..
charger ABB TACW fw ver 1.6.5 adaptions (#4626) 2022-11-11 13:08:58 +01:00
meter SolarEdge: fix modbus config and add rs485 (#4990) 2022-10-31 11:37:40 +01:00
vehicle Add target energy API & UI for vehicles without SoC 2022-10-04 20:08:57 +02:00
common-schema.json Add int valuetype to json schema 2022-10-15 10:13:42 +02:00
defaults-schema.json Add support for Elli chargers (#4207) 2022-09-30 10:52:17 +02:00
defaults.yaml Add support for Elli chargers (#4207) 2022-09-30 10:52:17 +02:00
devices-schema.json Template schema updates 2022-10-08 13:48:29 +02:00
embed.go Template enhancements (#2274) 2022-01-23 15:21:13 +01:00