| definition | ||
| evcc.io | ||
| README.md | ||
Templates folder documentation
Folders
- definition: hold all device templates definitions in yaml files
- charger: all charger templates
- meter: all meter templates
- vehicle: all vehicle templates
- docs: content is generated via
go generate ./...using the above templates for the evcc documentation page to be used
Template Documentation
The following describes each possible element in a yaml file
template
template expects a unique template name for the current device class (charger, meter, vehicle are device classes)
products
products expects a list of products that work with this template.
Each product contains:
brand: company that makes the product or offers the service. No regions, variants, or API names — those, if required for clarity, belong indescription.description: product, service, model, or API name. Expectsgeneric,de,en.
Either brand or description needs to be set. Examples by device class:
- Vehicles —
brandis the make,descriptionthe connected service:brand: Hyundai,description.generic: Bluelinkbrand: Hyundai,description.generic: Bluelink (US)
- Chargers —
brandis the manufacturer,descriptionthe product model:brand: ABL,description.generic: eMH1brand: ABL,description.generic: eMH2brand: Alfen,description.generic: Eve
- Meters —
brandis the manufacturer,descriptionthe product model:brand: ABB,description.generic: A43brand: my-PV,description.generic: AC ELWA 2
- Tariffs —
brandis the service provider,descriptionthe API variant:brand: Electricity Maps,description.generic: Commercial APIbrand: Electricity Maps,description.generic: Free API
- Generic integrations (OSS tools, community projects): omit
brand, put the project name indescription.generic, setgroup: generic. Keep upstream casing (e.g.TeslaFi,ioBroker.bmw,mg2mqtt).
Note: The official website of the manufacturer or service provider is the reference for the exact spelling.
group
group is used to group switchable sockets and generic device support (e.g. SunSpec) templates.
capabilities
capabilities provides an option to define special capabilities of the device as a list of strings.
Possible values:
iso151182: The device supports communicating via ISO 15118-2.mA: The device supports granular (milliamp) current control.rfid: The device supports RFID.1p3p: The device supports 1P/3P phase switching.battery-control: The device supports battery control.meter: The device has a built-in energy meter.dim: The device supports EnWG §14a dimming.curtail: The device supports EEG §9 curtailment.
capabilities can be set at two levels:
- Template level (next to
template): applies to every product. - Product level (under a
productsentry): applies to that product only.
Both levels are merged, not overwritten: template-level capabilities are appended to each product's own list. A product cannot remove an inherited capability, and duplicates are rejected, so do not repeat a template-level capability on a product.
Example (all products get 1p3p; only the second product additionally gets meter):
template: demo-charger
capabilities: ["1p3p"]
products:
- brand: Demo
description:
generic: Basic
- brand: Demo
description:
generic: Plus
capabilities: ["meter"] # effective: ["meter", "1p3p"]
requirements
requirements provides an option to define various requirements / dependencies that need to be setup
evcc
evcc is a list of evcc specific system requirements
Possible Values:
sponsorship: If the device requires a sponsorship tokeneebus: If the device is accessed via the EEBus protocol and thus requires the corresponding setupmqtt: If the device a MQTT setup
description
description expects language-specific texts via de, en to provide specific things the user has to do, e.g. minimum firmware versions or specific hardware setup requirements.
Markdown formatting:
- The content can be multiline
- The content supports Markdown formatting
- External URLs should always use Markdown link format with the hostname as display text:
[docs.example.com](https://docs.example.com/path/to/page). This provides clear context while keeping the text readable. - Omit
www.from the display text:[example.com](https://www.example.com/path) - GitHub URLs use
github.com/user/repoas display text:[github.com/user/repo](https://github.com/user/repo) - Use code formatting
`text`for technical identifiers, tokens, configuration values, and entity patterns - Placeholder and example URLs (IP addresses, hostnames, device endpoints) should also use code formatting:
`http://<charger-host>:8000/semp`,`ws://<evcc-host>:8887/` - Use angle-bracket placeholders for device addresses:
<evcc-host>,<charger-host>,<meter-host>,<inverter-host> - Use only plain ASCII quotes (
”,’) — never typographic/curly quotes (”,”,„,’,’) - Use bold formatting
**text**sparingly and only for important warnings or critical information
Example:
en: |
Requires `hcaptcha` token from [developer.example.com](https://developer.example.com/tokens).
Configure the SEMP base URL (`http://<charger-host>:8000/semp`).
Set the backend URL to `ws://<evcc-host>:8887/`.
**Attention**: Token is only valid for 2 minutes.
caveats
caveats documents known limitations or unreliable behaviour of a device that otherwise works. This is distinct from requirements.description, which covers setup steps the user must perform.
It is a list, so a device can have multiple caveats. Each entry has a language-specific description (de, en) and a link.
Guidelines:
- Add one entry per distinct problem (e.g. "unreliable meter" and "occasional reboots" are two entries); don't list the same problem twice.
- Keep descriptions as concise as possible while still understandable.
- Use factual wording describing the observed behaviour.
- Always add a
linkto the single issue or discussion that best documents the problem, so the situation can be re-verified later. It is technically optional, but omitting it should be a rare exception. - The
descriptionfollows the same Markdown formatting rules asrequirements.descriptionabove.
Example:
caveats:
- description:
de: Phasenumschaltung deaktiviert sich gelegentlich von selbst.
en: Phase switching occasionally disables itself.
link: https://github.com/evcc-io/evcc/issues/21708
auth
auth defines OAuth authentication configuration for devices that require user authorization. When specified, the UI OAuth flow and token management are handled automatically. The auth endpoint is called when all required parameters are filled and is re-called on every parameter change.
type
type specifies the OAuth provider type. This must reference a dedicated OAuth implementation.
Available types: homeassistant, ford-connect, viessmann, cardata, volvo-connected
params
params is a list of parameter names (from the params section) that are required for the OAuth configuration. These parameters will be passed to the authentication provider when initiating the OAuth flow. Once all listed parameters have values, the authorization is prepared and the UI displays a redirect link to the external service and device code (if applicable). The preparation is re-triggered whenever any parameter value changes.
Example:
auth:
type: viessmann
params: [clientid, redirecturi, gateway_serial]
params
params describes the set of parameters the user needs to provide a value for.
preset
preset reference value of a predefined params set defined in parambaselist.yaml, so these params don't need to be redefined in each template. The example and default values for each predefined value can be overwritten.
name
name expects a name for the parameter, which will be used in the render section to reference the param and provide the user entered value.
Note: There a few default name values with specific internal meaning and consequences!
Predefined name values:
usage: specifies a list of meter classes, the device can be used for. Possible values aregrid,pv,battery, andchargermodbus: specifies that this device is accessed via modbus. It requires thechoiceproperty to have a list of possible interface values the device provides. These values can bers485andtcpip. The command will use either to ask the appropriate questions and settings. Therendersection needs to include the string{{include "modbus" .}}in all places where the configuration needs modbus settings.
Modbus Options
id: Device specific default for modbus IDport: Device specific default for modbus TCPIP portbaudrate: Device specific default for modbus RS485 baudratecomset: Device specific default for modbus RS485 comset
description
description allows to define user friendly and language specific names via de, en, generic
dependencies
dependencies allows to define a list of checks, when this param should be presented to the user, if it should be only in special cases
name
name referenced the param name value
check
check defines which kind of check should be performed
Possible values:
empty: if thevalueof the referencedparamnameshould be emptynotempty: if thevalueof the referencedparamnameshould be NOT emptyequal: if thevalueof the referencedparamnameshould match the value of thevalueproperty
value
value property is used in the equal check
required
required: true defines if the user has to provide a value. Default is false
mask
mask: true defines if the user input should be masked in the UI (password field). Used for sensitive credentials like passwords, tokens, and API keys that should be hidden from view. Default is false.
Note: Cannot be used together with private.
private
private: true marks a parameter as containing personal data (e.g., email addresses, VIN numbers, MAC addresses, locations). This data will be redacted from bug reports and diagnostic information but is visible in the UI. Default is false.
Examples of private data: usernames, email addresses, VIN, URI, MAC addresses, latitude/longitude, serial numbers
Note: Cannot be used together with mask.
default
default defines a default value to be used, which will be pre-filled in the configuration UI.
example
example provides an example value, so the user can get an idea of what is expected and what to look out for
type
type allows to define the value type to let the UI verify the user provided content
Possible values:
string: for string values (default)bool: fortrueandfalsevalueschoice: for a selection from predefined options (defined inchoiceproperty)chargemodes: for a selection of charge modes (Off,Now,MinPV,PV), includingNonewhich results in the param not being setduration: for duration values (e.g.,5m,1h30m,10s)float: for floating point numbersint: for integer valueslist: for a list of strings (newline-separated in textarea), e.g., used for defining a list ofidentifiersfor vehicles
choice
choice defines the list of possible values when type: choice is used. The user can select one value from this list via a dropdown.
Format: Array of strings
Example:
- name: schema
type: choice
choice: ["https", "http"]
default: https
- name: channel
type: choice
choice: ["general", "feedIn", "controlledLoad"]
required: true
advanced
advanced: true marks a parameter as advanced. Advanced parameters are hidden by default in the UI and can be expanded by the user. Mostly used for non-required params that are meant for users with advanced needs and knowledge.
help
help expects language specific help texts via generic (language independent), de, en
service
service specifies an API endpoint that provides dynamic data or suggestions for this parameter during configuration. When set, the UI will call this service to provide auto-completion or pre-populated options to the user.
Format: service-name/endpoint or service-name/endpoint?param1={param1}¶m2={param2}
Parameters from other params can be referenced using {param-name} syntax, which will be replaced with the user's input for that parameter. The endpoint will only be called once the user has entered values for all referenced parameters. The endpoint is called every time a referenced parameter value changes.
UI behaviour:
Service endpoints must return an array of strings (e.g., ["value1", "value2"]). These values are shown as suggestions, not strict selections - users can always enter custom text values. The UI handles service responses differently based on the parameter configuration and response content:
-
Auto-fill (prepopulation): If the service returns exactly one value, the parameter is required, and the field is currently empty, the value will be automatically filled into the field.
-
Dropdown suggestions: In all other cases (multiple values, non-required parameter, or field already has a value), the returned values are shown as a dropdown/datalist for the user to select from or ignore.
-
Empty response: If the service returns an empty array or no data, the field remains a regular text input.
Available services:
-
Hardware
hardware/serial: Lists available serial ports on the system -
Modbus
modbus/read?...: Reads a value from a modbus register (for validation/testing)The
modbusservice supports a special{modbus}parameter that will be automatically expanded to the appropriate connection parameters based on the user's modbus configuration:# Template definition - name: voltage service: modbus/read?address=100&type=holding&{modbus} # Expanded for TCP connection: # modbus/read?address=100&type=holding&uri=192.168.1.10:502&id=1 # Expanded for RTU connection: # modbus/read?address=100&type=holding&device=/dev/ttyUSB0&baudrate=9600&id=1 -
Home Assistant
homeassistant/instances: Auto-discovers Home Assistant instances on the networkhomeassistant/entities?uri={uri}&domain=sensor: Lists entities from a Home Assistant instance filtered by domain(s). Multiple domains can be comma-separated (e.g.,domain=sensor,binary_sensorordomain=number,input_number)
render
render contains the internal device configuration. All param name values can be used as a template variable, e.g. {{ .host }} for a param named host. The content is a go template, so all of go template feature can be used, e.g. {{- if ... }} statements, etc.