30 lines
908 B
YAML
30 lines
908 B
YAML
## external control via relay
|
|
|
|
#type: relay
|
|
#maxPower: 4200 # limit loadpoints to 4.2 kW total
|
|
#limit: # limit signal, plugin
|
|
# source: mqtt
|
|
# topic: hems/limit/status # 0/false = normal, 1/true = limit active
|
|
|
|
## external control via FNN Steuerbox
|
|
|
|
#type: fnn
|
|
#maxDimPower: 4200 # limit consumption to 4.2 kW while dimmed (W4)
|
|
#maxCurtailPower: 10000 # installed PV power, base for curtailment steps (W3/S1/S2)
|
|
#w4: # dim signal, plugin
|
|
# source: mqtt
|
|
# topic: hems/w4/status # 0/false = normal, 1/true = limit active
|
|
#w3: # curtail to 0% signal, plugin
|
|
# source: mqtt
|
|
# topic: hems/w3/status
|
|
#s2: # curtail to 30% signal, plugin
|
|
# source: mqtt
|
|
# topic: hems/s2/status
|
|
#s1: # curtail to 60% signal, plugin
|
|
# source: mqtt
|
|
# topic: hems/s1/status
|
|
|
|
## external control via EEBus
|
|
|
|
#type: eebus # general EEBus setup (cert gen) required
|
|
#ski: "1234-5678-90AB-CDEF" # SKI of control box (grid operator)
|