Co-authored-by: andig <andi@evcc.io> Co-authored-by: andig <cpuidle@gmail.com> Co-authored-by: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
51 lines
1.2 KiB
YAML
51 lines
1.2 KiB
YAML
template: enphase-modbus
|
|
products:
|
|
- brand: Enphase
|
|
description:
|
|
generic: IQ Gateway (Modbus)
|
|
requirements:
|
|
description:
|
|
en: |
|
|
Requires Enphase support to enable modbus functionality on IQ Gateway.
|
|
de: |
|
|
Erfordert Enphase-Unterstützung, um die Modbus-Funktionalität auf dem IQ Gateway zu aktivieren.
|
|
params:
|
|
- name: usage
|
|
choice: ["pv"]
|
|
- name: modbus
|
|
choice: ["tcpip"]
|
|
id: 1
|
|
render: |
|
|
type: custom
|
|
# sunspec model 701 (DER AC Measurement)
|
|
{{- if eq .usage "pv" }}
|
|
power:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
value: 701:W
|
|
energy:
|
|
source: sunspec
|
|
{{- include "modbus" . | indent 2 }}
|
|
value: 701:TotWhInj
|
|
scale: 0.001
|
|
currents:
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value: 701:AL1
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value: 701:AL2
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value: 701:AL3
|
|
voltages:
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value: 701:VL1
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value: 701:VL2
|
|
- source: sunspec
|
|
{{- include "modbus" . | indent 4 }}
|
|
value: 701:VL3
|
|
{{- end }}
|